Hearth and Home Technologies 6000BE owner manual Cover Ports, Shutter Settings

Page 33

5.The grate is located in the lower cav- ity. Remove the screw holding the grate in place and discard the screw.

6.Position the grate into the cutout in the refractory. Hook the grate into po- sition using the tabs on the bottom of the grate. Make sure the grate is pulled forward on the refractory (see Figure 43).

7.Cut shrink wrap and remove from around the log assembly.

!WARNING: REMOVE ALL PACKAGING FROM LOGS.

8.Install embers. See ember placement instructions for details.

!WARNING: USE DIME SIZE PIECES ONLY. DO NOT

COVER PORTS.

9.Carefully position the log set in place into the fireplace. Pull the log set for- ward until the log set contacts the log placement tabs. Center the log set in the firebox side to side (see Figure 44). (Grate removed for viewing.)

Figure 43

Log Placement Tabs

Figure 44

Shutter Settings

 

NG

LP

Burner

1/4”

5/8”

 

 

 

Hearth & Home Technologies • 6000BE, 6000BE-IPI2024-900 Rev. G • 11/05

33

Image 33
Contents What to do if you smell gas Installation and OperationSafety and Warning Information Table of Contents Log Set Assembly Service PartsGLA-750TR Service Parts List 6000BE, 6000BE-IPIIntermittent Pilot Ignition Valve AssemblyStanding Pilot Ignition 6000BEInstallation Codes High Altitude InstallationsAppliance Certification CertificationPre-install Preparation Introducing the Hearth & Home Technologies Gas FireplacesANY Such Action MAY Possibly Cause a Fire Hazard GAS Line Access Diagram of the 6000BE, 6000BE-IPIConstructing the Fireplace Chase Locating the FireplaceClearance Requirements Framing the Fireplace Framing DimensionsDVP90ST Vent System Approvals Installing the Vent SystemTems or Components MAY be Used Identifying Vent ComponentsFlue Restrictor Instructions Vertical VentingMAX .4 M Straight Up Vertical Venting Chart Venting with One 90 Elbow Venting with ONE 1 90 ElbowVenting with Two 90 Elbows Venting with TWO 2 90 o ElbowsVenting with three 90 elbows Venting with Three 3 90 Elbows+ V 1 FT + H 1 FT Installing Vent Components Install Support Brackets To Install the Heat ShieldContinue Adding Vent Components Above the First 900 Elbow in the Venting System12 Hole and Vent Pipe Vent Termination Attic FirestopHorizontal Termination Alcove Applications ServiceProper Positioning Leveling and Securing of a Fireplace Positioning, Leveling, and Securing the FireplaceVice Must be Wired Directly to the FIRE- Place Junction BOX Installing the Optional Heat-Zone Kit Gas Control SystemsStanding Pilot Ignition System Intermittent Pilot Ignition IPI SystemGas Pressure Requirements Gas Supply LinePressure Natural Gas Propane Check for GAS LeaksFor Standing Pilot Ignition Wiring Appliance Requirements Wiring the FireplaceOptional Accessories Wall SwitchBRN Operation using Battery PowerInstalling Trim, Logs, and Ember Material Installing the TrimFinishing Positioning the Logs Follow these stepsCover Ports Shutter SettingsGlass Assembly Placing the Ember Material6000BE Tempered 6000BE-IPI Tempered Double-check for faulty components Cold Climate SwitchBefore Lighting the Fireplace Fireplace Maintenance After the InstallationLighting the Fireplace Important Turn OFF the GAS Before Servicing Your Fireplace