6. MAINTENANCE

!WARNING

0

Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source.

6.1BIANNUAL MAINTENANCE (ESSENTIAL)

If your unit is equipped with an optionnal wall control (C12 / CM or C34 / CMR) you should perform this maintenance when the Filter Maintenance light is flashing. Otherwise, this maintenance must be performed every 6 months to ensure your unit proper operation for years to come. Follow these steps:

1.Turn switch knob to OFF to unlock the door.

2.Unlatch the door and open it. Clean the inner side of the door with a clean damp cloth, them wipe with a dry one.

3.Slide out the air diffuser (HEPA 2000 and HF 2.0 units only), the recovery core (HEPA 3000 and HF 3.0 units only), the energy recovery core (HEPA 4000 units only) and the filter cartridge from the unit.

NOTES: 1. On HEPA 2000 and HF 2.0 only, never grab the white shaft (item 2) to pull out the air diffuser.

2.To remove the filter cartridge, pull on its tabs (item 5).

2

1

VD0107

1)Air diffuser

2)White Shaft

3

VD0091

3) Heat Recovery Core

4

5

VD0155

4) Energy recovery Core

VD0112

5) Filter Cartridge Tabs

- 34 -

Image 34
Contents Installation Instructions About this Manual About These Units Table of Contents Table DES Matières Typical Installations Before StartingTypical Installations CONT’D Hepa 1000 and HF 1.0 Unit Installations CONT’D RETURN-RETURN Installation Connection to a Forced AIR System Hepa 4000 Restricted Area VH0051 Hepa 2000, HF 2.0, Hepa 3000, HF 3.0 and Hepa Hepa 2000, HF 2.0, Hepa 3000, HF 3.0 and Hepa 4000 Unit VH0043 Dimensions Front View TOP ViewDimensions CONT’D Install the Unit Install the Unit CONT’D HOW to Hang the Unit CONT’D Stale air exhaust ductwork Stale air ductwork Filtered air ductwork Return side connection cont’d Hepa 2000, HF2.0, Hepa 3000, HF 3.0 and Hepa 4000 Units only Pull back the insulation to expose the flexible duct 457 mm Xmas tree pin Connecting the Drain Hepa 3000 and HF 3.0 Units only Controls NORMAL/REMOTEControls CONT’D Controls C12 / CM and C34 / CMRControls C12 / CM and C34 / CMR CONT’D VD0088 Is on Normal or Boost Using C34 / CMR Control Maintenance Maintenance CONT’D For Hepa 2000 and HF 2.0 onlyMaster Reset C12 / CM and C34 / CMR Controls Parts Ordering Chart Troubleshooting Problems Solutions