Hearth and Home Technologies 6000BE Before Lighting the Fireplace, Cold Climate Switch

Page 35

Step 12. Before Lighting the Fireplace

Before lighting the fireplace, be sure to do the following:

Remove all paperwork from underneath the fireplace. Review safety warnings and cautions

Read the Safety and Warning Information section at the beginning of this Installers Guide.

Double-check for gas leaks

Before lighting the fireplace, double-check the unit for possible gas leaks.

Double-check vent terminations and front grilles for obstructions.

Before lighting the fireplace, double-check the unit for possible obstructions that could be blocking the vent ter- minations or the front grilles.

Double-check for faulty components

Any component that is found to be faulty MUST BE re- placed with an approved component. Tampering with the fireplace components is DANGEROUS and voids all war- ranties.

A small amount of air will be in the gas supply lines. When first lighting the fireplace, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the fireplace will light and will operate normally.

Subsequent lightings of the fireplace will not require this purging of air from the gas supply lines, unless the gas valve has been turned to the OFF position, in which case the air would have to be purged.

NOTE: The fireplace should be run 3 to 4 hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the fireplace for an additional 8 hours. This will help to cure the products used in the paint and logs.

During this break-in period it is recommended that some windows in the house be opened for air circulation. This will help avoid setting off smoke detectors, and help eliminate any odors associated with the fireplace’s initial burning.

Cold Climate Switch

If cold air infiltration, condensation, or frost on the glass is an issue due to cold climate, you may wish to operate the fireplace in cold climate mode.

To change your Intellifire ignition to be used in the cold climate mode refer to the instructions included with the kit.

Hearth & Home Technologies • 6000BE, 6000BE-IPI2024-900 Rev. G • 11/05

35

Image 35
Contents What to do if you smell gas Installation and OperationSafety and Warning Information Table of Contents Log Set Assembly Service PartsGLA-750TR Service Parts List 6000BE, 6000BE-IPIIntermittent Pilot Ignition Valve AssemblyStanding Pilot Ignition 6000BECertification High Altitude InstallationsInstallation Codes Appliance CertificationANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Hearth & Home Technologies Gas Fireplaces GAS Line Access Diagram of the 6000BE, 6000BE-IPIClearance Requirements Constructing the Fireplace ChaseLocating the Fireplace Framing the Fireplace Framing DimensionsDVP90ST Identifying Vent Components Installing the Vent SystemVent System Approvals Tems or Components MAY be UsedMAX .4 M Straight Up Vertical Venting Flue Restrictor InstructionsVertical Venting Chart Venting with One 90 Elbow Venting with ONE 1 90 ElbowVenting with Two 90 Elbows Venting with TWO 2 90 o ElbowsVenting with three 90 elbows Venting with Three 3 90 Elbows+ V 1 FT + H 1 FT Installing Vent Components Above the First 900 Elbow in the Venting System To Install the Heat ShieldInstall Support Brackets Continue Adding Vent Components12 Hole and Vent Pipe Horizontal Termination Vent TerminationAttic Firestop Alcove Applications ServiceProper Positioning Leveling and Securing of a Fireplace Positioning, Leveling, and Securing the FireplaceIntermittent Pilot Ignition IPI System Installing the Optional Heat-Zone Kit Gas Control SystemsVice Must be Wired Directly to the FIRE- Place Junction BOX Standing Pilot Ignition SystemCheck for GAS Leaks Gas Supply LineGas Pressure Requirements Pressure Natural Gas PropaneWall Switch Wiring the FireplaceFor Standing Pilot Ignition Wiring Appliance Requirements Optional AccessoriesBRN Operation using Battery PowerFinishing Installing Trim, Logs, and Ember MaterialInstalling the Trim Positioning the Logs Follow these stepsCover Ports Shutter Settings6000BE Tempered 6000BE-IPI Tempered Glass AssemblyPlacing the Ember Material Before Lighting the Fireplace Double-check for faulty componentsCold Climate Switch Important Turn OFF the GAS Before Servicing Your Fireplace After the InstallationFireplace Maintenance Lighting the Fireplace