GE 10-95 CG warranty Installation Instructions, Before YOU Begin

Page 35
NOT LESS THAN WIDTH OF RANGE

INSTALLATION INSTRUCTIONS

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT: Save these instructions for the local electrical inspector’s use.

IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES.

NOTE TO INSTALLER: Leave these instructions with the appliance after installation is completed.

NOTE TO CONSUMER: Keep this Use and Care Guide and Installation Instructions for future use.

NOTE: This appliance must be properly grounded.

TOOLS YOU WILL NEED

Large blade screwdriver

Channel lock pliers or small ratchet wrench with 3/16-inch socket (for leveling range)

1/4-inch hex head nutdriver

ELECTRICAL REQUIREMENTS

CAUTION, FOR PERSONAL SAFETY:

DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.

REMOVE HOUSE FUSE OR OPEN CIRCUIT BREAKER BEFORE BEGINNING INSTALLATION.

This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or time delay fuse, as noted on the rating plate.

Wiring must conform to National Electric Codes.

If the electric service provided does not meet the above specifications, it is recommended that a licensed electrician install an approved outlet.

Because range terminals are not accessible after the range is in position, flexible service conduit or cord must be used.

STEP 1

PREPARE THE OPENING

112 inch spacing is recommended from the range to adjacent vertical walls above cooktop surface.

Allow 30 inches minimum clearance between surface units and bottom of unprotected wood or metal top cabinet, and 15 inches minimum between countertop and adjacent cabinet bottom.

EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.

To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a min. of 5 inches beyond the bottom of the cabinets. Make sure the wall coverings, countertops and cabinets around the range, oven or cooktop can withstand heat generated by the range up to 200°F.

 

 

 

 

 

 

 

HOOD

 

 

 

 

 

 

 

 

5MIN.

30

 

 

 

 

 

 

 

 

MIN. 15

 

 

 

 

 

 

 

 

MIN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOCATE

 

 

 

 

 

 

 

 

OUTLET BOX

WALL

 

 

 

 

 

 

WITHIN EITHER

 

 

 

 

 

 

 

SHADED AREA

 

1

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

MIN.

 

 

 

 

 

INSTALL

 

 

 

 

 

 

 

 

OUTLET BOX

 

 

 

 

 

 

 

ON EITHER

WALL

C OF RANGE

 

 

 

SIDE OF C

 

 

 

L

 

 

 

 

L

 

 

7

1 2

 

 

 

 

 

 

 

 

 

 

 

OUTLET

7

7

1 2

1458

 

 

 

 

BOX

 

 

3

1

2

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

1 4

 

 

 

 

 

 

 

CORD FLOOR

Anti-Tip Bracket (install in either rear corner)

(continued next page)

35

Image 35
Contents UseandCare& Installation Guide If you received Damaged range… Save time and money. Before you request service…Help US Help YOU… Important Safety Instructions Important Safety InstructionsOven Self-Cleaning OvenCooktop and Radiant Surface Units Save These InstructionsJBP79 Features of Your RangeFeatures of Your Range Type of Cooktop Description How It Works Radiant HOW does this Cooktop Compare To Your OLD ONE?General Information About Radiant Surface Units Cooktop ComparisonSurface Controls How to Set the ControlsDual Surface Unit Switch Cooking Guide for Using Heat SettingsSpecial Notes for Glass Cooktops Hot Surface Indicator LightSurface Controls Porcelain/enamel Surface Cookware TipsTypes of Cookware Copper BottomResistant, not scratch proof How to Check Pan PerformanceSurface Flat-bottomed canners are required for glass cooktops Home Canning TipsObserve the Following Points in Canning Canning should be done on the cooktop onlyHome Canning Tips Glass Cooktop CleaningCleaning Glass Cooktop CleaningBroil Bake Features of Your Oven ControlOven Control Oven CONTROL, Clock and TimerFeatures of Your Clock and TimerShelf Positions Using Your OvenBefore Using Your Oven Oven ShelvesBaking UsingBaking Your OvenCookies Pan PlacementBaking Pans Baking GuidesDon’t Peek How to Time BakeHow to Set Immediate Start and Automatic Stop Timed BakingQuick Reminder How to Set Delay Start and Automatic StopTimed Baking Adjust the Oven Thermostat Adjust the Oven ThermostatUse of Aluminum Foil RoastingFor Frozen Roasts Questions and AnswersWhy is my roast crumbling when I try to carve it? Roasting GuideShould I salt the meat before broiling? Why are my meats not turning out as brown as they should?Broiling Oven door should be open to the broil stop position Broiling GuideBroiling Before a Clean Cycle Operating the SELF-CLEANING OvenTo Stop a Clean Cycle Cleaning OvenHow to Set the Oven for Cleaning After a Clean CycleHow to Set Delay Start of Cleaning Care Care and CleaningOperating the Self-Cleaning Oven Glass Window Control Panel and KnobsCooktop Surface Light Metal PartsOven Heating Elements Care and CleaningLift-Off Oven Door Sure Grip HandleAfter broiling, remove How to Remove the Storage Drawer to Clean Under the RangeOven Light Replacement Broiler Pan and GridBefore YOU Begin Installation InstructionsStep Step Wire Power Cord Installation Step Wire Conduit Installation Step Final Check Problem Possible Cause QUESTIONS? USE this Problem SolverAfter Clean Cycle Problem SolverIf YOU Need Service Problem SolverNeed Problem Solver If YouService ServicesWarranty

10-95 CG specifications

The GE 10-95 CG is a notable locomotive designed to meet the demands of freight transport with efficiency and reliability. Built by General Electric, this model showcases a combination of advanced technology and impressive engineering, making it a prominent choice in the rail industry.

One of the primary features of the GE 10-95 CG is its powerful diesel engine. The locomotive is equipped with a 12-cylinder 7FDL engine, capable of producing substantial horsepower that allows it to handle heavy loads across challenging terrains. This engine configuration not only provides reliability but also ensures operational efficiency, allowing for lower fuel consumption over longer distances.

The 10-95 CG is recognized for its distinct, rugged design that is built to withstand diverse environmental conditions. Its robust frame and sturdy body contribute to its longevity and durability, while the optimized aerodynamics reduce drag, enhancing fuel efficiency. The locomotive's structure is designed for easy access and maintenance, allowing operators to keep it in optimal working condition with minimal downtime.

In terms of technologies, the GE 10-95 CG integrates advanced electronic systems that enhance performance and monitoring. The locomotive features a sophisticated microprocessor-based control system that enables precise engine management, ensuring optimal operation under varying conditions. Additionally, the use of dynamic braking technology provides enhanced control, reducing wear and tear on the braking system while improving safety.

The traction system of the GE 10-95 CG employs alternating current (AC) traction motors, which are known for their efficiency and reduced maintenance requirements compared to traditional DC motors. This technology results in better acceleration and overall performance, making the locomotive adept in both hauling heavy freight and navigating tight curves.

Another notable characteristic of the GE 10-95 CG is its ability to operate in multiple unit configurations. This allows for seamless coupling with other locomotives, enabling operators to scale their freight capacity as needed. The versatility of this locomotive makes it a valuable asset in various rail operations.

In summary, the GE 10-95 CG embodies a blend of power, efficiency, and advanced technology. With features designed for durability, operational efficiency, and ease of maintenance, it stands out as a formidable choice for freight transportation in the rail industry. Its innovative systems and robust performance characteristics ensure that it remains a reliable solution for meeting the demands of modern logistics and transportation.