WARNING: CO2 displaces oxygen. Strict attention must be observed in the prevention of CO2 (carbon dioxide) gas leaks in the entire CO2 and soft drink system. If a CO2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and suffocation.
1.Unscrew protector cap (with chain attached) from CO2 cylinder valve. Open CO2 cylinder valve slightly counterclockwise to blow any dirt or dust from outlet fitting before installing primary CO2 regulator, then close valve.
2.Remove shipping plug from primary CO2 regulator assembly coupling nut and make sure gasket is in place inside nut. Install regulator assembly on CO2 cylinder so gages can be easily read, then tighten coupling nut. DO NOT OPEN CO2 CYLINDER VALVE AT THIS TIME.
CONNECTING SOFT DRINK TANKS CO2 LINES TO PRIMARY CO2 REGULATOR ASSEMBLY
(see Figure 2)
1.Connect soft drink tanks CO2 lines to primary CO2 regulator manifold assembly as shown in Figure 2.
2.Install gas quick disconnects on ends of soft drink tanks CO2 lines. DO NOT CONNECT CO2 LINES TO TANKS AT THIS TIME.
PREPARING UNIT SYRUP INLET LINES FOR CONNECTION TO SOFT DRINK TANKS
(see Figure 2)
1.Route Unit syrup inlet lines, labeled No. 1 and No. 2, out through hole provided in Unit base to soft drink tanks location.
2.Install liquid disconnects on ends of Unit syrup inlet lines. DO NOT CONNECT SYRUP LINES TO TANKS AT THIS TIME.
CONNECTING PLAIN WATER INLET SUPPLY LINE TO UNIT
(see Figure 2)
NOTE: IMI Cornelius Inc. recommends that a water shutoff valve and water filter be installed in plain water inlet supply line (see Figure 2). A Cornelius Water Filter (P/N 313860000) and Quick Disconnect Set (P/N 313867000) are recommended.
1.Before connecting plain water inlet supply line to Unit, open shutoff valve in water supply line for a period of time to flush out any metal shavings.
2.Route water inlet line out through hole in bottom of Unit base.
NOTE: Carbonator plain water inlet adjustable water pressure regulator (see Figure 12) is factory adjusted to
3.Connect Unit water inlet line to plain water inlet supply line
326142000 | 10 |