Hearth and Home Technologies 6000BE Venting with TWO 2 90 o Elbows, Venting with Two 90 Elbows

Page 18

VENTING WITH TWO (2)

90° ELBOWS

H1

V

H

V

H

H + H1

1´ MIN. (305 mm)

2´ MAX. (610 mm)

5´ MAX. (1.52m)

2´ MIN. (610 mm)

4´ MAX. (1.22 m)

10´ MAX. (3.1m)

3´ MIN. (914 mm)

6´ MAX. (1.86 m)

15´ MAX. (4.65m)

4´ MIN. (1.22 m)

8´ MAX. (2.48 m)

20´ MAX. (6.2m)

V+H+H1 = 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m)

H+H1 = 20´ MAX. (6.2m)

Figure 14. Venting with Two 90° Elbows

VENTING WITH TWO (2) 90o ELBOWS

 

V FT.

(305mm)

H + H1 (FT.)

 

1' MIN.

5´ MAX. (1.52m)

 

2' MIN.

(610mm)

10´ MAX. (3.1m)

 

3' MIN.

(914mm)

15´ MAX. (4.65m)

 

4' MIN.

(1.22m)

20´ MAX. (6.2m)

 

V+H+H1= 40' MAX.(12.4m)

H+H1 = 20´ MAX. (6.2m)

V1

V+V1+H = 40' MAX.(12.4m)

 

 

 

 

 

 

V

 

 

 

H

 

H1

 

 

 

 

H

V

 

 

 

Î Figure 15. Venting with Two 90° Elbows

 

18

Hearth & Home Technologies • 6000BE, 6000BE-IPI2024-900 Rev. G • 11/05

Image 18
Contents Installation and Operation What to do if you smell gasSafety and Warning Information Table of Contents Service Parts Log Set AssemblyService Parts List 6000BE, 6000BE-IPI GLA-750TRValve Assembly Intermittent Pilot Ignition6000BE Standing Pilot IgnitionAppliance Certification High Altitude InstallationsInstallation Codes CertificationPre-install Preparation Introducing the Hearth & Home Technologies Gas FireplacesANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the 6000BE, 6000BE-IPI GAS Line AccessConstructing the Fireplace Chase Locating the FireplaceClearance Requirements Framing Dimensions Framing the FireplaceDVP90ST Tems or Components MAY be Used Installing the Vent SystemVent System Approvals Identifying Vent ComponentsFlue Restrictor Instructions Vertical VentingMAX .4 M Straight Up Vertical Venting Chart Venting with ONE 1 90 Elbow Venting with One 90 ElbowVenting with TWO 2 90 o Elbows Venting with Two 90 ElbowsVenting with Three 3 90 Elbows Venting with three 90 elbows+ V 1 FT + H 1 FT Installing Vent Components Continue Adding Vent Components To Install the Heat ShieldInstall Support Brackets Above the First 900 Elbow in the Venting System12 Hole and Vent Pipe Vent Termination Attic FirestopHorizontal Termination Service Alcove ApplicationsPositioning, Leveling, and Securing the Fireplace Proper Positioning Leveling and Securing of a FireplaceStanding Pilot Ignition System Installing the Optional Heat-Zone Kit Gas Control SystemsVice Must be Wired Directly to the FIRE- Place Junction BOX Intermittent Pilot Ignition IPI SystemPressure Natural Gas Propane Gas Supply LineGas Pressure Requirements Check for GAS LeaksOptional Accessories Wiring the FireplaceFor Standing Pilot Ignition Wiring Appliance Requirements Wall SwitchOperation using Battery Power BRNInstalling Trim, Logs, and Ember Material Installing the TrimFinishing Follow these steps Positioning the LogsShutter Settings Cover PortsGlass Assembly Placing the Ember Material6000BE Tempered 6000BE-IPI Tempered Double-check for faulty components Cold Climate SwitchBefore Lighting the Fireplace Lighting the Fireplace After the InstallationFireplace Maintenance Important Turn OFF the GAS Before Servicing Your Fireplace