Hearth and Home Technologies 6000BE owner manual Follow these steps, Positioning the Logs

Page 32

Positioning the Logs

!BEFORE

FIRING THE UNIT

Follow these steps:

1.Release four glass clips and set the glass assembly aside.

CAUTION: The log assembly is fragile. Handle with care.

NOTE: See Step 9 when replacing the log set in an existing fireplace.

Figure 40

2.Carefully cut the cable tie holding the log assembly in place and discard the tie. Do not leave any part of the tie in the fireplace (see Figure 41).

WARNING: USE WIRE CUT- ! TERS. DO NOT ATTEMPT TO CUT THE TIE WITH A KNIFE.

3. Grasp the log assembly by the ends. Do NOT grasp the log as- sembly by the center. Remove the log assembly from the fireplace and set aside.

4. Remove the foam pad from the fire- place and discard. Make sure all piec- es of the foam are removed. With a screwdriver bend up the log place- ment tabs (see Figure 42).

Figure 41

Log Placement Tabs

Figure 42

32

Hearth & Home Technologies • 6000BE, 6000BE-IPI2024-900 Rev. G • 11/05

Image 32
Contents Installation and Operation What to do if you smell gasSafety and Warning Information Table of Contents Service Parts Log Set AssemblyService Parts List 6000BE, 6000BE-IPI GLA-750TRValve Assembly Intermittent Pilot Ignition6000BE Standing Pilot IgnitionHigh Altitude Installations Installation CodesAppliance Certification CertificationANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Hearth & Home Technologies Gas Fireplaces Diagram of the 6000BE, 6000BE-IPI GAS Line AccessClearance Requirements Constructing the Fireplace ChaseLocating the Fireplace Framing Dimensions Framing the FireplaceDVP90ST Installing the Vent System Vent System ApprovalsTems or Components MAY be Used Identifying Vent ComponentsMAX .4 M Straight Up Vertical Venting Flue Restrictor InstructionsVertical Venting Chart Venting with ONE 1 90 Elbow Venting with One 90 ElbowVenting with TWO 2 90 o Elbows Venting with Two 90 ElbowsVenting with Three 3 90 Elbows Venting with three 90 elbows+ V 1 FT + H 1 FT Installing Vent Components To Install the Heat Shield Install Support BracketsContinue Adding Vent Components Above the First 900 Elbow in the Venting System12 Hole and Vent Pipe Horizontal Termination Vent TerminationAttic Firestop Service Alcove ApplicationsPositioning, Leveling, and Securing the Fireplace Proper Positioning Leveling and Securing of a FireplaceInstalling the Optional Heat-Zone Kit Gas Control Systems Vice Must be Wired Directly to the FIRE- Place Junction BOXStanding Pilot Ignition System Intermittent Pilot Ignition IPI SystemGas Supply Line Gas Pressure RequirementsPressure Natural Gas Propane Check for GAS LeaksWiring the Fireplace For Standing Pilot Ignition Wiring Appliance RequirementsOptional Accessories Wall SwitchOperation using Battery Power BRNFinishing Installing Trim, Logs, and Ember MaterialInstalling the Trim Follow these steps Positioning the LogsShutter Settings Cover Ports6000BE Tempered 6000BE-IPI Tempered Glass AssemblyPlacing the Ember Material Before Lighting the Fireplace Double-check for faulty componentsCold Climate Switch After the Installation Fireplace MaintenanceLighting the Fireplace Important Turn OFF the GAS Before Servicing Your Fireplace