GAS SUPPLY & INSTALLATION
D A N G E R
Installation, air adjustment and/or service work must be in accordance with all local codes and must be performed by a certified service technician qualified to work on gas appliances.
GAS REQUIREMENTS
The gas inlet is located at the back of the oven. Code requires the installation of a manual gas shutoff valve to be installed in the gas line ahead of the oven. This oven is also equipped with fixed burner orifices determined by the elevation specified as the initial installation location.
The oven is furnished with a regulator integral to the operation of the gas solenoid valve and may not require an additional external regulator. To ensure safe and proper operation, the gas pressure regulator installed in the oven is required for use with both natural gas and propane. If the connected pressure exceeds 14.0" W.C. (3.48 kPa), a
is required. A
Use an approved pipe sealant at all connections. Do not use Teflon® tape. Gas supply connections and pipe joint compound must be resistant to the action of propane gases. Pipes must be clean, free of obstructions and pipe joint compound.
INCORRECTCORRECT
GAS CONNECTION
In the U.S.A., installation must conform to local codes or, in the absence of local codes, with the current edition of the National Fuel Gas Code,
for Natural Gas Burning Appliances and
Equipment (latest edition) or
Installation for Propane Burning Appliances
and Equipment (latest edition).
The inlet supply line must be properly sized to accommodate all individual appliances simultaneously used on the same line but must never be smaller than 3/4" NPT.