Test Points
The following test points are referenced in the troubleshooting flowcharts. Refer to the component locations diagram in Chapter 6 for the actual location of the test points on the pc board.
Test Point
TP 0
TP 1
TP 2
TP 3
TP 4
TP 5
TP 6
TP 7
TP 8
TP 9
TP 10
TP 11
TP 12
TP 13
TP 14
TP 15
TP 16
TP 17
TP 18
TP 19
TP 20
TP 21
TP 22
Table 3-1. Test Points
Description
Output circuit common (located on inboard side of R303) +5V (4.8 to 5.2 volts)
+12V (11.4 to 12.6 volts)
+7V (6.7 to 7.3 volts)
+2.5V (2.4 to 2.6 volts)
+15V (14.25 to 15.75 volts, referenced to
+5V (4.75 to 5.25 volts, referenced to frame common)
+24V (24.3 to 27.3 volts, referenced to frame common)
+28V (unregulated, referenced to frame common)
Frame common \F /
PCLR* (goes low for 175ms at
+output
0
0
0 to 2V (A/D INPUT)
0 to 2V (VMON)
0 to 2V (IMON)
0 to 4V (OVREF)
1 Test Equipment must be isolated from ground.
Built-In Test Functions
To aid in troubleshooting, the module configuration switch (S3) can be set to run various test routines as described in the Overall Troubleshooting flowchart. To start the test, set all switches to 0 (down) and turn on ac power. Then set the switch to perform the selected test as shown in the following table.