Snorkel® Ranges must not be included in
The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 35" (889 mm) is required.
The range(s) must be installed so that the flow of combustion and ventilation air will not be obstructed. Adequate clearance for air openings into the combustion chamber(s) must be provided. Make sure there is an adequate supply of air in the room to allow for combustion of the gas at the burners.
INSTALLATION CODES AND STANDARDS
Your Vulcan range(s) must be installed in accordance with:
In the United States:
1.State and local codes.
2.National Fuel Gas Code,
3.National Electrical Code
In Canada:
1.Local codes.
2.CSA B149.1 Natural Gas and Propane Installation Code.
3.CSA C22.1 Canadian Electrical Code.
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.
ASSEMBLY |
|
Ranges Mounted on Casters |
|
Ranges mounted on casters must use a flexible connector (not supplied |
|
by Vulcan) that complies with the Standard for Connectors for Movable |
|
Gas Appliances, ANSI Z21.69 • CSA 6.16 and a |
|
device that complies with the Standard for |
|
for Use With Gas Fuel, |
|
means must be provided to limit movement of the appliance without |
|
depending on the connector and the |
|
associated piping to limit appliance movement. Attach the restraining |
|
device at the rear of the range as shown in Fig. 1. | Fig. 1 |
If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect this restraint prior to turning the gas supply on and returning the range to its installation position.
Separate instructions for installing casters to the range are included with the casters.
– 5 –