4. INSTALL THE UNIT

4.1LOCATING AND MOUNTING THE UNIT

Choose an appropriate location for the unit.

Within an area of the house where the ambiant temperature is between 10°C (50°F) and 65°C (149°F) (basement, furnace room, closet, etc.).

So as to provide easy access to the interior of the unit, for filter maintenance.

Close to an exterior wall, so as to limit the length of the insulated flexible duct to and from the unit (not necessary for HEPA 1000 and HF 1.0 units).

Away from hot chimneys and other fire hazards.

Allow for a power source (standard 3-prong grounding outlet).

Close to a drain. If no drain is close by, use a pail to collect run-off. (for HEPA 3000 and HF 3.0 units only).

Here are the tools and materials needed to perform the installation:

-Phillips screwdriver #2 or Robertson #1

-Hammer and flat blade screwdriver (for plenum connection installation only, to make holes in existing metal duct)

-Scissors or utility knife (to cut duct tape)

-Duct tape

-Tin snips or metal shear (for plenum connection installation only, to cut ductwork)

-Aluminum duct tape (for plenum connection installation only)

-Jig saw (except for the HEPA 1000 unit)

-Caulking gun and caulking (except for HEPA 1000 and HF 1.0 units)

4.2MOUNT THE PORTS ON THE UNIT

Mount the 8” oval ports and the 5” to 6” oval ports on the top of the unit using the screws provided in the hardware box (4 screws #8 x 3/4” long per port).

NOTES: 1. The HEPA 1000 and the HF 1.0 units don’t have the 5” to 6” oval ports.

2.If an optional wall control has to be installed, do not install the front 8’’ oval port at this time.

VO0018

- 17 -

Image 17
Contents Installation Instructions About this Manual About These Units Table of Contents Table DES Matières Before Starting Typical InstallationsTypical Installations CONT’D Hepa 1000 and HF 1.0 Unit Installations CONT’D RETURN-RETURN Installation Connection to a Forced AIR System Hepa 4000 Restricted Area VH0051 Hepa 2000, HF 2.0, Hepa 3000, HF 3.0 and Hepa Hepa 2000, HF 2.0, Hepa 3000, HF 3.0 and Hepa 4000 Unit VH0043 Front View TOP View DimensionsDimensions CONT’D Install the Unit Install the Unit CONT’D HOW to Hang the Unit CONT’D Stale air exhaust ductwork Stale air ductwork Filtered air ductwork Return side connection cont’d Hepa 2000, HF2.0, Hepa 3000, HF 3.0 and Hepa 4000 Units only Pull back the insulation to expose the flexible duct 457 mm Xmas tree pin Connecting the Drain Hepa 3000 and HF 3.0 Units only NORMAL/REMOTE ControlsControls C12 / CM and C34 / CMR Controls CONT’DControls C12 / CM and C34 / CMR CONT’D VD0088 Is on Normal or Boost Using C34 / CMR Control Maintenance For Hepa 2000 and HF 2.0 only Maintenance CONT’DMaster Reset C12 / CM and C34 / CMR Controls Parts Ordering Chart Problems Solutions Troubleshooting