| TROUBLESHOOTING | ||
| OVEN |
|
|
|
|
|
|
| PROBLEM | PROBABLE CAUSES | |
|
|
|
|
| Too Much Bottom Heat | Insufficient heat input. (Call for Service) | |
|
| Overactive flue. (Call for Service) | |
| Uneven Bake | Too low temperature. | |
|
| Improper operation. | |
| Side Burning | Improper bypass setting. (Call for Service) | |
|
| Fluctuating gas pressure. (Call for Service) | |
|
|
|
|
| Too Much Top Heat | Too high temperature. | |
|
| Faulty ventilation. (Call for Service) | |
|
| Excessive heat input. (Call for Service) | |
|
| Thermostat needs calibration. (Call for Service) | |
|
|
|
|
| Uneven Bake - Side to Side | Range not level side to side. | |
|
| Oven burner, bottom or baffles improperly installed. | |
|
|
|
|
| Pulling to Edge of Pan | Warped pans. | |
|
| Oven not level. | |
| Uneven Bake - Front to Rear | Overactive flue. (Call for Service) | |
|
| Range not level front to back. | |
|
| Door not closing properly. (Call for Service) | |
|
|
|
|
| Too low temperature. | ||
|
| Too long baking time. | |
|
| Thermostat calibration. (Call for Service) | |
|
|
|
|
| Pilot Outage | Gas supply not sufficient. (Call for Service) | |
|
| Pilot flame too low. (Call for Service) | |
|
| Restriction in pilot orifice. (Call for Service) | |
|
| Malfunctioning check valve. (Call for Service) | |
|
| CONVECTION OVEN MODELS ONLY: | |
|
| Cavity leaking. (Call for Service) | |
|
| Gasket problems. (Call for Service) | |
|
| Snorkel tube blocked. | |
|
| Blower running backward. (Call for Service) | |
|
|
|
|
| Excessive Meat Shrinkage | Roasting temperature too high. | |
|
|
|
|
| TOP BURNER OPERATION |
|
|
|
|
|
|
| PROBLEM | PROBABLE CAUSES |
|
| Improper Burner Combustion | Improper use, allowing improper ventilation. |
|
| Excessive Valve Handle Temperatures | Poor door fit. (Call for Service) |
|
| Sticking Top Burner Valves | Oven door left open. |
|
|
|
|
|
| Poor Ignition | Insufficient gas input. (Call for Service) |
|
|
| Poor |
|
|
| Restriction in pilot orifice. (Call for Service) |
|
|
| Restriction in main burner ignition port. (Call for Service) |
|
|
| Restriction in control valve. (Call for Service) |
|
|
| Restriction in gas orifice. (Call for Service) |
|
|
|
|
|
|
|
|
|
FORM 35634 | – 24 – | PRINTED IN U.S.A. |