REPLACEMENT PARTS

Refrigerator Parts (LABS)

80K/40K/20K

Lid Assembly……………………………………………………………LA80-9C85/LA40-9C85/LA20-9C85

Caster, ……………….. …………………………………………………………… 7300-8040

Decal, Warning……………………………………………………………………. R23K-9C42

Decal, Warning…………………………………………………………………

R10K-9C42

Inventory Rack 25 Vials [13 shelves tall for 2 in (51mm.) boxes] (ea.)……………

R10K-9C44

Inventory Rack 100 Vials [13 shelves tall for 2 in (51mm.) boxes] (ea.)

R23K-8C35

Level Controller Electrical/Mechanical Parts80K/40K/20K

Controller KRYOS ……...………………………………………………………… 5140-1159 (80K/40K)

Controller KRYOS (Battery Backup)…………………………………………… 5140-1158

Freeze Guard Sensor Assembly ……………………………………………………. 5140-1161

Sensor Assembly 7 Sensor ………………………………………………………. 5140-1163

8 Thermistor (option)……………………………………………………... 5140-1164

4 Thermistor (option)……………………………………………………… 5140-1162

Remote Alarm Plug………………………………………………………………… 5140-1160

Transformer 24VAC …………………………………………………………….… R08K-9C04(80K/40K)

Transformer 16.5VAC……………………………………………………………..

5140-1170

Battery, 12 Volt, 18Amp Hour………………………………………….

5140-1185

Battery Cable……………………………………………………………… 5140-1182

Thermocouple Assembly………………………………………………………….. R08K-9C51

Lid Switch…………………………………………………………………………

5140-1195

Plumbing Assy. 16.5 VAC……………..……………………………………………LA80-8C65 (80K)

LA40-8C65 (40K/20K)

Solenoid Valve 16.5 VAC (DC)..……………………………….………… 6999-9024

Plumbing Assy. 24 VAC……………..………………………………………...…....LA80-8C64 (80K)

LA40-8C64 (40K)

Solenoid Valve 24 VAC (AC)..…………………………………………… 6999-9021 (80K/40K)

Relief Valve 100 psig (6.9 bar/690kPa) ¼ in. NPT………………………………… 6913-9077

Strainer…………………………………………………………………………….. 7631-1080

45

Image 45
Contents Labs TW-357 REV E Table of Contents InstallationExtreme Cold Cover Eyes and Exposed Skin Safety Precautions for Liquid NitrogenKeep Equipment Area Well Ventilated Liquid Nitrogen SystemFreight Damage Precautions Dispose of Waste Liquid Nitrogen SafelyElectrical Text Format Notation General InformationLabs Cryostorage Specifications Kryos Specifications Unpacking and Inspection InstallationLiquid Nitrogen Supply Connection Repackaging for ShipmentKryos Control Field Installation Power Supply ConnectionInitial Fill OperationSensor Assembly Control ComponentsInterface Panel Battery Backup Lid SwitchRemote Alarm Solenoid ValveOperating Parameters Liquid Phase StorageThermocouple Positioning Adding an Inventory Control SystemInventory Control System Layouts Labs Cryostorage System Racks are not Square Orientation is ImportantLABS-80K LABS-40K Fenwal 4R59953 Blood Bag Rack Arrangements Fenwal 4R5462 9955 Blood Bag Rack Arrangements Control Operation PowerIntroduction Normal Fill CycleMenu System Main Display ScreenHigh Temperature 4.1 Valve Open Calibrate Temperature Temperature Thermocouple SelectTest Temperature System Help ScreensSensor Type Alarms and Error ConditionsSystem Alarms Test AlarmsLogging Dump Logs Error LogsSystem Logs Temperature LogsErase Logs SecurityControl By Temperature Lid Switch SetupTemperature Control Settings Control TemperatureSerial Communications and RS-232 Settings User Access LogsTime and Date Set Freeze-Guard Options Control RangeValve Monitoring Valve Open DurationSolenoid Valve Control On Battery Backup VersionDisplay Brightness About this ControlInterface Software Battery LifeMaintenance Strainer Cleaning InstructionsDefrosting Your LAB-Series CryoStorage System Cleaning Your Taylor-Wharton CryoStorage System Making Adjustments to the Labs Kryos Sensor Assembly Kryos Kryos V9.0 & Kryos V9.0B Level Readings Default Start Fill / Stop Fill Default Auto DefogOffset Value Units of measureOhms to 18 K ohms Removing/Installing the Solenoid ValvePin View Schematics Sensor Plug SchematicPlumbing Assembly Labs Plumbing AssemblySymptoms TroubleshootingController Will Not Turn on Indicates High Liquid LevelTemperature reading 10 to 20 degrees warm Indicates Low LN2 SupplyIndicates Open Sensor QCF Quick Chill Feature Will Not Operate Lid Open AlarmFill Solenoid Cycles On and Off Fill Solenoid Makes Humming NoisePower Failure Alarm Defog Feature Will Not OperatePush Buttons Will Not Respond Liquid Level Readout is IncorrectFactory Settings Level Controller Electrical/Mechanical Parts80K/40K/20K Replacement PartsTaylor-Wharton Technical Services. Phone 800-898-2657 Fax Harsco Corporation