Broan HEPA 1000, HEPA 4000, HEPA 3000, HEPA 2000 HOW to Hang the Unit CONT’D

Page 19

4.INSTALL THE UNIT (CONT’D)

4.3HOW TO HANG THE UNIT (CONTD)

Turn the switch knob to OFF position in order to unlock the door. Unlatch the door and open it. Using a screwdriver, remove the 2 retaining screws of the front plate and carefully remove the front plate from the unit.

VO0019

Insert the 4 hooks in the square holes and fix them to the unit using 4 screws #8 - 32 x 3/4”.

NOTE: If an optional wall controll has to be installed, go to Section 5.0 on pages 29 to 31. If not, continue the installation.

Reinstall the front plate and close the door.

VO0020

Hang the unit to the floor joist, using 4 #8 x 1 1/2” screws, 4 chains and 4 spings. See following illustration.

VD0077

4.4PLANNING OF THE DUCTWORK

Keep it simple. Plan for a minimum of bends and joints.

Keep the length of outside insulated duct to a minimum (not for HEPA 1000).

Do not ventilate crawl spaces or cold rooms. Do not attempt to recover the exhaust air from a dryer or a range hood. This would cause clogging of the filters and recovery module (if applicable).

If the house has two floors or more, be sure to plan for at least one exhaust register on the highest lived-in level.

- 19 -

Image 19
Contents Installation Instructions About this Manual About These Units Table of Contents Table DES Matières Before Starting Typical InstallationsTypical Installations CONT’D Hepa 1000 and HF 1.0 Unit Installations CONT’D RETURN-RETURN Installation Connection to a Forced AIR System Hepa 4000 Restricted Area VH0051 Hepa 2000, HF 2.0, Hepa 3000, HF 3.0 and Hepa Hepa 2000, HF 2.0, Hepa 3000, HF 3.0 and Hepa 4000 Unit VH0043 Front View TOP View DimensionsDimensions CONT’D Install the Unit Install the Unit CONT’D HOW to Hang the Unit CONT’D Stale air exhaust ductwork Stale air ductwork Filtered air ductwork Return side connection cont’d Hepa 2000, HF2.0, Hepa 3000, HF 3.0 and Hepa 4000 Units only Pull back the insulation to expose the flexible duct 457 mm Xmas tree pin Connecting the Drain Hepa 3000 and HF 3.0 Units only NORMAL/REMOTE ControlsControls C12 / CM and C34 / CMR Controls CONT’DControls C12 / CM and C34 / CMR CONT’D VD0088 Is on Normal or Boost Using C34 / CMR Control Maintenance For Hepa 2000 and HF 2.0 only Maintenance CONT’DMaster Reset C12 / CM and C34 / CMR Controls Parts Ordering Chart Problems Solutions Troubleshooting