Step 5
Step 6
Step 7
Step 8
Pedestal Mount
Bearing Pad
Adjustment
Step 1
Step 2
Step 3
Step 4
Step 5
Turn the ELEVATION DOWN/UP switch to either position and while the antenna is rotat- ing, carefully use a
Repeat the preceding step (5) with the ELEVATION DOWN/UP switch in the alternate operating position.
Repeat steps 3 through 6 with the Az/El speed in the SLOW position.
If all voltage and current readings are within tolerance, turn the primary power discon- nect switch OFF. Then close and lock the outer local motor controller door. Disconnect the hand held controller to return antenna control to studio.
The bearing pad (within the pedestal mount) adjustment rods/bolts require yearly adjust- ment and verification of torque value. With the antenna at zenith (90 degrees), follow the procedures presented below:
Loosen jam nuts on all rods/bolts.
Torque the upper adjustment rod evenly to
Torque the upper adjustment bolt evenly to
Repeat steps 2 and 3 verifying all adjustment rods/bolts are evenly torqued within the limits specified.
Tighten the jam nuts.
78 | Preventive Maintenance |