2. TYPICAL INSTALLATIONS (CONT’D)
2.2INSTALLATION FOR HEPA 4000 ONLY (CONT’D) 2.2.2 HEPA 4000 ATTIC INSTALLATION
All 3 types of installation can be used in the attic (Stand Alone, Central Draw Point or
CAUTION
Due to the potential temperature difference between the attic and the rest of the house, all unit ducts must be insulated.
CAUTION
The attic temperature must always be above 0°C (32°F).
A portion of stale air is exhausted to the outside and the rest is drawn to the unit. Outside fresh air is blended with interior air and then filtered. This filtered air is supplied to the return (plenum) of the forced air unit.
To avoid the
See figure below.
NOTE: Home with multiple forced air systems should have 1 unit on each system.
VH0051 |
CAUTION |
Do not connect the HEPA 4000 on any forced air system supply duct. Connect it only to the air return duct. Do not install duct or duct connector directly above the forced air unit or not less than 9’10’’ (3 m) of the plenum connection to the forced air unit, as measured along the length of the duct.
- 11 -