TW-357 REV E

Blood Bag Cassette

Blood Bag Storage in Cassette

LABS-20K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LABS-80K

 

 

 

 

 

LABS-40K

Fenwal 4R5462 – 9955 Blood Bags – ask about other Bag types

 

 

 

 

 

PART NUMBER

 

 

CAPACITY

 

 

FRAMES

 

 

CASSETTES

 

 

 

LABS-80K

 

 

1050

 

 

210

 

 

1050

 

 

 

LABS-40K

590

 

118

 

590

 

 

 

LABS-20K

290

 

58

 

290

 

 

Figure 8.0 Fenwal 4R5462 – 9955 Blood Bag Rack Arrangements

19

Image 19
Contents Labs TW-357 REV E Table of Contents InstallationLiquid Nitrogen System Safety Precautions for Liquid NitrogenExtreme Cold Cover Eyes and Exposed Skin Keep Equipment Area Well VentilatedDispose of Waste Liquid Nitrogen Safely Freight Damage PrecautionsElectrical Text Format Notation General InformationLabs Cryostorage Specifications Kryos Specifications Repackaging for Shipment InstallationUnpacking and Inspection Liquid Nitrogen Supply ConnectionKryos Control Field Installation Power Supply ConnectionInitial Fill OperationControl Components Sensor AssemblyInterface Panel Solenoid Valve Lid SwitchBattery Backup Remote AlarmOperating Parameters Liquid Phase StorageThermocouple Positioning Adding an Inventory Control SystemInventory Control System Layouts Labs Cryostorage System Racks are not Square Orientation is ImportantLABS-80K LABS-40K Fenwal 4R59953 Blood Bag Rack Arrangements Fenwal 4R5462 9955 Blood Bag Rack Arrangements Normal Fill Cycle PowerControl Operation IntroductionMenu System Main Display ScreenHigh Temperature 4.1 Valve Open Help Screens Temperature Thermocouple SelectCalibrate Temperature Test Temperature SystemSensor Type Alarms and Error ConditionsTest Alarms System AlarmsLogging Dump Logs Error LogsSecurity Temperature LogsSystem Logs Erase LogsControl Temperature Lid Switch SetupControl By Temperature Temperature Control SettingsUser Access Logs Serial Communications and RS-232 SettingsTime and Date Set Valve Open Duration Control RangeFreeze-Guard Options Valve MonitoringAbout this Control Control On Battery Backup VersionSolenoid Valve Display BrightnessInterface Software Battery LifeStrainer Cleaning Instructions MaintenanceDefrosting Your LAB-Series CryoStorage System Cleaning Your Taylor-Wharton CryoStorage System Making Adjustments to the Labs Kryos Sensor Assembly Units of measure Default Start Fill / Stop Fill Default Auto DefogKryos Kryos V9.0 & Kryos V9.0B Level Readings Offset ValueOhms to 18 K ohms Removing/Installing the Solenoid ValvePin View Schematics Sensor Plug SchematicPlumbing Assembly Labs Plumbing AssemblyIndicates High Liquid Level TroubleshootingSymptoms Controller Will Not Turn onIndicates Low LN2 Supply Temperature reading 10 to 20 degrees warmIndicates Open Sensor Fill Solenoid Makes Humming Noise Lid Open AlarmQCF Quick Chill Feature Will Not Operate Fill Solenoid Cycles On and OffLiquid Level Readout is Incorrect Defog Feature Will Not OperatePower Failure Alarm Push Buttons Will Not RespondFactory Settings Level Controller Electrical/Mechanical Parts80K/40K/20K Replacement PartsTaylor-Wharton Technical Services. Phone 800-898-2657 Fax Harsco Corporation