Agilent Technologies 6610XA appendix Shunt .005 Ohms Shunt .01 Ohms Shunt .035 Ohms

Page 73

Table 5-1. Agilent 6610xA Power Modules Parts List - Electrical (continued)

Reference

Designators

R29

R201, R202

R203

R204

R205

R206, R208

R210, R211

R212

R213

R214

R215-R217

R218, R219

R220

R221

R222

R223

R224

R225

R228, R229

R232

R234

R235

R236

R237, R238

R239

R240

R241

R244

R245, R246

R247

R249

R250

R301, R302

R303

R304

Model

All Models

All Models

All Models

All Models

All Models

66101A-66103A

66104A-66106A

All Models

All Models

All Models

All Models

All Models

All Models

All Models

66101A-66103A

66104A-66106A

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

66101A, 66102A

66103A

66104A

66105A

66106A

66101A

66102A

66103A, 66104A

66105A

66106A

All Models

Part Number

0698-0082

0764-0045

0698-3430

0757-0403

0683-0335

0698-3445

0757-0407

0698-3631

0698-3430

0683-0335

0757-0403

0757-0442

0698-3432

1810-0203

0698-4470

0757-0290

0757-0449

0698-3446

0757-0442

0757-0279

0757-0442

0757-0442

0757-0401

0698-3279

0757-0430

0698-3631

0757-0442

0698-4406

0757-0283

0698-3159

0698-8827

0757-0280

0757-0462

0698-4099

0811-3896

0811-3897

0811-3896

0811-3891

0811-3892

5080-2217

5080-2218

5080-2224

0811-3771

0811-3772

0698-3279

Description

RES 464 1% .125W

RES 22K 5% 2W Mo

RES 21.5 1% .125W

RES 121 1% .125W

RES 3.3 5% .25W

RES 348 1% .125W

RES 200 1% .125W

RES 330 5% 2W Mo

RES 21.5 1%

RES 3.3 5% .25W

RES 121 1% .125W

RES l0K 1% .125W

RES 26.1 1%

NETWORK-RES SIP

RES 6.98K 1%

RES 6.19K 1%

RES 20K 1% .125W

RES 383 1% .125W

RES l0K 1% .125W

RES 3.16K 1%

RES l0K 1% .125W

RES l0K 1% .125W

RES 100 1% .125W

RES 4.99K 1%

RES 2.21K 1%

RES 330 5% 2W Mo

RES l0K 1% .125W

RES 115 1% .125W

RES 2K 1% .125W

RES 26.1K 1%

RES lM 1% .125W

RES lK 1% .125W

RES 75K 1% .125W

RES 139 1% .125W

RES 20 5% l0W

RES 62 5% l0W

RES 20 5% l0W

RES 75 5% l0W

RES 300 5% l0W

SHUNT .005 OHMS

SHUNT .01 OHMS

SHUNT .035 OHMS

RES .25 OHM 1%

RES .50 OHM 1%

RES 4.99K 1%

Replacement Parts 73

Image 73
Contents Agilent Part No Microfiche Part No Update June Service GuideCertification Safety Summary Printing History Table of Contents Replacement Parts Diagrams Overview About This ManualRelated Documents Revisions and Updates ManualFirmware Manual Part Number DescriptionService Tools and Equipment Safety ConsiderationsElectrostatic Discharge Critical Specifications Service Test Equipment Equipment RequiredRecommended Model Use1Performance Tests Operation Verification TestsVerification and Performance Tests Measurement Techniques Setup for Most TestsProgramming Current-Monitoring ResistorConstant Voltage CV Tests CV SetupCurrent Overvoltage Voltage Programming/Readback AccuracyCV Source Effect Transient Recovery TimeCV Noise Pard Constant Current CC Tests CC SetupCurrent Programming/Readback Accuracy CC Load and Line RegulationCC Source Effect CC Load EffectCC Noise Pard Performance Test Record for Model Agilent 66101A 8V, 16A SpecificationTest Description Measurement UncertaintyPerformance Test Record for Model Agilent 66102A 20V, 7.5A Actual Verification and Performance Tests Performance Test Record for Model Agilent 66103A 35V, 4.5APerformance Test Record for Model Agilent 66104A 60V, 2.5A 1μV 7mV 230μV 0mV 5mV 15mV 15μA 157μA 4μA Performance Test Record for Model Agilent 66106A 200V, 0.75A Page Accessing the Flowcharts Troubleshooting SequenceTroubleshooting Troubleshooting No Output If You Experienced Other Problems With the ModuleOverall Troubleshooting Sheet 1 Overall Troubleshooting Sheet 2 Overall Troubleshooting Sheet 3 Troubleshooting Microprocessor Circuits Sheet 1 Troubleshooting Microprocessor Circuits Sheet 2 Troubleshooting Error Messages Troubleshooting Overvoltage at Turn-On Sheet 1 Troubleshooting Overvoltage at Turn-On Sheet 2 Troubleshooting No Output Sheet 1 Troubleshooting No Output Sheet 2 Troubleshooting No Output Sheet 3 Troubleshooting No Output Sheet 4 Troubleshooting No Output Sheet 5 Troubleshooting High Output Troubleshooting Will Not Overvoltage Troubleshooting CV Accuracy Troubleshooting CC Accuracy 10. Troubleshooting Downprogrammer 11. Troubleshooting DAC Circuit 12. Troubleshooting Readback Circuits Sheet 1 12. Troubleshooting Readback Circuits Sheet 2 Built-In Test Functions Test PointsTest Point Test Points Description S3 Test Settings Test Description S3 Setting13. S3 Switch Setting Waveforms Troubleshooting Initialization Eeprom Troubleshooting and Initialization14. Eeprom Initialization Program Sheet 1 Troubleshooting 14. Eeprom Initialization Program Sheet 2 Troubleshooting 14. Eeprom Initialization Program Sheet 3 Troubleshooting 14. Eeprom Initialization Program Sheet 4 Troubleshooting Removing the Module and Module Connector Disassembly ProceduresRemoving the Cover Removing the FanRemoving the Power Board Removing the Front Panel AssemblyRemoving the Bias Board Removing the Front Panel BoardInstalling the Bias Board Installing the Power BoardInstalling the Fan Installing the Front Panel Board and Front Panel AssemblyInstalling the Cover Page Microprocessor Circuits AC Input and Bias SuppliesCV/CC DACs Theory Of OperationBlock Diagram Thoery Of Operation CC Amplifier CV AmplifierOr Gates Downprogrammer Circuit Pulse-Width Modulator, FETS, and Isolation TransformerReadback Multiplexer OV Circuit Page Replacement Parts Replacement PartsModel Model Model DIODE-PWR Rect CHOKE-OUTPUT BEAD-FERRITE CONNECTOR, Hood ASSY-FET, HS Shunt .005 Ohms Shunt .01 Ohms Shunt .035 Ohms R305 R306 R307 R308 R309 R310 R311 R312 R313 R314 R315 Model RES-ZERO Ohms RES 9.31K 1% Replacement Parts All Models 66101A-66103A 66104A-66106A Agilent 6610xA Power Modules Parts List Mechanical Model Output Connector Assembly Parts List Reference Designators Page Component Location Diagrams Schematic SheetsDiagrams Schematic Notes Page Page L305 Page Page Module Front Panel Page Page Page OUT Main Board Component Coordinates Page Agilent Prefix Serial Number Make Agilent Prefix Serial Number Make Model ChangesNumber Changes BackdatingBackdating Index IndexSchematic Troubleshooting

6610XA specifications

Agilent Technologies has long been recognized for its innovative contributions to the fields of measurement and testing, and the Agilent 6610XA series of power supplies is no exception. Tailored for demanding applications in electronics and advanced research, the 6610XA series exemplifies cutting-edge technology blended with user-friendly features.

One of the main characteristics of the Agilent 6610XA is its ability to provide a stable, accurate, and reliable power supply across a range of applications. With output voltages that can reach as high as 60V and currents up to 10A, the device is versatile enough to cater to a variety of testing requirements. This power supply is ideal for applications including semiconductor testing, device characterization, and more, where precision and consistency are paramount.

Among the standout features of the Agilent 6610XA is its advanced graphical user interface (GUI), which enhances the overall user experience. The intuitive design allows engineers and technicians to monitor and control voltage and current settings easily, making the process of configuring the device both fast and efficient. Additionally, the device has built-in measurement capabilities that can display real-time voltage and current readings, significantly aiding in troubleshooting and performance evaluation.

Furthermore, the 6610XA incorporates a range of communication interfaces including USB, LAN, and GPIB, making it highly adaptable for integration into various automated test setups. This versatility signifies that the power supply can be seamlessly incorporated into existing laboratory environments, promoting productivity and efficiency.

The series also incorporates intelligent protection mechanisms to ensure both user safety and equipment longevity. Features such as overvoltage protection (OVP) and overcurrent protection (OCP) are designed to prevent accidental overloads, safeguarding both the device under test and the power supply itself.

Another key aspect is the series' capability to perform complex programming tasks with ease. With programming capabilities that enable users to set intricate voltage and current profiles, the device supports advanced applications, including load transient testing and sweep testing. This flexibility makes the Agilent 6610XA a valuable asset for any research and development environment looking to enhance testing efficiency and accuracy.

In conclusion, the Agilent 6610XA series power supply stands out for its combination of precision, user-friendliness, advanced communication capabilities, and safety features. These attributes make it a critical tool for engineers and researchers engaged in the rigorous demands of modern electronics testing and evaluation. With its continued commitment to innovation, Agilent Technologies reinforces its position as a leader in providing high-quality solutions for the measurement and testing industry.