INSTALLATION

The following ventilation cross-section and distances must be observed:

-There must be a ventilation space of at least 31 square inches (200 cm²) per appliance in the cabinet plinth and under the cabinet top panel.

-The depth of the ventilation duct at the rear of the cabinet must be at least 1- 1/2" (38 mm).

Alternatively:

1.For built-in appliances without ventilation grilles and only with an installation frame, ventilation must take place through the ventilation duct at the rear of the cabinet.

Built-in appliances with an installation frame:

Figure 19:

-Screw the complete installation frame (2) to the appliance.

(

1

1/2

 

 

38

 

 

 

mm)

At least 31 square inches (200cm2)

 

 

 

 

 

 

/4

 

)

 

3

 

m

0

 

 

2

 

 

m

 

 

 

7

 

 

 

2

 

 

 

5

 

 

 

 

(

 

 

 

 

 

1.

2

1

2.Built-in appliances with a wooden ventilation grille:

Figure 20: Cut out the wooden trim for use as a ventilation grille using the enclosed template.

-The required ventilation cross-section must be at least 31 square inches

(200 cm²) when a single appliance is installed, which corresponds to template “small” (If you install two appliances side-byside, the cross-section must be at least 62 square inches, (400 cm²), which corresponds to template “double-size;” for more information see “Side-by-Side

Installation”).

Remove the attachment bracket (2) from the installation frame and screw it to the appliance (1) from underneath. Place the wooden ventilation grille (5) on the appliance, align it in the center and secure it from the rear using the attachment bracket (2).

Figure 19

2

1/2"

5

(13 mm)

1

 

24"

 

(609.6 mm)

3-11/16"

 

(93,7 mm)

 

Figure 20

A delight in freshness

WF1051 / EWTNes 2956

15

Image 17
Contents Installation Instructions Please Read and Follow These Instructions To the Installer Table of Contents Installation Guidelines Planning Information Cabinet Opening DimensionsWF1051 Figure Side-By-Side WF1051 and RB1400 Figure 130 Planning Information Fig.A BGENes Reversing Door HingesUnscrew the lower hinge Finally mounting screw M4 Fig.D1-2 BGENes Door Opening Angle Figures 7Unpacking InstallationSpanner Built-in appliances with a wooden ventilation grille Fig.R BGENes Blocking for SafetyWater Connection Figure Do not install the shut-off valve behind the applianceIcemaker Solenoid valve is located at the rear of your unit Connection to the Water SupplyIcemaker Installation with SBS Ventilation Grille Set SIDE-BY-SIDE InstallationCa.210 Spanner Fig.Q BGENes Fig.S BGENes 31 Connect the appliancesSpanner At least 31 square inches 200cm2 per unit SIDE-BY-SIDE Installation