GE ZGU385L, ZGU385N Installation Instructions, Install the Cooktop, Install Pressure Regulator

Page 9

Installation Instructions

1INSTALL THE COOKTOP

A.Remove the screws on the sides of the cooktop burner box. Use those screws to attach the side mounting brackets.

B.Insert the cooktop centered into the cutout opening. Make sure the front edge of the countertop is parallel to the cooktop.

Check clearances at the front, back and sides.

Cooktop

Secure the hold-down bracket to the cabinet sides with screws.

2 INSTALL PRESSURE REGULATOR

WARNING: Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use new flexible connectors when installing a gas appliance.

To reduce the possibility of gas leaks, apply teflon tape or a thread compound approved for use with LP or Natural gases to all threaded connections.

A.Screw the regulator onto the burner box bottom pipe connection. Make sure the top of the regulator is facing toward the cabinet front, and the arrow on the back of the regulator points to the cooktop.

 

To cooktop

 

Rear view

Pressure

of

regulator

regulator

(note

 

 

direction

 

of arrow)

 

Electrical outlet 12

Shut-off

below countertop

 

valve

 

2INSTALL PRESSURE REGULATOR (cont.)

Burner Box

90º Elbow

OPTION: You can install a 90º elbow (not supplied) onto the gas inlet and route the gas connections to avoid interference when installed over an oven, with a downdraft vent, a warming drawer or other cabinetry features.

B. Complete the connection between the regulator and the shut-off valve.

C. Before testing for leaks, make sure all burner knobs are in the OFF position.

After connecting the cooktop to gas, check

system for leaks with a manometer. If a manometer is not available, turn the gas supply on to the cooktop and use a liquid leak detector at all

joints and connections to check for leaks.

Tighten all connections if necessary to prevent gas leakage in the cooktop or supply line.

WARNING: Do not use a flame to check for leaks.

Disconnect the cooktop and its individual shut-off valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig (3.5 kPa).

Isolate the cooktop from the gas supply piping system by closing its individual shut-off valve during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).

3CONNECT ELECTRICAL

Check to be sure the receptacle is properly grounded.

Plug in the power cord.

9

Image 9
Contents La section française commence à la Questions? Call 800.GE.CARESFor Your Safety Safety InformationBefore YOU Begin What to do if YOU Smell GASElectrical Requirements ContentsTools YOU will Need For Installation Installation PreparationModels Available Parts IncludedCooktop and ZVB36 Downdraft Vent Combination Installation Installation OptionsInstallation Above Cabinet Drawers Advance PlanningPRE-INSTALLATION Checklist Dimensions and Clearances Optional Combination Installations Power Supply LocationsGas supply Electrical supplyInstall the Cooktop Installation InstructionsInstall Pressure Regulator Connect ElectricalCheck igniters Assemble BURNERS, Check Ignition″ to Operation ChecklistBurners should be checked frequently Edges″ gap 23-5/16″total flat surface required at center Installation Options4 ″ Dim. aZTD910 28-1/2″ ZKD910 25-1/2″ Oven requires a separate, properly grounded Model ZET1 or ZET93836″ ″ min. countertop Height 28-5/8″max 23-1/2″minAdjust the Regulator Safety InformationTools YOU will Need for Conversion Change Burner OrificesAdjust Burner Flames Convert LP Gas Model ZGU385LSMSS to Natural Gas Operation Installation Instructions for LP to Natural Gas Conversion Avant DE Commencer Information de la sécuritéPour Votre Sécurité CI QUE Vous Devez Faire SI Voussentez LE GAZInformation de la sécurité Avertissement Débranchez Besoins D’ÉLECTRICITÉContenu Modèles Disponibles Préparation à l’installationPièces Comprises Matériaux Dont Vous Pourriez Avoir BesoinInstallation de la combinaison four simple ZET1 ou ZET938 Options D’INSTALLATIONInstallation au-dessus des tiroirs des armoires Planification AvancéeEmballage Liste DE Vérification DE PRÉ-INSTALLATIONCollé sur la face MousseDimensions ET Dégagements Installations de combinaison en option Emplacements DE L’ALIMENTATION DE GAZAlimentation de gaz 30,5 cm 12 poInstallez LE Régulateur DE Pression suite Instructions d’installationAvertissement ne réutilisez Avertissement n’utilisezVérifiez les allumeurs Avertissement allumerListe DE Vérification Brûleur de la Mm surface de cuisson 1/4 poLes brûleurs doivent être régulièrement vérifiés Surface DE CUISSON-SPÉCIFICATIONS D’INSTALLATION Options d’installationDim. a 30 PO, Modèle ZET1 OU ZET938 Outils Nécessaires Pour LA Conversion Renseignements SUR LA SécuritéChangez LES Orifices DES Brûleurs EncolureQue sa position initiale Ajustez LA Flamme DU BrûleurPlus la valve qu’à sa position initiale Tester la stabilité de la flammeConvertir le modèle du gaz PL ZGU385LSMSS au gaz naturel Ajustez LA Flamme DU Brûleur GE Consumer & Industrial