6.The complete installation must comply with local codes or in the absence of local codes, with National Fuel Gas code ANSI Z223.1/NFPA54, or The National Propane Gas Installation Code CSA B149.1 as applicable.
VENTILATION REQUIREMENTS AND RECOMMENDATIONS
Ventilation unit | Standard Counter | Island Installation |
Hood Size | 24” Deep x Unit Width | 30” Deep x unit width |
Blower Size | 48” Range |
|
| ||
| 36” Range |
|
| ||
| 30” Range |
|
| 500 CFM | 500CFM |
•When installing a range with a grill, select a blower on the high end of the recommendation.
•Hood blower speeds should be variable to reduce noise and loss of heated or air conditioned air.
•The elimination of smoke and cooking vapors is best when the hood is installed 30” to 36” above the range cooktop.
•Wood covered hoods should be installed 36” above the range cooktop. o For Sauté /
above the range top is 32”
Consult a professional heating and ventilating contractor for local code information on single and double wall ducting requirements.
INSTALLING THE ANTI-TIP DEVICE
FOLLOW ENCLOSED SEPARATE INSTRUCTIONS
1.All ranges must have an
2.If you pull the range out from the wall for any reason, make sure that the
3.There is the possible risk of the range tipping over and causing injury if the open oven door is leaned on when the
When Installation is complete, check to be sure that the range installation is correct by checking the