Taylor TW-357 manual Labs Plumbing Assembly

Page 39

LABS Plumbing Assembly

Freeze-Guard

Sensor

Male Branch

Tee

90 deg Elbow

TW-357 REV E

Solenoid Valve

90 deg Elbow

Male Branch

Tee

Reducer

Strainer

Relief Valve Tube

Female Connector

Relief Valve

Figure 10.0 Plumbing Assembly

39

Image 39
Contents Labs TW-357 REV E Table of Contents InstallationLiquid Nitrogen System Safety Precautions for Liquid NitrogenExtreme Cold Cover Eyes and Exposed Skin Keep Equipment Area Well VentilatedFreight Damage Precautions Dispose of Waste Liquid Nitrogen SafelyElectrical Text Format Notation General InformationLabs Cryostorage Specifications Kryos Specifications Repackaging for Shipment InstallationUnpacking and Inspection Liquid Nitrogen Supply ConnectionKryos Control Field Installation Power Supply ConnectionInitial Fill OperationSensor Assembly Control ComponentsInterface Panel Solenoid Valve Lid SwitchBattery Backup Remote AlarmOperating Parameters Liquid Phase StorageThermocouple Positioning Adding an Inventory Control SystemInventory Control System Layouts Labs Cryostorage System Racks are not Square Orientation is ImportantLABS-80K LABS-40K Fenwal 4R59953 Blood Bag Rack Arrangements Fenwal 4R5462 9955 Blood Bag Rack Arrangements Normal Fill Cycle PowerControl Operation IntroductionMenu System Main Display ScreenHigh Temperature 4.1 Valve Open Help Screens Temperature Thermocouple SelectCalibrate Temperature Test Temperature SystemSensor Type Alarms and Error ConditionsSystem Alarms Test AlarmsLogging Dump Logs Error LogsSecurity Temperature LogsSystem Logs Erase LogsControl Temperature Lid Switch SetupControl By Temperature Temperature Control SettingsSerial Communications and RS-232 Settings User Access LogsTime and Date Set Valve Open Duration Control RangeFreeze-Guard Options Valve MonitoringAbout this Control Control On Battery Backup VersionSolenoid Valve Display BrightnessInterface Software Battery LifeMaintenance Strainer Cleaning InstructionsDefrosting Your LAB-Series CryoStorage System Cleaning Your Taylor-Wharton CryoStorage System Making Adjustments to the Labs Kryos Sensor Assembly Units of measure Default Start Fill / Stop Fill Default Auto DefogKryos Kryos V9.0 & Kryos V9.0B Level Readings Offset ValueOhms to 18 K ohms Removing/Installing the Solenoid ValvePin View Schematics Sensor Plug SchematicPlumbing Assembly Labs Plumbing AssemblyIndicates High Liquid Level TroubleshootingSymptoms Controller Will Not Turn onTemperature reading 10 to 20 degrees warm Indicates Low LN2 SupplyIndicates Open Sensor Fill Solenoid Makes Humming Noise Lid Open AlarmQCF Quick Chill Feature Will Not Operate Fill Solenoid Cycles On and OffLiquid Level Readout is Incorrect Defog Feature Will Not OperatePower Failure Alarm Push Buttons Will Not RespondFactory Settings Level Controller Electrical/Mechanical Parts80K/40K/20K Replacement PartsTaylor-Wharton Technical Services. Phone 800-898-2657 Fax Harsco Corporation