GE ZGU385N installation instructions Convert LP Gas Model ZGU385LSMSS to Natural Gas Operation

Page 17

Installation Instructions

Convert LP Gas Model ZGU385LSMSS to Natural Gas Operation

SAFETY INFORMATION

The pressure regulator and burner orifices are set for Liquid Propane (LP) gas operation.

To convert this cooktop from LP gas operation to natural gas operation, the regulator and burner orifices must be converted. Natural gas burner orifices are attached to the regulator.

CAUTION — The cooktop, as shipped from the factory, is set for use with its intended gas. If you wish to use your cooktop with the alternate gas, you must first replace the orifices and convert the pressure regulator.

WARNING — This conversion must be

1ADJUST THE REGULATOR

A.Disconnect all electrical power, at the main circuit breaker or fuse box.

B.Shut off the gas supply to the cooktop by closing the manual shut-off valve.

C.Adjust the pressure regulator by the following instructions:

Unscrew the cap.

Place your thumb against the flat side of the spring retainer and press down to remove the retainer.

Carefully look at the spring retainer to locate the NAT or LP position.

Cap Gasket

performed by a qualified installer or gas supplier in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion.

CAUTION — The following adjustments must

LP

NAT

LP

NAT

NAT.

position

NAT

LP

 

Spring

NAT

retainer

LP

 

L.P./propane position

OFF FOR

DOWN

be made before turning on the burner. Failure to do so could result in serious injury. Be sure pressure regulator has been converted as described in Step 1.

TOOLS YOU WILL NEED FOR

CONVERSION

Crescent wrench

7mm nutdriver

 

Small flat-head

Safety glasses

screwdriver

(2 to 2.4 mm or

 

3/32tip size,

 

60 mm long)

Pressure regulator

Turn the spring retainer over so that the desired gas is showing on the bottom.

Snap the retainer back into position.

Screw the cap back onto the regulator.

2 CHANGE BURNER ORIFICES

INSTALLATION TIP: First remove all

Burner cap

orifices and then start replacing them.

 

This will help to prevent the possibility

 

that some may not be replaced.

Burner

 

A. Remove the burner grates,

 

head

 

burner caps and burner heads.

 

B. Using a 7mm nut driver, remove the

 

top burner orifices. There are two

 

orifices per burner.

 

 

Burner

The main orifice is

Spark igniter

base

located low in the center

 

 

 

of the burner, while the

Simmer

Main

simmer orifice is located

orifice

 

higher beside the center

 

orifice

of the burner.

 

 

 

 

 

17

Image 17
Contents La section française commence à la Questions? Call 800.GE.CARESFor Your Safety Safety InformationBefore YOU Begin What to do if YOU Smell GASElectrical Requirements ContentsTools YOU will Need For Installation Installation PreparationModels Available Parts IncludedCooktop and ZVB36 Downdraft Vent Combination Installation Installation OptionsInstallation Above Cabinet Drawers Advance PlanningPRE-INSTALLATION Checklist Dimensions and Clearances Optional Combination Installations Power Supply LocationsGas supply Electrical supplyInstall the Cooktop Installation InstructionsInstall Pressure Regulator Connect ElectricalCheck igniters Assemble BURNERS, Check Ignition″ to Operation ChecklistBurners should be checked frequently Edges″ gap 23-5/16″total flat surface required at center Installation OptionsZTD910 28-1/2″ ZKD910 25-1/2″ 4 ″Dim. a Oven requires a separate, properly grounded Model ZET1 or ZET93836″ ″ min. countertop Height 28-5/8″max 23-1/2″minAdjust the Regulator Safety InformationTools YOU will Need for Conversion Change Burner OrificesAdjust Burner Flames Convert LP Gas Model ZGU385LSMSS to Natural Gas Operation Installation Instructions for LP to Natural Gas Conversion Avant DE Commencer Information de la sécuritéPour Votre Sécurité CI QUE Vous Devez Faire SI Voussentez LE GAZContenu Information de la sécurité Avertissement DébranchezBesoins D’ÉLECTRICITÉ Modèles Disponibles Préparation à l’installationPièces Comprises Matériaux Dont Vous Pourriez Avoir BesoinInstallation de la combinaison four simple ZET1 ou ZET938 Options D’INSTALLATIONInstallation au-dessus des tiroirs des armoires Planification AvancéeEmballage Liste DE Vérification DE PRÉ-INSTALLATIONCollé sur la face MousseDimensions ET Dégagements Installations de combinaison en option Emplacements DE L’ALIMENTATION DE GAZAlimentation de gaz 30,5 cm 12 poInstallez LE Régulateur DE Pression suite Instructions d’installationAvertissement ne réutilisez Avertissement n’utilisezVérifiez les allumeurs Avertissement allumerLes brûleurs doivent être régulièrement vérifiés Liste DE VérificationBrûleur de la Mm surface de cuisson 1/4 po Surface DE CUISSON-SPÉCIFICATIONS D’INSTALLATION Options d’installationDim. a 30 PO, Modèle ZET1 OU ZET938 Outils Nécessaires Pour LA Conversion Renseignements SUR LA SécuritéChangez LES Orifices DES Brûleurs EncolureQue sa position initiale Ajustez LA Flamme DU BrûleurPlus la valve qu’à sa position initiale Tester la stabilité de la flammeConvertir le modèle du gaz PL ZGU385LSMSS au gaz naturel Ajustez LA Flamme DU Brûleur GE Consumer & Industrial