Installation Options
COOKTOP INSTALLATION OVER A 30″ MONOGRAM SINGLE OVEN,
MODEL ZET1 OR ZET938
These cooktops may be installed over the Monogram ZET1 or ZET938 single oven. Both the cooktop and the oven must be installed according to each specific installation instruction.
–Allow 4″ Min. clearance from the top of the countertop to the top of the oven cutout.
POWER SUPPLY
The oven requires a separate, properly grounded
20 Amp,
Cooktop | ″ | |
25 | ||
| ||
|
36″
4″ min. countertop
height
28-5/8″ max.
23-1/2″ min.
C
L
C | 25″ |
L |
|
Use two 2x4’s or equivalent runners spaced 25″ centerline to centerline in the opening and flush with top of toekick.
Or elevate the oven floor to desired height. The support must be level, rigidly mounted and capable of supporting 200 lbs.
Use a 36″ or wider base cabinet.
•For best appearance, the cooktop should be centered over the oven.