GE ZGU385N, ZGU385L Installation Instructions for LP to Natural Gas Conversion

Page 18

Installation Instructions for LP to Natural Gas Conversion

2 CHANGE BURNER ORIFICES (cont.)

IMPORTANT: Orifices must be located exactly as shown. Carefully read and observe each orifice label for correct location.

SIMMER

 

 

 

 

 

 

 

 

The 34SL and

 

 

 

 

 

 

 

 

 

 

ORIFICES

 

 

 

 

 

 

 

 

51SN are for all

 

 

 

 

 

 

 

 

 

 

 

five burners.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3ADJUST BURNER FLAMES

A.Turn all burners on highest setting and check the flames. They should be blue (no yellow tipping) when using natural gas. Foreign particles in the gas line may cause an orange flame at first, but this will soon disappear.

B.Turn the cooktop burner knob to “LO” while observing the flame.

Adjust the setting of the upper row of flames using the valve bypass screw as follows:

Adjustments must be made with two other burners in operation on a medium setting. This prevents the upper row of flames from being set too low, resulting in the flame being extinguished when other burners are turned on.

C.To adjust the flame, remove the knobs. Insert a screwdriver through the access hole in valve shaft as shown.

MAIN

ORIFICES

108XL

190XN

 

84XL

 

 

138XN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

84XL 148XN

• If the flames were too small or fluttered, open the valve

more than the original setting.

• If the flames blew away from the burner, close the valve

more than the original setting.

D. Make the adjustment by slowly turning the screw until

flame appearance is correct.

E. Testing Flame Stability:

Test 1 – Turn the knob from “HI” to “LO” quickly.

If the upper row of flames goes out at this setting,

increase the flame size and test again.

Test 2 – With the burner on “LO”, open and close the

cabinet door under the cooktop. If the flame is

extinguished by the air currents created by the

door movement, increase the flame height and

test again.

NOTE: When the burner is on the “SIM” setting, the upper

C.Install the proper orifices in the exact locations as noted in the illustrations above.

D.Return the LP gas orifices to the bracket and reattach the bracket and the instruction sheet to the pressure regulator using the screw removed previously.

E.Replace the burner bases, heads, caps and top grates.

row of flames will go out.

F. Flame Recheck:

After the adjustment is made, turn all burners off. Ignite

each burner individually. Observe the flame at the “HI”

position. Rotate the knob to the lowest setting and be

sure that the flame size decreases as the knob is

rotated counterclockwise.

Once the conversion is complete and checked ok,

fill out the conversion sticker and include your name,

organization and date conversion was made. Apply

the sticker near the cooktop gas inlet opening to

alert others in the future that this appliance has been

converted. If converting back to the original gas, please

remove the sticker so others know the appliance is set

to use its original gas.

18

Image 18
Contents Questions? Call 800.GE.CARES La section française commence à laBefore YOU Begin Safety InformationFor Your Safety What to do if YOU Smell GASContents Electrical RequirementsModels Available Installation PreparationTools YOU will Need For Installation Parts IncludedInstallation Above Cabinet Drawers Installation OptionsCooktop and ZVB36 Downdraft Vent Combination Installation Advance PlanningPRE-INSTALLATION Checklist Dimensions and Clearances Gas supply Power Supply LocationsOptional Combination Installations Electrical supplyInstall Pressure Regulator Installation InstructionsInstall the Cooktop Connect ElectricalAssemble BURNERS, Check Ignition Check ignitersBurners should be checked frequently Operation Checklist″ to EdgesInstallation Options ″ gap 23-5/16″total flat surface required at center4 ″ Dim. aZTD910 28-1/2″ ZKD910 25-1/2″ 36″ ″ min. countertop Height Model ZET1 or ZET938Oven requires a separate, properly grounded 28-5/8″max 23-1/2″minTools YOU will Need for Conversion Safety InformationAdjust the Regulator Change Burner OrificesAdjust Burner Flames Convert LP Gas Model ZGU385LSMSS to Natural Gas Operation Installation Instructions for LP to Natural Gas Conversion Pour Votre Sécurité Information de la sécuritéAvant DE Commencer CI QUE Vous Devez Faire SI Voussentez LE GAZInformation de la sécurité Avertissement Débranchez Besoins D’ÉLECTRICITÉContenu Pièces Comprises Préparation à l’installationModèles Disponibles Matériaux Dont Vous Pourriez Avoir BesoinInstallation au-dessus des tiroirs des armoires Options D’INSTALLATIONInstallation de la combinaison four simple ZET1 ou ZET938 Planification AvancéeCollé sur la face Liste DE Vérification DE PRÉ-INSTALLATIONEmballage MousseDimensions ET Dégagements Alimentation de gaz Emplacements DE L’ALIMENTATION DE GAZInstallations de combinaison en option 30,5 cm 12 poAvertissement ne réutilisez Instructions d’installationInstallez LE Régulateur DE Pression suite Avertissement n’utilisezAvertissement allumer Vérifiez les allumeursListe DE Vérification Brûleur de la Mm surface de cuisson 1/4 poLes brûleurs doivent être régulièrement vérifiés Options d’installation Surface DE CUISSON-SPÉCIFICATIONS D’INSTALLATIONDim. a 30 PO, Modèle ZET1 OU ZET938 Changez LES Orifices DES Brûleurs Renseignements SUR LA SécuritéOutils Nécessaires Pour LA Conversion EncolurePlus la valve qu’à sa position initiale Ajustez LA Flamme DU BrûleurQue sa position initiale Tester la stabilité de la flammeConvertir le modèle du gaz PL ZGU385LSMSS au gaz naturel Ajustez LA Flamme DU Brûleur GE Consumer & Industrial