Table 5-1. Agilent 6610xA Power Modules Parts List - Electrical (continued)

Reference

Designators

C332, C333

C334

C335

C336

C337

C338-C341

C342

C343

C346

C347

C349

C358

C395

C396

C397

C403

C404

C407

C408-C410

C411-C413

C414, C415

C416

C418

C420-C425

C427A

C427B

C427B

C428, C429

C430

C431, C432

Model

All Models

All Models

66101A

66102A-66106A 66101A, 66102A 66103A-66106A All Models

All Models

All Models

66101A-66104A

66105A

66106A

66101A

66102A

66103A, 66104A

66105A

66106A

66101A

66102A-66104A

66105A

66106A

66101A-66105A

66106A

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

All Models

66101A-66103A

66104A

66105A, 66106A 66101A-66103A 66104A 66105A, 66106A 66101A-66104A 66105A, 66106A 66101A-66106A All Models

Part Number

0160-5422

0160-4807

0160-4831

0160-4830

0160-4787

0160-4805

0160-4830

0160-5422

0160-5892

0160-4831

0160-4833

0160-7001

0160-4832

0160-6616

0160-4832

0160-4833

0160-4832

0160-4801

0160-4803

0160-4813

0160-4803

0160-4812

0160-4808

0160-4830

0180-4129

0160-7578

0160-4835

0160-4183

0160-5422

0180-4136

0180-4129

0160-4835

0160-4822

0160-4808

0160-5422

0160-5422

0160-4835

0160-4834

Not Used Not Used 0160-4834 0160-0269 Not Used 0160-0269 Not Used 0160-5422

Description

CAP .047uF 20%

CAP 33pF 5% 100V

CAP 4700pF 10%

CAP 2200pF 10%

CAP 22pF 5% 100V

CAP 47pF 5% 100V

CAP 2200pF 10%

CAP .047uF 20%

CAP .22uF 10%

CAP 4700pF 10%

CAP .022uF l0%

CAP 3300pF 100V

CAP .0luF 10%

CAP 6800pF 100V

CAP .0luF 10%

CAP .022uF 10%

CAP .0luF 10%

CAP l00pF 5%

CAP 68pF 5% 100V

CAP 180pF 5%

CAP 68pF 5% 100V

CAP 220pF 5%

CAP 470pF 5%

CAP 2200pF 10%

CAP luF 35V

CAP 330pF 630VDC

CAP .luF 10% 50V

CAP l000pF 20%

CAP .047uF 20%

CAP l0uF 20V

CAP luF 35V

CAP .luF 10% 50V

CAP l000pF 5%

CAP 470pF 5%

CAP .047uF 20%

CAP .047uF 20%

CAP .luF 10% 50V

CAP .047uF 10%

CAP .047uF 10%

CAP .luF 20%

CAP .luF 20%

CAP .047uF 20%

70 Replacement Parts

Image 70
Contents Service Guide Agilent Part No Microfiche Part No Update JuneCertification Safety Summary Printing History Table of Contents Replacement Parts Diagrams About This Manual OverviewFirmware Revisions and Updates ManualRelated Documents Manual Part Number DescriptionService Tools and Equipment Safety ConsiderationsElectrostatic Discharge Recommended Model Service Test Equipment Equipment RequiredCritical Specifications Use1Performance Tests Operation Verification TestsVerification and Performance Tests Programming Setup for Most TestsMeasurement Techniques Current-Monitoring ResistorCurrent Overvoltage CV SetupConstant Voltage CV Tests Voltage Programming/Readback AccuracyCV Source Effect Transient Recovery TimeCV Noise Pard Current Programming/Readback Accuracy CC SetupConstant Current CC Tests CC Load and Line RegulationCC Load Effect CC Source EffectCC Noise Pard Test Description SpecificationPerformance Test Record for Model Agilent 66101A 8V, 16A Measurement UncertaintyPerformance Test Record for Model Agilent 66102A 20V, 7.5A Performance Test Record for Model Agilent 66103A 35V, 4.5A Actual Verification and Performance TestsPerformance Test Record for Model Agilent 66104A 60V, 2.5A 1μV 7mV 230μV 0mV 5mV 15mV 15μA 157μA 4μA Performance Test Record for Model Agilent 66106A 200V, 0.75A Page Accessing the Flowcharts Troubleshooting SequenceTroubleshooting If You Experienced Other Problems With the Module Troubleshooting No OutputOverall Troubleshooting Sheet 1 Overall Troubleshooting Sheet 2 Overall Troubleshooting Sheet 3 Troubleshooting Microprocessor Circuits Sheet 1 Troubleshooting Microprocessor Circuits Sheet 2 Troubleshooting Error Messages Troubleshooting Overvoltage at Turn-On Sheet 1 Troubleshooting Overvoltage at Turn-On Sheet 2 Troubleshooting No Output Sheet 1 Troubleshooting No Output Sheet 2 Troubleshooting No Output Sheet 3 Troubleshooting No Output Sheet 4 Troubleshooting No Output Sheet 5 Troubleshooting High Output Troubleshooting Will Not Overvoltage Troubleshooting CV Accuracy Troubleshooting CC Accuracy 10. Troubleshooting Downprogrammer 11. Troubleshooting DAC Circuit 12. Troubleshooting Readback Circuits Sheet 1 12. Troubleshooting Readback Circuits Sheet 2 Built-In Test Functions Test PointsTest Point Test Points Description S3 Setting S3 Test Settings Test Description13. S3 Switch Setting Waveforms Troubleshooting Eeprom Troubleshooting and Initialization Initialization14. Eeprom Initialization Program Sheet 1 Troubleshooting 14. Eeprom Initialization Program Sheet 2 Troubleshooting 14. Eeprom Initialization Program Sheet 3 Troubleshooting 14. Eeprom Initialization Program Sheet 4 Troubleshooting Removing the Cover Disassembly ProceduresRemoving the Module and Module Connector Removing the FanRemoving the Bias Board Removing the Front Panel AssemblyRemoving the Power Board Removing the Front Panel BoardInstalling the Power Board Installing the Bias BoardInstalling the Fan Installing the Front Panel Board and Front Panel AssemblyInstalling the Cover Page CV/CC DACs AC Input and Bias SuppliesMicroprocessor Circuits Theory Of OperationBlock Diagram Thoery Of Operation CC Amplifier CV AmplifierOr Gates Downprogrammer Circuit Pulse-Width Modulator, FETS, and Isolation TransformerReadback Multiplexer OV Circuit Page Replacement Parts Replacement PartsModel Model Model DIODE-PWR Rect CHOKE-OUTPUT BEAD-FERRITE CONNECTOR, Hood ASSY-FET, HS Shunt .005 Ohms Shunt .01 Ohms Shunt .035 Ohms R305 R306 R307 R308 R309 R310 R311 R312 R313 R314 R315 Model RES-ZERO Ohms RES 9.31K 1% Replacement Parts All Models 66101A-66103A 66104A-66106A Agilent 6610xA Power Modules Parts List Mechanical Model Output Connector Assembly Parts List Reference Designators Page Component Location Diagrams Schematic SheetsDiagrams Schematic Notes Page Page L305 Page Page Module Front Panel Page Page Page OUT Main Board Component Coordinates Page Number Changes Agilent Prefix Serial Number Make Model ChangesAgilent Prefix Serial Number Make BackdatingBackdating Index IndexSchematic Troubleshooting

6610XA specifications

Agilent Technologies has long been recognized for its innovative contributions to the fields of measurement and testing, and the Agilent 6610XA series of power supplies is no exception. Tailored for demanding applications in electronics and advanced research, the 6610XA series exemplifies cutting-edge technology blended with user-friendly features.

One of the main characteristics of the Agilent 6610XA is its ability to provide a stable, accurate, and reliable power supply across a range of applications. With output voltages that can reach as high as 60V and currents up to 10A, the device is versatile enough to cater to a variety of testing requirements. This power supply is ideal for applications including semiconductor testing, device characterization, and more, where precision and consistency are paramount.

Among the standout features of the Agilent 6610XA is its advanced graphical user interface (GUI), which enhances the overall user experience. The intuitive design allows engineers and technicians to monitor and control voltage and current settings easily, making the process of configuring the device both fast and efficient. Additionally, the device has built-in measurement capabilities that can display real-time voltage and current readings, significantly aiding in troubleshooting and performance evaluation.

Furthermore, the 6610XA incorporates a range of communication interfaces including USB, LAN, and GPIB, making it highly adaptable for integration into various automated test setups. This versatility signifies that the power supply can be seamlessly incorporated into existing laboratory environments, promoting productivity and efficiency.

The series also incorporates intelligent protection mechanisms to ensure both user safety and equipment longevity. Features such as overvoltage protection (OVP) and overcurrent protection (OCP) are designed to prevent accidental overloads, safeguarding both the device under test and the power supply itself.

Another key aspect is the series' capability to perform complex programming tasks with ease. With programming capabilities that enable users to set intricate voltage and current profiles, the device supports advanced applications, including load transient testing and sweep testing. This flexibility makes the Agilent 6610XA a valuable asset for any research and development environment looking to enhance testing efficiency and accuracy.

In conclusion, the Agilent 6610XA series power supply stands out for its combination of precision, user-friendliness, advanced communication capabilities, and safety features. These attributes make it a critical tool for engineers and researchers engaged in the rigorous demands of modern electronics testing and evaluation. With its continued commitment to innovation, Agilent Technologies reinforces its position as a leader in providing high-quality solutions for the measurement and testing industry.