Agilent Technologies 6610XA appendix R305 R306 R307 R308 R309 R310 R311 R312 R313 R314 R315

Page 74

Table 5-1. Agilent 6610xA Power Modules Parts List - Electrical (continued)

Reference

Designators

R305

R306

R307

R308

R309

R310

R311

R312

R313

R314

R315

Model

66101A

66102A

66103A

66104A

66105A

66106A

66101A

66102A

66103A

66104A

66105A

66106A

All Models

66101A-66104A

66105A

66106A

66101A-66104A

66105A

66106A

66101A

66102A

66103A

66104A

66105A

66106A

66101A

66102A

66103A

66104A

66105A

66106A

All Models

66101A

66102A

66103A

66104A, 66105A

66106A

66101A

66102A

66103A

66104A

66105A

66106A

66101A

66102A

66103A

66104A, 66105A

66106A

Part Number

0757-0441

0757-0449

0757-0123

0698-3572

0757-0467

0757-0472

0757-0441

0757-0449

0757-0123

0698-3572

0757-0467

0698-6358

0698-3279

0757-0472

0757-0270

0757-0472

Not Used

0811-1732

Not Used

0757-0441

0757-0446

0757-0444

0757-0946

0698-4444

0698-3498

0757-0458

0757-0462

0757-0458

0757-0349

0698-4486

0757-0449

0699-0070

0698-0085

0698-0084

0757-0279

0757-0427

0757-0279

0757-0442

0698-3162

0757-0458

0757-0449

0757-0461

0757-0469

0698-4435

0757-0439

0698-3153

0698-4435

0757-0440

Description

RES 8.25K 1%

RES 20K 1% .125W

RES 34.8K 1%

RES 60.4K 1%

RES 121K 1%

RES 200K 1%

RES 8.25K 1%

RES 20K 1% .125W

RES 34.8K 1%

RES 60.4K 1%

RES 121K 1%

RES 100K .1%

RES 4.99K 1%

RES 200K 1%

RES 249K 1%

RES 200K 1%

RES 1 3W 5%

RES 8.25K 1%

RES 15K 1% .125W

RES 12.1K 1%

RES 8.2K 2%

RES 4.87K 1%

RES 8.66K 1%

RES 51.1K 1%

RES 75K 1% .125W

RES 51.1K 1%

RES 22.6K 1%

RES 24.9K 1%

RES 20K 1% .125W

RES 3.16M 1%

RES 2.61K 1%

RES 2.15K 1%

RES 3.16K 1%

RES 1.5K 1%

RES 3.16K 1%

RES l0K 1% .125W

RES 46.4K 1%

RES 51.1K 1%

RES 20K 1% .125W

RES 68.1K 1%

RES 150K 1%

RES 2.49K 1%

RES 6.81K 1%

RES 3.83K 1%

RES 2.49K 1%

RES 7.5K 1%

74 Replacement Parts

Image 74
Contents Service Guide Agilent Part No Microfiche Part No Update JuneCertification Safety Summary Printing History Table of Contents Replacement Parts Diagrams About This Manual OverviewFirmware Revisions and Updates ManualRelated Documents Manual Part Number DescriptionElectrostatic Discharge Safety ConsiderationsService Tools and Equipment Recommended Model Service Test Equipment Equipment RequiredCritical Specifications Use1Verification and Performance Tests Operation Verification TestsPerformance Tests Programming Setup for Most TestsMeasurement Techniques Current-Monitoring ResistorCurrent Overvoltage CV SetupConstant Voltage CV Tests Voltage Programming/Readback AccuracyCV Noise Pard Transient Recovery TimeCV Source Effect Current Programming/Readback Accuracy CC SetupConstant Current CC Tests CC Load and Line RegulationCC Load Effect CC Source EffectCC Noise Pard Test Description SpecificationPerformance Test Record for Model Agilent 66101A 8V, 16A Measurement UncertaintyPerformance Test Record for Model Agilent 66102A 20V, 7.5A Performance Test Record for Model Agilent 66103A 35V, 4.5A Actual Verification and Performance TestsPerformance Test Record for Model Agilent 66104A 60V, 2.5A 1μV 7mV 230μV 0mV 5mV 15mV 15μA 157μA 4μA Performance Test Record for Model Agilent 66106A 200V, 0.75A Page Troubleshooting Troubleshooting SequenceAccessing the Flowcharts If You Experienced Other Problems With the Module Troubleshooting No OutputOverall Troubleshooting Sheet 1 Overall Troubleshooting Sheet 2 Overall Troubleshooting Sheet 3 Troubleshooting Microprocessor Circuits Sheet 1 Troubleshooting Microprocessor Circuits Sheet 2 Troubleshooting Error Messages Troubleshooting Overvoltage at Turn-On Sheet 1 Troubleshooting Overvoltage at Turn-On Sheet 2 Troubleshooting No Output Sheet 1 Troubleshooting No Output Sheet 2 Troubleshooting No Output Sheet 3 Troubleshooting No Output Sheet 4 Troubleshooting No Output Sheet 5 Troubleshooting High Output Troubleshooting Will Not Overvoltage Troubleshooting CV Accuracy Troubleshooting CC Accuracy 10. Troubleshooting Downprogrammer 11. Troubleshooting DAC Circuit 12. Troubleshooting Readback Circuits Sheet 1 12. Troubleshooting Readback Circuits Sheet 2 Test Point Test Points Description Test PointsBuilt-In Test Functions S3 Setting S3 Test Settings Test Description13. S3 Switch Setting Waveforms Troubleshooting Eeprom Troubleshooting and Initialization Initialization14. Eeprom Initialization Program Sheet 1 Troubleshooting 14. Eeprom Initialization Program Sheet 2 Troubleshooting 14. Eeprom Initialization Program Sheet 3 Troubleshooting 14. Eeprom Initialization Program Sheet 4 Troubleshooting Removing the Cover Disassembly ProceduresRemoving the Module and Module Connector Removing the FanRemoving the Bias Board Removing the Front Panel AssemblyRemoving the Power Board Removing the Front Panel BoardInstalling the Power Board Installing the Bias BoardInstalling the Cover Installing the Front Panel Board and Front Panel AssemblyInstalling the Fan Page CV/CC DACs AC Input and Bias SuppliesMicroprocessor Circuits Theory Of OperationBlock Diagram Thoery Of Operation Or Gates CV AmplifierCC Amplifier Readback Multiplexer Pulse-Width Modulator, FETS, and Isolation TransformerDownprogrammer Circuit OV Circuit Page Replacement Parts Replacement PartsModel Model Model DIODE-PWR Rect CHOKE-OUTPUT BEAD-FERRITE CONNECTOR, Hood ASSY-FET, HS Shunt .005 Ohms Shunt .01 Ohms Shunt .035 Ohms R305 R306 R307 R308 R309 R310 R311 R312 R313 R314 R315 Model RES-ZERO Ohms RES 9.31K 1% Replacement Parts All Models 66101A-66103A 66104A-66106A Agilent 6610xA Power Modules Parts List Mechanical Model Output Connector Assembly Parts List Reference Designators Page Diagrams Schematic SheetsComponent Location Diagrams Schematic Notes Page Page L305 Page Page Module Front Panel Page Page Page OUT Main Board Component Coordinates Page Number Changes Agilent Prefix Serial Number Make Model ChangesAgilent Prefix Serial Number Make BackdatingBackdating Index IndexSchematic Troubleshooting

6610XA specifications

Agilent Technologies has long been recognized for its innovative contributions to the fields of measurement and testing, and the Agilent 6610XA series of power supplies is no exception. Tailored for demanding applications in electronics and advanced research, the 6610XA series exemplifies cutting-edge technology blended with user-friendly features.

One of the main characteristics of the Agilent 6610XA is its ability to provide a stable, accurate, and reliable power supply across a range of applications. With output voltages that can reach as high as 60V and currents up to 10A, the device is versatile enough to cater to a variety of testing requirements. This power supply is ideal for applications including semiconductor testing, device characterization, and more, where precision and consistency are paramount.

Among the standout features of the Agilent 6610XA is its advanced graphical user interface (GUI), which enhances the overall user experience. The intuitive design allows engineers and technicians to monitor and control voltage and current settings easily, making the process of configuring the device both fast and efficient. Additionally, the device has built-in measurement capabilities that can display real-time voltage and current readings, significantly aiding in troubleshooting and performance evaluation.

Furthermore, the 6610XA incorporates a range of communication interfaces including USB, LAN, and GPIB, making it highly adaptable for integration into various automated test setups. This versatility signifies that the power supply can be seamlessly incorporated into existing laboratory environments, promoting productivity and efficiency.

The series also incorporates intelligent protection mechanisms to ensure both user safety and equipment longevity. Features such as overvoltage protection (OVP) and overcurrent protection (OCP) are designed to prevent accidental overloads, safeguarding both the device under test and the power supply itself.

Another key aspect is the series' capability to perform complex programming tasks with ease. With programming capabilities that enable users to set intricate voltage and current profiles, the device supports advanced applications, including load transient testing and sweep testing. This flexibility makes the Agilent 6610XA a valuable asset for any research and development environment looking to enhance testing efficiency and accuracy.

In conclusion, the Agilent 6610XA series power supply stands out for its combination of precision, user-friendliness, advanced communication capabilities, and safety features. These attributes make it a critical tool for engineers and researchers engaged in the rigorous demands of modern electronics testing and evaluation. With its continued commitment to innovation, Agilent Technologies reinforces its position as a leader in providing high-quality solutions for the measurement and testing industry.