Agilent Technologies 6610XA appendix Troubleshooting No Output Sheet 2

Page 36

Figure 3-5. Troubleshooting No Output (Sheet 2 of 5)

36 Troubleshooting

Image 36
Contents Service Guide Agilent Part No Microfiche Part No Update JuneCertification Safety Summary Printing History Table of Contents Replacement Parts Diagrams About This Manual OverviewRevisions and Updates Manual Related DocumentsFirmware Manual Part Number DescriptionSafety Considerations Service Tools and EquipmentElectrostatic Discharge Service Test Equipment Equipment Required Critical SpecificationsRecommended Model Use1Operation Verification Tests Performance TestsVerification and Performance Tests Setup for Most Tests Measurement TechniquesProgramming Current-Monitoring ResistorCV Setup Constant Voltage CV TestsCurrent Overvoltage Voltage Programming/Readback AccuracyTransient Recovery Time CV Source EffectCV Noise Pard CC Setup Constant Current CC TestsCurrent Programming/Readback Accuracy CC Load and Line RegulationCC Load Effect CC Source EffectCC Noise Pard Specification Performance Test Record for Model Agilent 66101A 8V, 16ATest Description Measurement UncertaintyPerformance Test Record for Model Agilent 66102A 20V, 7.5A Performance Test Record for Model Agilent 66103A 35V, 4.5A Actual Verification and Performance TestsPerformance Test Record for Model Agilent 66104A 60V, 2.5A 1μV 7mV 230μV 0mV 5mV 15mV 15μA 157μA 4μA Performance Test Record for Model Agilent 66106A 200V, 0.75A Page Troubleshooting Sequence Accessing the FlowchartsTroubleshooting If You Experienced Other Problems With the Module Troubleshooting No OutputOverall Troubleshooting Sheet 1 Overall Troubleshooting Sheet 2 Overall Troubleshooting Sheet 3 Troubleshooting Microprocessor Circuits Sheet 1 Troubleshooting Microprocessor Circuits Sheet 2 Troubleshooting Error Messages Troubleshooting Overvoltage at Turn-On Sheet 1 Troubleshooting Overvoltage at Turn-On Sheet 2 Troubleshooting No Output Sheet 1 Troubleshooting No Output Sheet 2 Troubleshooting No Output Sheet 3 Troubleshooting No Output Sheet 4 Troubleshooting No Output Sheet 5 Troubleshooting High Output Troubleshooting Will Not Overvoltage Troubleshooting CV Accuracy Troubleshooting CC Accuracy 10. Troubleshooting Downprogrammer 11. Troubleshooting DAC Circuit 12. Troubleshooting Readback Circuits Sheet 1 12. Troubleshooting Readback Circuits Sheet 2 Test Points Built-In Test FunctionsTest Point Test Points Description S3 Setting S3 Test Settings Test Description13. S3 Switch Setting Waveforms Troubleshooting Eeprom Troubleshooting and Initialization Initialization14. Eeprom Initialization Program Sheet 1 Troubleshooting 14. Eeprom Initialization Program Sheet 2 Troubleshooting 14. Eeprom Initialization Program Sheet 3 Troubleshooting 14. Eeprom Initialization Program Sheet 4 Troubleshooting Disassembly Procedures Removing the Module and Module ConnectorRemoving the Cover Removing the FanRemoving the Front Panel Assembly Removing the Power BoardRemoving the Bias Board Removing the Front Panel BoardInstalling the Power Board Installing the Bias BoardInstalling the Front Panel Board and Front Panel Assembly Installing the FanInstalling the Cover Page AC Input and Bias Supplies Microprocessor CircuitsCV/CC DACs Theory Of OperationBlock Diagram Thoery Of Operation CV Amplifier CC AmplifierOr Gates Pulse-Width Modulator, FETS, and Isolation Transformer Downprogrammer CircuitReadback Multiplexer OV Circuit Page Replacement Parts Replacement PartsModel Model Model DIODE-PWR Rect CHOKE-OUTPUT BEAD-FERRITE CONNECTOR, Hood ASSY-FET, HS Shunt .005 Ohms Shunt .01 Ohms Shunt .035 Ohms R305 R306 R307 R308 R309 R310 R311 R312 R313 R314 R315 Model RES-ZERO Ohms RES 9.31K 1% Replacement Parts All Models 66101A-66103A 66104A-66106A Agilent 6610xA Power Modules Parts List Mechanical Model Output Connector Assembly Parts List Reference Designators Page Schematic Sheets Component Location DiagramsDiagrams Schematic Notes Page Page L305 Page Page Module Front Panel Page Page Page OUT Main Board Component Coordinates Page Agilent Prefix Serial Number Make Model Changes Agilent Prefix Serial Number MakeNumber Changes BackdatingBackdating Index IndexSchematic Troubleshooting

6610XA specifications

Agilent Technologies has long been recognized for its innovative contributions to the fields of measurement and testing, and the Agilent 6610XA series of power supplies is no exception. Tailored for demanding applications in electronics and advanced research, the 6610XA series exemplifies cutting-edge technology blended with user-friendly features.

One of the main characteristics of the Agilent 6610XA is its ability to provide a stable, accurate, and reliable power supply across a range of applications. With output voltages that can reach as high as 60V and currents up to 10A, the device is versatile enough to cater to a variety of testing requirements. This power supply is ideal for applications including semiconductor testing, device characterization, and more, where precision and consistency are paramount.

Among the standout features of the Agilent 6610XA is its advanced graphical user interface (GUI), which enhances the overall user experience. The intuitive design allows engineers and technicians to monitor and control voltage and current settings easily, making the process of configuring the device both fast and efficient. Additionally, the device has built-in measurement capabilities that can display real-time voltage and current readings, significantly aiding in troubleshooting and performance evaluation.

Furthermore, the 6610XA incorporates a range of communication interfaces including USB, LAN, and GPIB, making it highly adaptable for integration into various automated test setups. This versatility signifies that the power supply can be seamlessly incorporated into existing laboratory environments, promoting productivity and efficiency.

The series also incorporates intelligent protection mechanisms to ensure both user safety and equipment longevity. Features such as overvoltage protection (OVP) and overcurrent protection (OCP) are designed to prevent accidental overloads, safeguarding both the device under test and the power supply itself.

Another key aspect is the series' capability to perform complex programming tasks with ease. With programming capabilities that enable users to set intricate voltage and current profiles, the device supports advanced applications, including load transient testing and sweep testing. This flexibility makes the Agilent 6610XA a valuable asset for any research and development environment looking to enhance testing efficiency and accuracy.

In conclusion, the Agilent 6610XA series power supply stands out for its combination of precision, user-friendliness, advanced communication capabilities, and safety features. These attributes make it a critical tool for engineers and researchers engaged in the rigorous demands of modern electronics testing and evaluation. With its continued commitment to innovation, Agilent Technologies reinforces its position as a leader in providing high-quality solutions for the measurement and testing industry.