Hearth and Home Technologies 6000BE owner manual Installation and Operation

Page 1

Owner’s Manual

Installation and Operation

Models:

6000BE 6000BE-IPI

Underwriters

Laboratories Listed

READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE.

WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUS- ING PROPERTY DAMAGE, PER- SONAL INJURY, OR DEATH.

-Do not store or use gasoline or other flammable vapors and liquids in the vi- cinity of this or any other appliance.

-What to do if you smell gas

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your build- ing.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

-Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

Printed in U.S.A. Copyright 2005

Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044

WARNING: IMPROPER INSTALLA- TION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAM- AGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFOR- MATION CONSULT A QUALIFIED IN- STALLER, SERVICE AGENCY, OR THE GAS SUPPLIER.

1.This appliance may be installed in an af- termarket, permanently located, manufac- tured (mobile) home, where not prohibited by local codes.

2.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

In the Commonwealth of Massachusetts:

installation must be performed by a licensed plumber or gas fitter;

a CO detector shall be installed in the room where the appliance is installed.

Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer, please call 1-888-427-3973.

Î

This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.

Hearth & Home Technologies • 6000BE, 6000BE-IPI2024-900 Rev. G • 11/05

1

Image 1
Contents What to do if you smell gas Installation and OperationSafety and Warning Information Table of Contents Log Set Assembly Service PartsGLA-750TR Service Parts List 6000BE, 6000BE-IPIIntermittent Pilot Ignition Valve AssemblyStanding Pilot Ignition 6000BEInstallation Codes High Altitude InstallationsAppliance Certification CertificationIntroducing the Hearth & Home Technologies Gas Fireplaces Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard GAS Line Access Diagram of the 6000BE, 6000BE-IPILocating the Fireplace Constructing the Fireplace ChaseClearance Requirements Framing the Fireplace Framing DimensionsDVP90ST Vent System Approvals Installing the Vent SystemTems or Components MAY be Used Identifying Vent ComponentsVertical Venting Flue Restrictor InstructionsMAX .4 M Straight Up Vertical Venting Chart Venting with One 90 Elbow Venting with ONE 1 90 ElbowVenting with Two 90 Elbows Venting with TWO 2 90 o ElbowsVenting with three 90 elbows Venting with Three 3 90 Elbows+ V 1 FT + H 1 FT Installing Vent Components Install Support Brackets To Install the Heat ShieldContinue Adding Vent Components Above the First 900 Elbow in the Venting System12 Hole and Vent Pipe Attic Firestop Vent TerminationHorizontal Termination Alcove Applications ServiceProper Positioning Leveling and Securing of a Fireplace Positioning, Leveling, and Securing the FireplaceVice Must be Wired Directly to the FIRE- Place Junction BOX Installing the Optional Heat-Zone Kit Gas Control SystemsStanding Pilot Ignition System Intermittent Pilot Ignition IPI SystemGas Pressure Requirements Gas Supply LinePressure Natural Gas Propane Check for GAS LeaksFor Standing Pilot Ignition Wiring Appliance Requirements Wiring the FireplaceOptional Accessories Wall SwitchBRN Operation using Battery PowerInstalling the Trim Installing Trim, Logs, and Ember MaterialFinishing Positioning the Logs Follow these stepsCover Ports Shutter SettingsPlacing the Ember Material Glass Assembly6000BE Tempered 6000BE-IPI Tempered Cold Climate Switch Double-check for faulty componentsBefore Lighting the Fireplace Fireplace Maintenance After the InstallationLighting the Fireplace Important Turn OFF the GAS Before Servicing Your Fireplace