Agilent Technologies 6610XA appendix Model

Page 69

Table 5-1. Agilent 6610xA Power Modules Parts List - Electrical (continued)

Reference

Designators

C303

C304

C305

C306, C307

C307

C308

C309A

C309B

C310

C311

C312, C313

C314, C315

C316

C317

C318

C319

C320

C321

C322

C323

C324, C325

C326, C327

C328

C329

C330

C331

Model

66101A

66102A

66103A

66104A

66105A

66106A

66101A

66102A

66103A

66104A

66105A

66106A

All Models

All Models

All Models

All Models

66101A-66103A

66104A-66106A

66101A

66102A, 66103A 66104A-66106A All Models 66101A, 66104A 66102A, 66103A 66105A 66106A

All Models

All Models

All Models

66101A, 66102A 66103A, 66104A 66105A 66106A

All Models

All Models

All Models

66101A

66102A-66106A

All Models

All Models

All Models

All Models

All Models

All Models

All Models

66101A, 66102A 66103A-66106A

Part Number

0180-4398

0180-4400

0180-4397

0180-3649

0180-3648

0180-3169

0180-4398

0180-4400

0180-4397

0180-3649

0180 3696

0180-3648

0160-4323

0160-4259

0160-4259

0160-4323

0160-7562

Not Used

0160-7562

Not Used

0160-5050

0160-4808

0160-4831

0160-7001

0160-4830

0160-7001

0160-4281

0160-4808

0160-4795

0160-4831

0160-6616

0160-4832

0160-5166

0160-4795

0160-5467

0160-4791

0160-5892

0160-5468

01604807

01605892

01604808

0160-5422

0160-4822

0160 5422

0160-4832

0160-4787

0160-4805

Description

CAP 470uF 63V

CAP 220uF 63V

CAP l00uF 63V

CAP 47uF l00VDC

CAP l0uF 250V

CAP 4.7uF 250VDC

CAP 470uF 63V

CAP 220uF 63V

CAP l00uF 63V

CAP 47uF 100V

CAP 22uF 250V

CAP l0uF 250V

CAP .047uF 20%

CAP .22uF 10%

CAP .22uF 10%

CAP .047uF 20%

CAP 6.8uF 63V

CAP 6.8uF 63V

CAP l.0uF 250V

CAP 470pF 5%

CAP 4700pF 10%

CAP 3300pF 100V

CAP 2200pF 10%

CAP 3300pF 100V

CAP 2200pF 20%

CAP 470pF 5%

CAP 4.7pF

CAP 4700pF 10%

CAP 6800pF 100V

CAP .0luF 10%

CAP .015uF 20%

CAP 4.7pF

CAP 0.0luF 63V

CAP l0pF 5% 100V

CAP .22uF 10%

CAP 0.47uF 50V

CAP 33pF 5% 100V

CAP .22uF 10%

CAP 470pF 5%

CAP .047uF 20%

CAP l000pF 5%

CAP .047uF 20%

CAP .0luF 10%

CAP 22pF 5% 100V

CAP 47pF 5% 100V

Replacement Parts 69

Image 69
Contents Agilent Part No Microfiche Part No Update June Service GuideCertification Safety Summary Printing History Table of Contents Replacement Parts Diagrams Overview About This ManualRelated Documents Revisions and Updates ManualFirmware Manual Part Number DescriptionSafety Considerations Service Tools and EquipmentElectrostatic Discharge Critical Specifications Service Test Equipment Equipment RequiredRecommended Model Use1Operation Verification Tests Performance TestsVerification and Performance Tests Measurement Techniques Setup for Most TestsProgramming Current-Monitoring ResistorConstant Voltage CV Tests CV SetupCurrent Overvoltage Voltage Programming/Readback AccuracyTransient Recovery Time CV Source EffectCV Noise Pard Constant Current CC Tests CC SetupCurrent Programming/Readback Accuracy CC Load and Line RegulationCC Source Effect CC Load EffectCC Noise Pard Performance Test Record for Model Agilent 66101A 8V, 16A SpecificationTest Description Measurement UncertaintyPerformance Test Record for Model Agilent 66102A 20V, 7.5A Actual Verification and Performance Tests Performance Test Record for Model Agilent 66103A 35V, 4.5APerformance Test Record for Model Agilent 66104A 60V, 2.5A 1μV 7mV 230μV 0mV 5mV 15mV 15μA 157μA 4μA Performance Test Record for Model Agilent 66106A 200V, 0.75A Page Troubleshooting Sequence Accessing the FlowchartsTroubleshooting Troubleshooting No Output If You Experienced Other Problems With the ModuleOverall Troubleshooting Sheet 1 Overall Troubleshooting Sheet 2 Overall Troubleshooting Sheet 3 Troubleshooting Microprocessor Circuits Sheet 1 Troubleshooting Microprocessor Circuits Sheet 2 Troubleshooting Error Messages Troubleshooting Overvoltage at Turn-On Sheet 1 Troubleshooting Overvoltage at Turn-On Sheet 2 Troubleshooting No Output Sheet 1 Troubleshooting No Output Sheet 2 Troubleshooting No Output Sheet 3 Troubleshooting No Output Sheet 4 Troubleshooting No Output Sheet 5 Troubleshooting High Output Troubleshooting Will Not Overvoltage Troubleshooting CV Accuracy Troubleshooting CC Accuracy 10. Troubleshooting Downprogrammer 11. Troubleshooting DAC Circuit 12. Troubleshooting Readback Circuits Sheet 1 12. Troubleshooting Readback Circuits Sheet 2 Test Points Built-In Test FunctionsTest Point Test Points Description S3 Test Settings Test Description S3 Setting13. S3 Switch Setting Waveforms Troubleshooting Initialization Eeprom Troubleshooting and Initialization14. Eeprom Initialization Program Sheet 1 Troubleshooting 14. Eeprom Initialization Program Sheet 2 Troubleshooting 14. Eeprom Initialization Program Sheet 3 Troubleshooting 14. Eeprom Initialization Program Sheet 4 Troubleshooting Removing the Module and Module Connector Disassembly ProceduresRemoving the Cover Removing the FanRemoving the Power Board Removing the Front Panel AssemblyRemoving the Bias Board Removing the Front Panel BoardInstalling the Bias Board Installing the Power BoardInstalling the Front Panel Board and Front Panel Assembly Installing the FanInstalling the Cover Page Microprocessor Circuits AC Input and Bias SuppliesCV/CC DACs Theory Of OperationBlock Diagram Thoery Of Operation CV Amplifier CC AmplifierOr Gates Pulse-Width Modulator, FETS, and Isolation Transformer Downprogrammer CircuitReadback Multiplexer OV Circuit Page Replacement Parts Replacement PartsModel Model Model DIODE-PWR Rect CHOKE-OUTPUT BEAD-FERRITE CONNECTOR, Hood ASSY-FET, HS Shunt .005 Ohms Shunt .01 Ohms Shunt .035 Ohms R305 R306 R307 R308 R309 R310 R311 R312 R313 R314 R315 Model RES-ZERO Ohms RES 9.31K 1% Replacement Parts All Models 66101A-66103A 66104A-66106A Agilent 6610xA Power Modules Parts List Mechanical Model Output Connector Assembly Parts List Reference Designators Page Schematic Sheets Component Location DiagramsDiagrams Schematic Notes Page Page L305 Page Page Module Front Panel Page Page Page OUT Main Board Component Coordinates Page Agilent Prefix Serial Number Make Agilent Prefix Serial Number Make Model ChangesNumber Changes BackdatingBackdating Index IndexSchematic Troubleshooting

6610XA specifications

Agilent Technologies has long been recognized for its innovative contributions to the fields of measurement and testing, and the Agilent 6610XA series of power supplies is no exception. Tailored for demanding applications in electronics and advanced research, the 6610XA series exemplifies cutting-edge technology blended with user-friendly features.

One of the main characteristics of the Agilent 6610XA is its ability to provide a stable, accurate, and reliable power supply across a range of applications. With output voltages that can reach as high as 60V and currents up to 10A, the device is versatile enough to cater to a variety of testing requirements. This power supply is ideal for applications including semiconductor testing, device characterization, and more, where precision and consistency are paramount.

Among the standout features of the Agilent 6610XA is its advanced graphical user interface (GUI), which enhances the overall user experience. The intuitive design allows engineers and technicians to monitor and control voltage and current settings easily, making the process of configuring the device both fast and efficient. Additionally, the device has built-in measurement capabilities that can display real-time voltage and current readings, significantly aiding in troubleshooting and performance evaluation.

Furthermore, the 6610XA incorporates a range of communication interfaces including USB, LAN, and GPIB, making it highly adaptable for integration into various automated test setups. This versatility signifies that the power supply can be seamlessly incorporated into existing laboratory environments, promoting productivity and efficiency.

The series also incorporates intelligent protection mechanisms to ensure both user safety and equipment longevity. Features such as overvoltage protection (OVP) and overcurrent protection (OCP) are designed to prevent accidental overloads, safeguarding both the device under test and the power supply itself.

Another key aspect is the series' capability to perform complex programming tasks with ease. With programming capabilities that enable users to set intricate voltage and current profiles, the device supports advanced applications, including load transient testing and sweep testing. This flexibility makes the Agilent 6610XA a valuable asset for any research and development environment looking to enhance testing efficiency and accuracy.

In conclusion, the Agilent 6610XA series power supply stands out for its combination of precision, user-friendliness, advanced communication capabilities, and safety features. These attributes make it a critical tool for engineers and researchers engaged in the rigorous demands of modern electronics testing and evaluation. With its continued commitment to innovation, Agilent Technologies reinforces its position as a leader in providing high-quality solutions for the measurement and testing industry.