Placing the Ember Material

Ember material is shipped with this gas fireplace. To place the ember material:

Pull the four glass latches out of the groove on the glass frame. Remove glass door from the unit (see Figure 45).

LATCHES

(BOTH BOTTOM

AND TOP)

GLASS

ASSEMBLY

Figure 45.

Glass Assembly

Embers CANNOT be placed directly over ports. Care should be taken not to cover the lighting trail of ports (from back to front).

When placing Glowing embers onto the burner care should be taken so that the ports are not covered. Place the embers along side the port trail, but not on or in between the ports (see Figure 46). Failure to follow this procedure will likely cause lighting and sooting problems.

Place Mystic embers on areas of base refractory away from port holes. Use this material to give your fireplace a realistic ash bed.

Save the remaining ember materials for use during fire- place servicing.

Replace the glass door and a front trim door on the unit.

Pull out and latch the glass clips into the groove on the glass frame.

EMBER MATERIAL

Figure 46. Placement of the Ember Material

Glass Specifications:

6000BE: TEMPERED

6000BE-IPI: TEMPERED

Hearth & Home Technologies fireplaces manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defined by the CPSC. The tempered glass has been tested and certified to the require- ments ofANSI Z97.1-1984 and CPSC 16 CFR 1202. (Safety Glazing Certification Council SGCC # 1595 and 1597. Ar- chitectural Testing, Inc. Reports 02-31919.01 and 02- 31917.01.)

This statement is in compliance with SPCS 16 CFR Sec- tion 1201.5 “Certification and labeling requirements” which refers to 15 USC 2063 stating “…Such certificate shall ac- company the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please con- tact your dealer or distributor to order.

34

Hearth & Home Technologies • 6000BE, 6000BE-IPI2024-900 Rev. G • 11/05

Image 34
Contents Installation and Operation What to do if you smell gasSafety and Warning Information Table of Contents Service Parts Log Set AssemblyService Parts List 6000BE, 6000BE-IPI GLA-750TRValve Assembly Intermittent Pilot Ignition6000BE Standing Pilot IgnitionAppliance Certification High Altitude InstallationsInstallation Codes CertificationIntroducing the Hearth & Home Technologies Gas Fireplaces Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the 6000BE, 6000BE-IPI GAS Line AccessLocating the Fireplace Constructing the Fireplace ChaseClearance Requirements Framing Dimensions Framing the FireplaceDVP90ST Tems or Components MAY be Used Installing the Vent SystemVent System Approvals Identifying Vent ComponentsVertical Venting Flue Restrictor InstructionsMAX .4 M Straight Up Vertical Venting Chart Venting with ONE 1 90 Elbow Venting with One 90 ElbowVenting with TWO 2 90 o Elbows Venting with Two 90 ElbowsVenting with Three 3 90 Elbows Venting with three 90 elbows+ V 1 FT + H 1 FT Installing Vent Components Continue Adding Vent Components To Install the Heat ShieldInstall Support Brackets Above the First 900 Elbow in the Venting System12 Hole and Vent Pipe Attic Firestop Vent TerminationHorizontal Termination Service Alcove ApplicationsPositioning, Leveling, and Securing the Fireplace Proper Positioning Leveling and Securing of a FireplaceStanding Pilot Ignition System Installing the Optional Heat-Zone Kit Gas Control SystemsVice Must be Wired Directly to the FIRE- Place Junction BOX Intermittent Pilot Ignition IPI SystemPressure Natural Gas Propane Gas Supply LineGas Pressure Requirements Check for GAS LeaksOptional Accessories Wiring the FireplaceFor Standing Pilot Ignition Wiring Appliance Requirements Wall SwitchOperation using Battery Power BRNInstalling the Trim Installing Trim, Logs, and Ember MaterialFinishing Follow these steps Positioning the LogsShutter Settings Cover PortsPlacing the Ember Material Glass Assembly6000BE Tempered 6000BE-IPI Tempered Cold Climate Switch Double-check for faulty componentsBefore Lighting the Fireplace Lighting the Fireplace After the InstallationFireplace Maintenance Important Turn OFF the GAS Before Servicing Your Fireplace