Agilent Technologies 6610XA appendix Model

Page 75

Table 5-1. Agilent 6610xA Power Modules Parts List - Electrical (continued)

Reference

Designators

R316

R317

R318

R319, R320

R321

R322

R323

R323A

R323B

R324

R325

R326

R327, R328

R329, R330

R331

R332

R333

Model

All Models

All Models

All Models

All Models

All Models

All Models

66101A

66102A

66103A-66105A

66106A

66101A,66102A

66103A

66104A

66105A

66106A

66101A,66102A

66103A

66104A

66105A,66106A

All Models

66101A-66105A

66106A

All Models

66101A

66102A

66103A

66104A

66105A

66106A

All Models

66101A

66102A

66103A

66104A

66105A

66106A

66101A

66102A

66103A

66104A

66105A

66106A

66101A

66102A, 66103A

66104A

66105A

66106A

Part Number

0698-8827

0757-0472

0757-0349

0699-2246

0699-2248

0699-0070

0811-2568

0811-2455

Not Used

0698-3433

Not Used

0698-8822

0698-4356

0757-0382

Not Used Not Used 0698-8822 0698-4356 Not Used 0757-0283 0699-3415 0699-3417 0699-3415 0699-3103 0699-2248 0699-2879 0699-3446 0699-3104 0699-3448 0757-0280 0698-6362 0698-6631 0698-8184 0699-2246 0698-6353 0699-3447 0698-6362 0698-6631 0698-8184 0699-2246 0698-6353 0698-6358 0698-3159 0757-0442 0757-0443 0757-0441 0757-0447

Description

RES lM 1% .125W

RES 200K 1%

RES 22.6K 1%

RES 25K .05%

RES 47.5K .05%

RES 3.16M 1%

RES 1 1% 3W

RES 2 1% 3W

RES 28.7 1%

RES 6.81 1%

RES 12.7 1%

RES 16.2 1%

RES 6.81 1%

RES 12.7 1%

RES 2K 1% .125W

RES 5K .lW .05% RES 3.85K .lW RES 5K .lW .05% RES 19K .05% RES 47.5K .05%

RES 80K .05% 5PPM .lW RES 125K .05%

RES 250K .125W

RES 300K .05% RES lK 1% .125W RES lK .1% .125W RES 2.5K .1% RES 7.5K 1% RES 25K .05% RES 50K .1% RES 85K .1% RES lK .1% .125W RES 2.5K .1% RES 7.5K 1% RES 25K .05% RES 50K .1% RES 100K .1% RES 26.1K 1% RES l0K 1% .125W RES 11K 1% .125W RES 8.25K 1% RES 16.2K 1%

Replacement Parts 75

Image 75 Contents
Agilent Part No Microfiche Part No Update June Service GuideCertification Safety Summary Printing History Table of Contents Replacement Parts Diagrams Overview About This ManualManual Part Number Description Revisions and Updates ManualRelated Documents FirmwareSafety Considerations Service Tools and EquipmentElectrostatic Discharge Use1 Service Test Equipment Equipment RequiredCritical Specifications Recommended ModelOperation Verification Tests Performance TestsVerification and Performance Tests Current-Monitoring Resistor Setup for Most TestsMeasurement Techniques ProgrammingVoltage Programming/Readback Accuracy CV SetupConstant Voltage CV Tests Current OvervoltageTransient Recovery Time CV Source EffectCV Noise Pard CC Load and Line Regulation CC SetupConstant Current CC Tests Current Programming/Readback AccuracyCC Source Effect CC Load EffectCC Noise Pard Measurement Uncertainty SpecificationPerformance Test Record for Model Agilent 66101A 8V, 16A Test DescriptionPerformance Test Record for Model Agilent 66102A 20V, 7.5A Actual Verification and Performance Tests Performance Test Record for Model Agilent 66103A 35V, 4.5APerformance Test Record for Model Agilent 66104A 60V, 2.5A 1μV 7mV 230μV 0mV 5mV 15mV 15μA 157μA 4μA Performance Test Record for Model Agilent 66106A 200V, 0.75A Page Troubleshooting Sequence Accessing the FlowchartsTroubleshooting Troubleshooting No Output If You Experienced Other Problems With the ModuleOverall Troubleshooting Sheet 1 Overall Troubleshooting Sheet 2 Overall Troubleshooting Sheet 3 Troubleshooting Microprocessor Circuits Sheet 1 Troubleshooting Microprocessor Circuits Sheet 2 Troubleshooting Error Messages Troubleshooting Overvoltage at Turn-On Sheet 1 Troubleshooting Overvoltage at Turn-On Sheet 2 Troubleshooting No Output Sheet 1 Troubleshooting No Output Sheet 2 Troubleshooting No Output Sheet 3 Troubleshooting No Output Sheet 4 Troubleshooting No Output Sheet 5 Troubleshooting High Output Troubleshooting Will Not Overvoltage Troubleshooting CV Accuracy Troubleshooting CC Accuracy 10. Troubleshooting Downprogrammer 11. Troubleshooting DAC Circuit 12. Troubleshooting Readback Circuits Sheet 1 12. Troubleshooting Readback Circuits Sheet 2 Test Points Built-In Test FunctionsTest Point Test Points Description S3 Test Settings Test Description S3 Setting13. S3 Switch Setting Waveforms Troubleshooting Initialization Eeprom Troubleshooting and Initialization14. Eeprom Initialization Program Sheet 1 Troubleshooting 14. Eeprom Initialization Program Sheet 2 Troubleshooting 14. Eeprom Initialization Program Sheet 3 Troubleshooting 14. Eeprom Initialization Program Sheet 4 Troubleshooting Removing the Fan Disassembly ProceduresRemoving the Module and Module Connector Removing the CoverRemoving the Front Panel Board Removing the Front Panel AssemblyRemoving the Power Board Removing the Bias BoardInstalling the Bias Board Installing the Power BoardInstalling the Front Panel Board and Front Panel Assembly Installing the FanInstalling the Cover Page Theory Of Operation AC Input and Bias SuppliesMicroprocessor Circuits CV/CC DACsBlock Diagram Thoery Of Operation CV Amplifier CC AmplifierOr Gates Pulse-Width Modulator, FETS, and Isolation Transformer Downprogrammer CircuitReadback Multiplexer OV Circuit Page Replacement Parts Replacement PartsModel Model Model DIODE-PWR Rect CHOKE-OUTPUT BEAD-FERRITE CONNECTOR, Hood ASSY-FET, HS Shunt .005 Ohms Shunt .01 Ohms Shunt .035 Ohms R305 R306 R307 R308 R309 R310 R311 R312 R313 R314 R315 Model RES-ZERO Ohms RES 9.31K 1% Replacement Parts All Models 66101A-66103A 66104A-66106A Agilent 6610xA Power Modules Parts List Mechanical Model Output Connector Assembly Parts List Reference Designators Page Schematic Sheets Component Location DiagramsDiagrams Schematic Notes Page Page L305 Page Page Module Front Panel Page Page Page OUT Main Board Component Coordinates Page Backdating Agilent Prefix Serial Number Make Model ChangesAgilent Prefix Serial Number Make Number ChangesBackdating Index IndexSchematic Troubleshooting