Agilent Technologies 6610XA appendix RES 9.31K 1%

Page 77

Table 5-1. Agilent 6610xA Power Modules Parts List - Electrical (continued)

Reference

Designators

R348

R349

R350

R351

R352

R353

R354

R355

R359

R360

R361

R362

R363

R364

R365

R367

R368, R369

R401

R402

R406

R407, R408

R409-R411

R416

R419

Model

66101A, 66102A 66103A, 66104A 66105A 66106A

All Models

66101A-66105A

66106A

All Models

All Models

66101A

66102A

66103A

66104A

66105A, 66106A

All Models

All Models

66101A-66103A

66104A

66105A

66106A

66101A

66102A

66103A

66104A

66105A

66106A

66101A

66102A

66103A, 66104A

66105A

66106A

All Models

All Models

All Models

All Models

66101A, 66102A 66103A-66105A 66106A 66101A, 66102A 66103A-66106A All Models

AU Models

All Models

All Models

All Models

All Models

All Models

Part Number

0757-0441

0757-0444

0698-3136

0698-3159

0757-0472

8159-0005

0698-6358

0699-2246

0683-2255

0698-4443

0757-0349

0757-0467

0698-6376

Not Used

0757-0283

0757-0442

0698-6360

0698-6320

0698-6360

0698-8061

0698-4196

8159-0005

0698-0064

8159-0005

0698-7841

0698-6376

0698-6619

0699-2248

0698-6359

0698-7841

0698-8050

0757-0465

0699-2246

0698-3279

0698-6358

0698-8812

Not Used

0757-0346

0698-8812

Not Used

0699-1069

0699-0486

0757-0437

0757-0407

0757-0280

8159-0005

0757-0449

Description

RES 8.25K 1%

RES 12.1K 1%

RES 17.8K 1%

RES 26.1K 1%

RES 200K 1%

RES-ZERO OHMS

RES 100K .1%

RES 25K .05%

RES 2.2M 5% .25W

RES 4.53K 1%

RES 22.6K 1%

RES 121K 1%

RES 200K .1%

RES 2K 1% .125W

RES l0K 1% .125W

RES l0K .1%

RES 5K .1% .125W

RES 10K .1%

RES 8.25K .1%

RES 1.07K 1%

RES-ZERO OHMS

RES 9.31K 1%

RES-ZERO OHMS

RES 164K .1%

RES 200K .1%

RES 15K .1%

RES 47.5K .05%

RES 80K 0.l%

RES 164K .1%

RES 256K .1%

RES 100K 1%

RES 25K .05%

RES 4.99K 1%

RES 100K .1%

RES 1 1% .125W

RES 10 1% .125W

RES 1 1% .125W

RES 229 .1%

RES 2K .1% .lW F

RES 4.75K 1%

RES 200 1% .125W

RES lK 1% .125W

RES-ZERO OHMS

RES 20K 1% .125W

Replacement Parts 77

Image 77
Contents Agilent Part No Microfiche Part No Update June Service GuideCertification Safety Summary Printing History Table of Contents Replacement Parts Diagrams Overview About This ManualRelated Documents Revisions and Updates ManualFirmware Manual Part Number DescriptionElectrostatic Discharge Safety ConsiderationsService Tools and Equipment Critical Specifications Service Test Equipment Equipment RequiredRecommended Model Use1Verification and Performance Tests Operation Verification TestsPerformance Tests Measurement Techniques Setup for Most TestsProgramming Current-Monitoring ResistorConstant Voltage CV Tests CV SetupCurrent Overvoltage Voltage Programming/Readback AccuracyCV Noise Pard Transient Recovery TimeCV Source Effect Constant Current CC Tests CC SetupCurrent Programming/Readback Accuracy CC Load and Line RegulationCC Source Effect CC Load EffectCC Noise Pard Performance Test Record for Model Agilent 66101A 8V, 16A SpecificationTest Description Measurement UncertaintyPerformance Test Record for Model Agilent 66102A 20V, 7.5A Actual Verification and Performance Tests Performance Test Record for Model Agilent 66103A 35V, 4.5APerformance Test Record for Model Agilent 66104A 60V, 2.5A 1μV 7mV 230μV 0mV 5mV 15mV 15μA 157μA 4μA Performance Test Record for Model Agilent 66106A 200V, 0.75A Page Troubleshooting Troubleshooting SequenceAccessing the Flowcharts Troubleshooting No Output If You Experienced Other Problems With the ModuleOverall Troubleshooting Sheet 1 Overall Troubleshooting Sheet 2 Overall Troubleshooting Sheet 3 Troubleshooting Microprocessor Circuits Sheet 1 Troubleshooting Microprocessor Circuits Sheet 2 Troubleshooting Error Messages Troubleshooting Overvoltage at Turn-On Sheet 1 Troubleshooting Overvoltage at Turn-On Sheet 2 Troubleshooting No Output Sheet 1 Troubleshooting No Output Sheet 2 Troubleshooting No Output Sheet 3 Troubleshooting No Output Sheet 4 Troubleshooting No Output Sheet 5 Troubleshooting High Output Troubleshooting Will Not Overvoltage Troubleshooting CV Accuracy Troubleshooting CC Accuracy 10. Troubleshooting Downprogrammer 11. Troubleshooting DAC Circuit 12. Troubleshooting Readback Circuits Sheet 1 12. Troubleshooting Readback Circuits Sheet 2 Test Point Test Points Description Test PointsBuilt-In Test Functions S3 Test Settings Test Description S3 Setting13. S3 Switch Setting Waveforms Troubleshooting Initialization Eeprom Troubleshooting and Initialization14. Eeprom Initialization Program Sheet 1 Troubleshooting 14. Eeprom Initialization Program Sheet 2 Troubleshooting 14. Eeprom Initialization Program Sheet 3 Troubleshooting 14. Eeprom Initialization Program Sheet 4 Troubleshooting Removing the Module and Module Connector Disassembly ProceduresRemoving the Cover Removing the FanRemoving the Power Board Removing the Front Panel AssemblyRemoving the Bias Board Removing the Front Panel BoardInstalling the Bias Board Installing the Power BoardInstalling the Cover Installing the Front Panel Board and Front Panel AssemblyInstalling the Fan Page Microprocessor Circuits AC Input and Bias SuppliesCV/CC DACs Theory Of OperationBlock Diagram Thoery Of Operation Or Gates CV AmplifierCC Amplifier Readback Multiplexer Pulse-Width Modulator, FETS, and Isolation TransformerDownprogrammer Circuit OV Circuit Page Replacement Parts Replacement PartsModel Model Model DIODE-PWR Rect CHOKE-OUTPUT BEAD-FERRITE CONNECTOR, Hood ASSY-FET, HS Shunt .005 Ohms Shunt .01 Ohms Shunt .035 Ohms R305 R306 R307 R308 R309 R310 R311 R312 R313 R314 R315 Model RES-ZERO Ohms RES 9.31K 1% Replacement Parts All Models 66101A-66103A 66104A-66106A Agilent 6610xA Power Modules Parts List Mechanical Model Output Connector Assembly Parts List Reference Designators Page Diagrams Schematic SheetsComponent Location Diagrams Schematic Notes Page Page L305 Page Page Module Front Panel Page Page Page OUT Main Board Component Coordinates Page Agilent Prefix Serial Number Make Agilent Prefix Serial Number Make Model ChangesNumber Changes BackdatingBackdating Index IndexSchematic Troubleshooting

6610XA specifications

Agilent Technologies has long been recognized for its innovative contributions to the fields of measurement and testing, and the Agilent 6610XA series of power supplies is no exception. Tailored for demanding applications in electronics and advanced research, the 6610XA series exemplifies cutting-edge technology blended with user-friendly features.

One of the main characteristics of the Agilent 6610XA is its ability to provide a stable, accurate, and reliable power supply across a range of applications. With output voltages that can reach as high as 60V and currents up to 10A, the device is versatile enough to cater to a variety of testing requirements. This power supply is ideal for applications including semiconductor testing, device characterization, and more, where precision and consistency are paramount.

Among the standout features of the Agilent 6610XA is its advanced graphical user interface (GUI), which enhances the overall user experience. The intuitive design allows engineers and technicians to monitor and control voltage and current settings easily, making the process of configuring the device both fast and efficient. Additionally, the device has built-in measurement capabilities that can display real-time voltage and current readings, significantly aiding in troubleshooting and performance evaluation.

Furthermore, the 6610XA incorporates a range of communication interfaces including USB, LAN, and GPIB, making it highly adaptable for integration into various automated test setups. This versatility signifies that the power supply can be seamlessly incorporated into existing laboratory environments, promoting productivity and efficiency.

The series also incorporates intelligent protection mechanisms to ensure both user safety and equipment longevity. Features such as overvoltage protection (OVP) and overcurrent protection (OCP) are designed to prevent accidental overloads, safeguarding both the device under test and the power supply itself.

Another key aspect is the series' capability to perform complex programming tasks with ease. With programming capabilities that enable users to set intricate voltage and current profiles, the device supports advanced applications, including load transient testing and sweep testing. This flexibility makes the Agilent 6610XA a valuable asset for any research and development environment looking to enhance testing efficiency and accuracy.

In conclusion, the Agilent 6610XA series power supply stands out for its combination of precision, user-friendliness, advanced communication capabilities, and safety features. These attributes make it a critical tool for engineers and researchers engaged in the rigorous demands of modern electronics testing and evaluation. With its continued commitment to innovation, Agilent Technologies reinforces its position as a leader in providing high-quality solutions for the measurement and testing industry.