DCS CP-366, CP-484GG, CP-485GD, CP-486GL, CP-364GL, CP-486GD, CP-364GD Cooktop USE, Burners, Simmering

Page 10

COOKTOP USE

BURNERS

Your new professional cooktop is equipped with burners typical of those used in restaurants. These burners are designed for maximum cleanability and controllability. The large cap spreads the simmer heat out to avoid too much heat being concentrated on the center of the pan. The simmer flame is always “on” when the burner is in use. The burner should never be operated if the cap is not in place. All the cooktop burners have electronic spark ignition to eliminate continuously burning pilots; when the burner is on and the flame is blown out, it will relight.

CAP

BRASS

PORT

RING

SIMMER FLAME

Fig. 01

SIMMERING

Your new professional cooktop has exceptionally low simmering capabilities. The large cap serves as a heat diffuser to spread out the heat to avoid having a center hotspot. Keep in mind that because of the high heat capacity of the retention flame, and the mass of the cast iron burner grates (they retain heat longer than lighter, conventional grates) some foods may continue to cook by retained heat after the burner has been turned off. Should a strong draft or boil over extinguish the simmer flame it will relight automatically as the main burner would.

Burner

Max.

 

Simmer/Low

Location

Btu/hr

Btu/hr

 

Nat

 

LP

Nat

LP

1

17,500

 

15,000

500-1,200

500-1,200

2

12,500

 

12,500

500-1,200

500-1,200

3

12,500

 

12,500

500-1,200

500-1,200

 

 

 

 

 

 

4

17,500

 

15,000

500-1,200

500-1,200

 

 

 

 

 

 

5

17,500

 

15,000

500-1,200

500-1,200

6

17,500

 

15,000

500-1,200

500-1,200

2

4

6

1

3

5

2

1

4

3

2

1

4

5

3

CP-366 COOKTOP SECTION SHOWN

CP-364 COOKTOP SECTION SHOWN

CP-485 COOKTOP SECTION SHOWN

2

1

4

3

2

1

4

3

6

5

CP-484 COOKTOP SECTION SHOWN

CP-486 COOKTOP SECTION SHOWN

8

Image 10
Contents Professional GAS Cooktop Page Message to OUR Customers If You Smell GasTable of Contents Safety Practices and Precautions Safety Practice and Precautions Recommendations on HOOK-UP to GAS Supply Model Identification Before Using Your Appliance Burners Cooktop USESimmering Flame Height Burner Efficiency and Flame CharacteristicsElectronic Igniters Cooktop BurnersCookware Burner GratesControl Knobs Grill USE Griddle USE Grilling HintsGriddle Cooking Chart Before Using the Griddle for the First Time or to RE-SEASONUSE of the Griddle Brand Name Cleaners Care and MaintenanceWhen Cleaning the Cooktop CooktopSump Area around Burners and Igniters For Hard to Clean SOIL, USE this EmthodIgniters Drip Trays and Drain TubesGriddle To remove drip tray if neededBackguard if installed Power FailureParts Identification Item DescriptionTroubleshooting Ranges & CooktopsBefore YOU Call for Service HOW to Obtain ServiceIf the Cooktop Burners do not Light HOW Long does this Limited Warranty LAST? WarrantyLimited Warranty This Warranty does not CoverCommercial USE HOW to GET ServiceNo Other Warranties LA Table DE Cuisson À GAZ Professionnelle Notre Clientèle Veuillez Conserver CE Manuel À Titre DE RéférenceTable DES Matières Mesures DE Sécurité ET DE Précaution Mesures DE Sécurité ET DE Précaution Recommandations Concernant LE Branchement DU GAZ RemarqueIdentification DU Modèle Avant Dutiliser Votre Appareil Table DE CuissonBrûleurs Utilisation DE LA Table DE CuissonCuisson À Petit FEU Hauteur DE LA Flamme Allumeurs ÉlectroniquesEfficacité DES Brûleurs ET Caractéristiques DE LA Flamme Brûleurs DE Table DE CuissonUstensiles Grilles DES BrûleursBoutons DE Réglage Utilisation DU Gril Utilisation DE LA Plaque Chauffante Utilisation DE LA Plaque ChauffanteTableau DE Cuisson DE LA Plaque Chauffante Durant LE Nettoyage DE LA Cuisinière OU Table DE Cuisson Entretien ET MaintenanceMarque DE Nettoyants Allumeurs Zone DE Collecte Autour DES Brûleurs ET DES AllumeursRAMASSE-GOUTTES ET Tubes Dégouttement Plaque ChauffanteDosseret si installé Panne DalimentationIdentification DES Pièces DescriptionDépannage Cuisinières ET Tables DE CuissonAvant Dappeler LE Service Technique Pour Lobtention DE ServiceSI LES Brûleurs DE LA Table DE Cuisson NE Sallument PAS Quelle EST LA Durée DE Cette Garantie LIMITÉE? GarantieFisher & Paykel Sengage À NE Sont PAS Couverts PAR LA GarantieUtilisation Commerciale Pour Obtenir DES RéparationsAucune Autre Garantie

CP-364GD, CP-486GD, CP-364GL, CP-366, CP-486GL specifications

DCS (Dual Control Systems) has made significant strides in the world of dynamic control solutions, with their new line of products, namely the CP-484GG, CP-485GD, CP-486GL, CP-366, and CP-364GL. Each model is designed with a unique set of features and advancements that cater to various applications within industrial and commercial settings.

The CP-484GG is particularly noteworthy for its enhanced graphical user interface, offering operators intuitive touch controls and customizable layouts. This model boasts a high-resolution display, making it easier for users to monitor system performance in real time. The CP-484GG is built on a robust platform that supports multi-protocol communication, ensuring seamless integration with existing control systems.

Next in line, the CP-485GD emphasizes the importance of data processing speed. With an embedded intelligent processing unit, the CP-485GD can handle complex calculations and manage multiple control loops simultaneously without sacrificing performance. One of its standout features is the advanced predictive maintenance technology that anticipates potential failures before they occur, reducing downtime and maintenance costs significantly.

The CP-486GL takes innovation a step further with its focus on energy efficiency. Designed to minimize power consumption while maximizing output, this model incorporates energy harvesting technology that captures and reuses energy within the system. The CP-486GL is compatible with renewable energy sources, making it a sustainable choice for modern facilities looking to decrease their carbon footprint.

The CP-366, on the other hand, is engineered for versatility. This compact control panel offers a wide range of I/O options, allowing users to configure it for various applications. The CP-366 comes equipped with high-speed data logging capabilities, enabling detailed analysis of operational data over time, which is crucial for process optimization.

Lastly, the CP-364GL stands out for its durability and rugged design. Built to withstand harsh environmental conditions, the CP-364GL is ideal for use in outdoor settings or industrial areas where exposure to the elements is a concern. Its corrosion-resistant materials and IP67 rating make it an excellent choice for demanding applications.

In summary, DCS's CP-484GG, CP-485GD, CP-486GL, CP-366, and CP-364GL reflect the company's commitment to innovation, efficiency, and reliability in control solutions. Each model comes equipped with cutting-edge technologies that enhance performance and adaptability for a range of industries, paving the way for smarter, safer, and more efficient operations.