ICEMAKER

Water Connection - Figure 22

Please read the first three points of the safety instructions and warnings before connecting the appliance to the main water supply.

The water pressure must be between 21.8- 87.0 psi (1.5-6 bar).

Use a 1/4" OD copper line to connect the water supply to the solenoid valve. Allow extra length to the water supply line to provide slack for easy removal and to prevent the line from kinking.

This is not supplied with the appliance (Figure 22).

A shut-off valve, such as the saddle valve illustration here, must be installed between the hose line and the main water supply so the water supply can be stopped if necessary.

Do not install the shut-off valve behind the appliance.

Figure 22

If you have hard water, we recommend you install a water softener. Also, a filter must be installed if the water contains solids such as sand.

All equipment and devices used to supply the water to the appliance must comply with the current regulations for your geographical area.

A delight in freshness

WF1051 / EWTNes 2956

17

Image 19
Contents Installation Instructions Please Read and Follow These Instructions To the Installer Table of Contents Installation Guidelines Planning Information Cabinet Opening DimensionsWF1051 Figure Side-By-Side WF1051 and RB1400 Figure 130 Planning Information Fig.A BGENes Reversing Door HingesUnscrew the lower hinge Finally mounting screw M4 Fig.D1-2 BGENes Door Opening Angle Figures 7Unpacking InstallationSpanner Built-in appliances with a wooden ventilation grille Fig.R BGENes Blocking for SafetyIcemaker Do not install the shut-off valve behind the applianceWater Connection Figure Solenoid valve is located at the rear of your unit Connection to the Water SupplyIcemaker Installation with SBS Ventilation Grille Set SIDE-BY-SIDE InstallationCa.210 Spanner Fig.Q BGENes Fig.S BGENes 31 Connect the appliancesSpanner At least 31 square inches 200cm2 per unit SIDE-BY-SIDE Installation