Agilent Technologies 6610XA appendix All Models 66101A-66103A 66104A-66106A

Page 79

Table 5-1. Agilent 6610xA Power Modules Parts List - Electrical (continued)

Reference

Designators

U203

U204

U205

U206

U301

U302

U303

U304

U305

U306

U307

VR201

VR302 VR304, VR305 Y1

C401

C402

C404

C405

C406

C408, C410

C411

D401, D402

D402

F401

J401

J402

Q402

Q404

R403

R404

R405

R406

S402

T401

U401, U402

C501, C502 C503, C504 CR501-CR503 CR504-CR506 D501-D508 D509

J501

Model

All Models

All Models

All Models

All Models

66101A-66103A

66104A-66106A

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

Part Number

1826-2075

1990-1502

1858-0069

1826-0175

1826-0346

1826-0962

1826-1896

1826-1370

1826-1895

1826-1553

1990-1502

1826-0346

1902-0968

1902-0951

1902-0018

0410-2109

5060-3455

0180-3587

0180-4273

0160-5422

0180-3587

0180-4389

0180-4129

0160-4835

1901-0731

1901-0731

2110-0820

1252-0056

1251-8676

1826-0527

5060-2942

0699-0486

0699-1069

0698-3447

0757-0437

3101-2966

9100-4932

1906-0006

5060-3454

0160-5422

0160-4833

1990-1554

1990-1553

1990-1492

1902-3110

1252-3844

Description

IC UC3825N

OPTO ISOLATOR TRANSISTOR ARRAY 18P-DIP IC 319

IC OP-AMP

IC OP-AMP

IC-LINEAR IC 365 PRECISION OP-AMP IC-LINEAR

OPTO ISOLATOR IC OP-AMP DIODE-ZENER 27V 5% DIODE-ZENER DIODE-ZENER lN941 11.7V CRYSTAL 12.000 MHZ

ASSEMBLY-BIAS BOARD CAP 1000uF 50V

CAP 1000uF CAP .047uF 20% CAP 1000uF 50V CAP 6800uF 25V CAP luF 35V CAP .luF 10% 50V

DIODE-PWR RECT

DIODE-PWR RECT

FUSE .5A 250V, HOLDER (2110-0714)

CONNECTOR, TO POWER BOARD CONNECTOR, TO POWER BOARD IC LM337T

ASSY-HS, TO-220 RES 2K .1% .lW F RES 229 .1% RES 422 1% .125W RES 4.75K 1% SWITCH DPDT TRANSFORMER-BIAS DIODE BRIDGE 400V

ASSEMBLY-FRONT PANEL BOARD CAP .047uF 20%

CAP .022uF 10%

LED GREEN LED YELLOW DISPLAY, LED DIODE-ZENER 5.9V 2% CONNECTOR, TO POWER BOARD

Replacement Parts 79

Image 79
Contents Agilent Part No Microfiche Part No Update June Service GuideCertification Safety Summary Printing History Table of Contents Replacement Parts Diagrams Overview About This ManualManual Part Number Description Revisions and Updates ManualRelated Documents FirmwareService Tools and Equipment Safety ConsiderationsElectrostatic Discharge Use1 Service Test Equipment Equipment RequiredCritical Specifications Recommended ModelPerformance Tests Operation Verification TestsVerification and Performance Tests Current-Monitoring Resistor Setup for Most TestsMeasurement Techniques ProgrammingVoltage Programming/Readback Accuracy CV SetupConstant Voltage CV Tests Current OvervoltageCV Source Effect Transient Recovery TimeCV Noise Pard CC Load and Line Regulation CC SetupConstant Current CC Tests Current Programming/Readback AccuracyCC Source Effect CC Load EffectCC Noise Pard Measurement Uncertainty SpecificationPerformance Test Record for Model Agilent 66101A 8V, 16A Test DescriptionPerformance Test Record for Model Agilent 66102A 20V, 7.5A Actual Verification and Performance Tests Performance Test Record for Model Agilent 66103A 35V, 4.5APerformance Test Record for Model Agilent 66104A 60V, 2.5A 1μV 7mV 230μV 0mV 5mV 15mV 15μA 157μA 4μA Performance Test Record for Model Agilent 66106A 200V, 0.75A Page Accessing the Flowcharts Troubleshooting SequenceTroubleshooting Troubleshooting No Output If You Experienced Other Problems With the ModuleOverall Troubleshooting Sheet 1 Overall Troubleshooting Sheet 2 Overall Troubleshooting Sheet 3 Troubleshooting Microprocessor Circuits Sheet 1 Troubleshooting Microprocessor Circuits Sheet 2 Troubleshooting Error Messages Troubleshooting Overvoltage at Turn-On Sheet 1 Troubleshooting Overvoltage at Turn-On Sheet 2 Troubleshooting No Output Sheet 1 Troubleshooting No Output Sheet 2 Troubleshooting No Output Sheet 3 Troubleshooting No Output Sheet 4 Troubleshooting No Output Sheet 5 Troubleshooting High Output Troubleshooting Will Not Overvoltage Troubleshooting CV Accuracy Troubleshooting CC Accuracy 10. Troubleshooting Downprogrammer 11. Troubleshooting DAC Circuit 12. Troubleshooting Readback Circuits Sheet 1 12. Troubleshooting Readback Circuits Sheet 2 Built-In Test Functions Test PointsTest Point Test Points Description S3 Test Settings Test Description S3 Setting13. S3 Switch Setting Waveforms Troubleshooting Initialization Eeprom Troubleshooting and Initialization14. Eeprom Initialization Program Sheet 1 Troubleshooting 14. Eeprom Initialization Program Sheet 2 Troubleshooting 14. Eeprom Initialization Program Sheet 3 Troubleshooting 14. Eeprom Initialization Program Sheet 4 Troubleshooting Removing the Fan Disassembly ProceduresRemoving the Module and Module Connector Removing the CoverRemoving the Front Panel Board Removing the Front Panel AssemblyRemoving the Power Board Removing the Bias BoardInstalling the Bias Board Installing the Power BoardInstalling the Fan Installing the Front Panel Board and Front Panel AssemblyInstalling the Cover Page Theory Of Operation AC Input and Bias SuppliesMicroprocessor Circuits CV/CC DACsBlock Diagram Thoery Of Operation CC Amplifier CV AmplifierOr Gates Downprogrammer Circuit Pulse-Width Modulator, FETS, and Isolation TransformerReadback Multiplexer OV Circuit Page Replacement Parts Replacement PartsModel Model Model DIODE-PWR Rect CHOKE-OUTPUT BEAD-FERRITE CONNECTOR, Hood ASSY-FET, HS Shunt .005 Ohms Shunt .01 Ohms Shunt .035 Ohms R305 R306 R307 R308 R309 R310 R311 R312 R313 R314 R315 Model RES-ZERO Ohms RES 9.31K 1% Replacement Parts All Models 66101A-66103A 66104A-66106A Agilent 6610xA Power Modules Parts List Mechanical Model Output Connector Assembly Parts List Reference Designators Page Component Location Diagrams Schematic SheetsDiagrams Schematic Notes Page Page L305 Page Page Module Front Panel Page Page Page OUT Main Board Component Coordinates Page Backdating Agilent Prefix Serial Number Make Model ChangesAgilent Prefix Serial Number Make Number ChangesBackdating Index IndexSchematic Troubleshooting

6610XA specifications

Agilent Technologies has long been recognized for its innovative contributions to the fields of measurement and testing, and the Agilent 6610XA series of power supplies is no exception. Tailored for demanding applications in electronics and advanced research, the 6610XA series exemplifies cutting-edge technology blended with user-friendly features.

One of the main characteristics of the Agilent 6610XA is its ability to provide a stable, accurate, and reliable power supply across a range of applications. With output voltages that can reach as high as 60V and currents up to 10A, the device is versatile enough to cater to a variety of testing requirements. This power supply is ideal for applications including semiconductor testing, device characterization, and more, where precision and consistency are paramount.

Among the standout features of the Agilent 6610XA is its advanced graphical user interface (GUI), which enhances the overall user experience. The intuitive design allows engineers and technicians to monitor and control voltage and current settings easily, making the process of configuring the device both fast and efficient. Additionally, the device has built-in measurement capabilities that can display real-time voltage and current readings, significantly aiding in troubleshooting and performance evaluation.

Furthermore, the 6610XA incorporates a range of communication interfaces including USB, LAN, and GPIB, making it highly adaptable for integration into various automated test setups. This versatility signifies that the power supply can be seamlessly incorporated into existing laboratory environments, promoting productivity and efficiency.

The series also incorporates intelligent protection mechanisms to ensure both user safety and equipment longevity. Features such as overvoltage protection (OVP) and overcurrent protection (OCP) are designed to prevent accidental overloads, safeguarding both the device under test and the power supply itself.

Another key aspect is the series' capability to perform complex programming tasks with ease. With programming capabilities that enable users to set intricate voltage and current profiles, the device supports advanced applications, including load transient testing and sweep testing. This flexibility makes the Agilent 6610XA a valuable asset for any research and development environment looking to enhance testing efficiency and accuracy.

In conclusion, the Agilent 6610XA series power supply stands out for its combination of precision, user-friendliness, advanced communication capabilities, and safety features. These attributes make it a critical tool for engineers and researchers engaged in the rigorous demands of modern electronics testing and evaluation. With its continued commitment to innovation, Agilent Technologies reinforces its position as a leader in providing high-quality solutions for the measurement and testing industry.