Taylor TW-357 manual LABS-80K LABS-40K

Page 17

TW-357 REV E

Blood Bag Cassette

Blood Bag Storage in Cassette

LABS-20K

LABS-80K

 

 

LABS-40K

Fenwal 4R9951 Blood Bags – ask about other Bag types

 

 

PART NUMBER

CAPACITY

FRAMES

CASSETTES

LABS-80K

2100

300

2100

LABS-40K

1204

172

1204

LABS-20K

560

80

560

Figure 6.0 Fenwal 4R59951 Blood Bag Rack Arrangements

17

Image 17
Contents Labs TW-357 REV E Table of Contents InstallationExtreme Cold Cover Eyes and Exposed Skin Safety Precautions for Liquid NitrogenKeep Equipment Area Well Ventilated Liquid Nitrogen SystemElectrical Freight Damage PrecautionsDispose of Waste Liquid Nitrogen Safely Text Format Notation General InformationLabs Cryostorage Specifications Kryos Specifications Unpacking and Inspection InstallationLiquid Nitrogen Supply Connection Repackaging for ShipmentKryos Control Field Installation Power Supply ConnectionInitial Fill OperationInterface Panel Sensor AssemblyControl Components Battery Backup Lid SwitchRemote Alarm Solenoid ValveOperating Parameters Liquid Phase StorageThermocouple Positioning Adding an Inventory Control SystemInventory Control System Layouts Labs Cryostorage System Racks are not Square Orientation is ImportantLABS-80K LABS-40K Fenwal 4R59953 Blood Bag Rack Arrangements Fenwal 4R5462 9955 Blood Bag Rack Arrangements Control Operation PowerIntroduction Normal Fill CycleMenu System Main Display ScreenHigh Temperature 4.1 Valve Open Calibrate Temperature Temperature Thermocouple SelectTest Temperature System Help ScreensSensor Type Alarms and Error ConditionsLogging System AlarmsTest Alarms Dump Logs Error LogsSystem Logs Temperature LogsErase Logs SecurityControl By Temperature Lid Switch SetupTemperature Control Settings Control TemperatureTime and Date Set Serial Communications and RS-232 SettingsUser Access Logs Freeze-Guard Options Control RangeValve Monitoring Valve Open DurationSolenoid Valve Control On Battery Backup VersionDisplay Brightness About this ControlInterface Software Battery LifeDefrosting Your LAB-Series CryoStorage System MaintenanceStrainer Cleaning Instructions Cleaning Your Taylor-Wharton CryoStorage System Making Adjustments to the Labs Kryos Sensor Assembly Kryos Kryos V9.0 & Kryos V9.0B Level Readings Default Start Fill / Stop Fill Default Auto DefogOffset Value Units of measureOhms to 18 K ohms Removing/Installing the Solenoid ValvePin View Schematics Sensor Plug SchematicPlumbing Assembly Labs Plumbing AssemblySymptoms TroubleshootingController Will Not Turn on Indicates High Liquid LevelIndicates Open Sensor Temperature reading 10 to 20 degrees warmIndicates Low LN2 Supply QCF Quick Chill Feature Will Not Operate Lid Open AlarmFill Solenoid Cycles On and Off Fill Solenoid Makes Humming NoisePower Failure Alarm Defog Feature Will Not OperatePush Buttons Will Not Respond Liquid Level Readout is IncorrectFactory Settings Level Controller Electrical/Mechanical Parts80K/40K/20K Replacement PartsTaylor-Wharton Technical Services. Phone 800-898-2657 Fax Harsco Corporation