Vulcan-Hart MSA48 ASA48, MSA72 ASA72, AGM60 Cutaway View, Pilot Lighting Procedure 900RX Models

Page 12

PILOT LIGHTING PROCEDURE – 900RX MODELS

1.Turn the griddle shut-off valve to the OFF position (See Fig.6 on page 9). Wait 5 minutes to allow any gas that may have accumulated in the burner compartment to escape.

2.Turn the griddle shut-off valve to the ON position (See Fig. 5 on page 9).

3.Push and hold the power switch in the ON position. The switch will illuminate and you will hear a “clicking” sound.

4.While continuing to hold the power switch in the ON position, depress and hold the red button on the pilot safety valve while the electric igniters light the corresponding pilots. You will have to monitor the pilot burners through the pilot sight holes. The pilot burners are aligned with the red buttons on the pilot safety valves . The pilot burners are inset 12” from the front of the unit.

pilot burner

pilot sight hole

pilot safety valve button

power switch

pilot cutout

12”

 

Fig. 11

griddle shut-off valve

CUTAWAY VIEW

5.Watch for the pilot burners to ignite. When the gas at the pilot has been burning for about 45 seconds, release the corresponding red button on the pilot safety valve. If the pilot does not remain lit, repeat the procedure allowing more time before releasing the button. The amount of time necessary to hold the safety valve button will increase at the initial installation of the unit and if the main gas supply has been turned off for a long period of time. It may be necessary to adjust the pilot valve to increase gas to the pilot.

6.Repeat steps until all pilots are lit.

7.The pilot burners can be lit manually in the event of a failure of the electronic ignition system. If

this happens, repeat steps 1-5 without holding the power switch in the ON position. You will have to reach under the front of the unit and through the pilot cutout to ignite the pilots with an outside ignition source(such as a lit taper, etc.) while again depressing the corresponding red button.

8.If after completing steps 1 – 7 and the pilot does not light, turn the griddle shut-off valve to the OFF position (See Fig. 6 on page 9) and contact an authorized service agency.

-12 -

Image 12
Contents Heavy Duty GAS Griddles For Your Safety Important for Your SafetyTable of Contents Installation Model Number of Burners BTU/hr Input RatingUnpacking LocationInstallation Codes and Standards Griddles Mounted on Stands with CastersTesting the GAS Supply System Flue ConnectionsStands GAS ConnectionsGAS Pressure Regulator Installation Electrical Connections 900RX ModelsOperation Before First USESeasoning the Griddle Controls 900RX ModelsOFF Controls MSA and ASA Models Controls AGM Models Pilot Lighting Procedure 900RX Models Cutaway ViewPilot Lighting PROCEDURE- MSA and ASA Models Pilot Lighting Procedure AGM Models Using the Griddle Zone CookingZone 300F 350F 400FCleaning the Griddle Cleaning a Chrome Griddle Plate After Each USEAfter Each USE Once PER DAYAdjustments CALIBRATION-900RX and MSA ModelsPilot Adjustment LevelingShutdown of Griddle MSA and ASA Models Shutdown of Griddle with Standing Pilot System AGM ModelsExtended Shutdown ALL Models Maintenance Service and Parts InformationLubrication VentTroubleshooting ProblemPossible Causes Accessory Installation Side View Front View Page AGM48 AGM72 AGM60 AGM36 AGM24 MSA48 ASA72 Sécurité DE Mesure Importantes Sécurité DE MesuresMatières DES Table Emplacement DéballageRating Input BTU/hr Burners of Number Model Normes ET D’INSTALLATION Codes AvisRoulettes DE Muni Support UN SUR Montée Frire À Plaque GAZ DU Branchement Supports’ÉVACUATION Système Régulateur D’UN Installation ET GAZ DU Pression Fait soit neFiche Avertissement900RX Modèles Commandes FonctionnementFermé Ouvert ASA ET MSA Modèles Commandes AGM Modèles Commandes 10 .Fig900RX Modèles Veilleuse LA DE D’ALLUMAGE Procédure 11 .Fig12 .Fig ASA ET MSA Modèles Veilleuse LA DE D’ALLUMAGE Procédure13 .Fig AGM Modèles Veilleuse LA DE D’ALLUMAGE ProcédureProduit Cuisson DE ZoneJour PAR Fois UNE .CHROMÉE Plaque LA DE Surface LA SUR Frire Semaine PAR Fois UNERéglages MSA ET 900RX MODÈLES-ÉTALONNAGE900RX Modèles Électrique ’ALLUMAGE Système Avec Chauffante Plaque LA DE Fermeture14 .Fig Veilleuse LA DE RéglageModèles Tous Prolongée Fermeture Entretien ’ÉVACUATION ConduitLubrification Dépannage Possibles CausesProblème Complice DE Installation ProfilDevant DE VUE Profil Remarques

AGM48, AGM24, AGM36, AGM72, AGM60 specifications

Vulcan-Hart is a well-respected name in the commercial kitchen equipment industry, known for its high-quality cooking appliances. Among their extensive product line, the MSA series stands out, featuring models such as the MSA72 ASA72, MSA60 ASA60, MSA48 ASA48, MSA24 ASA24, and MSA36 ASA36. These models are designed to meet the demanding needs of professional kitchens while ensuring reliability, efficiency, and performance.

The MSA series includes a range of sizes, from the expansive MSA72 ASA72 with 72 inches of cooking surface to the compact MSA24 ASA24 designed for smaller kitchen spaces. This variety allows kitchen operators to select the equipment that best fits their operational needs without sacrificing quality.

Each model is equipped with innovative technologies designed to enhance cooking efficiency. These units feature durable stainless steel construction, which not only provides a sleek and professional appearance but also ensures longevity and ease of cleaning. The cooking surfaces are crafted for optimal heat retention and distribution, allowing for even cooking across the entire surface area, which is essential in high-volume environments.

The MSA series is equipped with powerful burners that provide precise temperature control, enabling chefs to execute a wide range of cooking techniques with ease. Whether sautéing, frying, or simmering, these burners deliver consistent heat, allowing for superior culinary results. Additionally, the models incorporate safety features such as flame failure devices that automatically shut off gas supply in case of flame loss, ensuring a safe working environment.

Another notable characteristic of the MSA series is their user-friendly design. Features like intuitive knobs and controls facilitate easy operation, even during the busiest service periods. The models are also designed for straightforward maintenance, with removable parts that allow for efficient cleaning and upkeep.

Overall, the Vulcan-Hart MSA series, including the MSA72 ASA72, MSA60 ASA60, MSA48 ASA48, MSA24 ASA24, and MSA36 ASA36, embodies a blend of performance, safety, and user-centric design. With their robust construction and advanced cooking technologies, these models are an excellent choice for commercial kitchens seeking to enhance productivity and culinary excellence. Investing in Vulcan-Hart equipment allows operators to provide consistent quality while streamlining their cooking processes.