Cornelius 326142000 ALL Fault Messages not, ‘‘CO2 OUT’’ Fault Message, Goes on During, Operation

Page 70

Trouble

 

Probable Cause

 

Remedy

ALL FAULT MESSAGES NOT

D.

Master circuit board not

D.

Replace master circuit board.

OPERATING. (cont’d)

 

operating.

 

 

 

E.

Fault message display module

E.

Replace fault message display

 

 

not operating properly.

 

module.

 

 

 

 

 

‘‘CO2 OUT’’ FAULT MESSAGE

A.

CO2 supply turned off or

A.

Open CO2 cylinder shutoff valve

GOES ON DURING

 

exhausted.

 

or replenish CO2 supply as

OPERATION.

 

 

 

instructed.

 

B.

Primary CO2 regulator set too

B.

Adjust primary CO2 regulator as

 

 

low.

 

instructed.

 

C.

Inoperable CO2 pressure

C.

Replace CO2 pressure switch.

 

 

switch.

 

 

 

 

 

 

 

‘‘H2O OUT’’ FAULT MESSAGE

A.

Water supply turned off or

A.

Turn on water supply or check

GOES ON DURING

 

water pressure inadequate.

 

water supply line pressure.

OPERATION.

 

 

 

 

 

B.

Plugged water filter or water

B.

Change water filter or clean water

 

 

pump strainer screen.

 

pump strainer screen as

 

 

 

 

instructed.

 

C.

Inoperative water pressure

C.

Replace water pressure switch.

 

 

switch.

 

 

 

 

 

 

 

‘‘SYRUP 1’’ OR ‘‘SYRUP 2’’

A.

Soft drink tank empty.

A.

Replenish syrup supply as

FAULT MESSAGE GOES ON

 

 

 

instructed.

DURING OPERATION.

 

 

 

 

 

 

 

 

 

‘‘ERROR 1’’ OR ‘‘ERROR2’’

A.

Error within Unit has

A.

Locate and correct error, then

FAULT MESSAGE GOES ON

 

developed interrupting normal

 

press ‘‘ERROR RESET’’ switch to

DURING OPERATION.

 

operation.

 

restore normal operation.

 

 

 

 

 

FREEZE CYLINDER

A.

Loose or broken electrical

A.

Repair electrical wires.

AUTOMATIC DEFROST

 

wires.

 

 

CYCLE DOES NOT

 

 

 

 

OPERATE.

 

 

 

 

 

B.

Inoperable automatic defrost

B.

Replace master circuit board.

 

 

timer.

 

 

 

 

 

 

 

UNIT DOES NOT GO OFF

A.

Automatic defrost timer stuck

A.

Replace master circuit board.

AUTOMATIC DEFROST

 

in automatic defrost cycle.

 

 

CYCLE.

 

 

 

 

 

 

 

 

 

MANUAL DEFROST CYCLE

A.

Flat cable not properly

A.

Properly connect flat cable to

DOES NOT OPERATE WHEN

 

connected to control switch

 

control switch module or master

‘‘DEFROST’’ SWITCH IS

 

module or master circuit

 

circuit board.

PRESSED.

 

board.

 

 

 

B.

Flat cable connected between

B.

Check cable for pinched or

 

 

control switch module and

 

broken wire condition and repair

 

 

master circuit board pinched

 

or replace as necessary.

 

 

and shorted out or broken wire

 

 

 

 

in cable.

 

 

 

C.

Inoperable ‘‘DEFROST’’ switch

C. Replace control panel switch

 

 

on control panel switch

 

module.

 

 

module.

 

 

 

D. Loose or broken wire.

D.

Repair wire.

 

E.

Master circuit board not

E.

Replace master circuit board.

 

 

operating properly.

 

 

 

 

 

 

 

63

326142000

 

Image 70
Contents FCB SOLID-STATE Post MIX Dispenser This Document Contains Important InformationTable of Contents Table of Contents cont’d Dispensing Valves Caged O-RINGS and Beaters Drive Programming Main Menu Selection Onto Message DisplayServicing Carbonator Water Pump Double Liquid Check Troubleshooting Control Panel Switches and Fault‘‘VIS READ’’ Actual Viscosity Readout of Product Replacing Freeze Cylinder Beater Drive Shaft BearingFreeze Cylinder Automatic Defrost Cycle does not ‘‘ERROR 1’’ or ‘‘ERROR2’’ Fault Message Goes on DuringGeneric Flavor Tabs Service Tools List of FiguresList of Tables List of Figures CONT’DTotals Displayed Cycles and Hours Totals Menu General Description Unit DescriptionTheory of Operation Defrost SystemsManual Defrost System ‘‘SLEEP’’ Sleep Time‘‘WAKE UP’’ Wake UP Time Automatic Defrost SystemFlow Diagram Unpacking and Inspection Identification of LOOSE-SHIPPED PartsElectrical Power Requirements Installing Beaters Item 11 and Scraper Blades ItemDomestic Unit Freeze Cylinder Cutaway View Selecting Location Export UnitInstalling Drip Tray Drain KIT Item Installing UnitInstalling Drip Tray SUPPORTS, Drip TRAY, and CUP Rest Installing Primary CO2 Regulator Assembly on CO2 CylinderConnecting Plain Water Inlet Supply Line to Unit Preparation for Operation Connecting Electrical Power Circuit to Unit50 or 60 HZ Operation and Beater Motor Select Turning on CO2 Supply to Unit Turning on Electrical Power to UnitConnecting Soft Drink Tanks to Unit Syrup Systems Turning on Plain Water Supply to UnitAdjusting Brix WATER-TO-SYRUP ‘‘RATIO’’ of Dispensed Product Programming ‘‘DEFROST’’ Automatic Settings Into Unit Adjusting Beater Motor Current Either SideSetting ‘‘CLOCK’’ Time of DAY Filling Freeze Cylinders with ProductDisplayed Error Conditions Displayed Error Conditions‘‘VOLTAGE’’ Displayed Voltage Readout This page Left Blank Intentionally Control Panel Switches and Displayed Messages Control Panel Switches‘‘SECURITY SWITCH.’’ Control Panel Display MessagesFreeze Cylinders Manual or Automatic Defrost Systems Product Shutoff Valves Faceplate Relief ValvesProduct Sample Valves Primary CO2 RegulatorOperating Characteristics DrawingProduct Flavor Change Operating UnitReplenishing Syrup Supply Checking CO2 SupplyCleaning Condenser Coil Lubrication Cleaning and SanitizingAdjustments Programming Main Menu Selections Onto Message Display Displayed Error Conditions Cleaning CO2 GAS Check ValvesThis page Left Blank Intentionally Preparing Unit for SHIPPING, STORING, or Relocating Periodic InspectionCondenser Coil Access Panel Lower Front Access PanelCarbonator Water Pump Motor 326142000 Operating Controls Unit Internal Components Cleaning Condenser Coil SELF-CLOSING Dispensing ValveAdjusting Plain Water Pressure Regulator Adjusting Carbonated Water Flow RateAdjusting CO2 Regulators Product Carbonation Adjustment ADJUSTMENTS, and Programming Main Menu Selections Into Unit Menu Commands Setting Clock Time of DAYHidden Security Switch Message Display Programming Main Menu Selection Onto Message DisplayProgramming ‘‘DEFROST’’ Automatic Settings Into Unit Master and Relay Circuit Boards Beater Motor Select DIP Switch Message Switch FunctionDIP Switch Functions Motor Selected Point of Sale Display MessagesAdjusting VIS SET Product Viscosity of Dispensed Product ‘‘VOLTAGE’’ Displayed Voltage Readout Totals Menu Commands Description Syrup Minutes SideDisplayed Error Conditions BrixDaily Cleaning of Unit Sanitizing Syrup Systems326142000 326142000 Yearly or After Water System Disruption Servicing Carbonator Water Pump Water Strainer ScreenServicing Carbonator Water Pump Double Liquid Check Valve Replenishing CO2 Supply Syrup Flavor Change Water Strainer Screen and Double Liquid Check Valve Replacing Freeze Cylinder Beater Drive Shaft Bearing Cleaning CO2 GAS Check ValvesShutting Unit Down Installing Beater Drive Shaft Bearing ASS’Y Beater Drive Motor and Shaft Seal ASS’Y ReplacementRestoring Unit Operation Replacing Beater Drive Shaft Seal ASS’YReplacing Freeze Cylinder Beater Motor Drive motorAdjusting Carbonator Tank Liquid Level Carbonator Liquid Level Control Switch Adjustment Refrigeration Flow Diagram Wiring Dirgram Troubleshooting Control Panel Switches and Fault Messages Cannot be Deactivated Control Panel SwitchesPoorly Illuminated Display ONE or More Fault Partial Message or Dull‘‘H2O OUT’’ Fault Message ALL Fault Messages not‘‘CO2 OUT’’ Fault Message Fault Message Goes onTroubleshooting Product Blender Tanks and Carbonators Troubleshooting Dispensed Product Instructed Accessories and ToolsService Tools Generic Flavor TabsFCB SOLID-STATE POST-MIX Dispenser FCB POST-MIX Dispenser FCB POST-MIX Dispenser CONT’D FCB Flow Diagram FCB POST-MIX Dispenser By 1/2-In. Long Faceplate Assembly Dispensing Valve Assembly CO2 Regulator Assembly Carbonator Assembly Name Warranty This page Left Blank Intentionally One Cornelius Place Anoka, Minnesota 612 800