Broan HEPA 2000, HEPA 4000, HEPA 3000, HEPA 1000 Before Starting, Typical Installations

Page 6

1. BEFORE STARTING

1.1INSPECT THE CONTENTS OF THE BOXES

!WARNING

0

To avoid risk of suffocation, discard the plastic bag wrapping the unit.

Inspect the exterior of the unit for shipping damage. Ensure that there is no damage to the door, door latches, main switch, etc.

CAUTION

Remove the cardboard strip inside the unit (if applicable).

Inspect the interior of the unit for damage. Ensure that blower assembly, heat recovery core (HEPA 3000 et HF 3.0), energy recovery core (HEPA 4000), insulation, dampers (HEPA 2000, HF 2.0, HEPA 3000, HF 3.0 and HEPA 4000), prefilter, HEPA filter, etc. are all intact.

2.TYPICAL INSTALLATIONS

Installations may vary according to the model number and the position in which the unit is installed. Use the following illustrations as guidelines to help you decide on how your unit will be installed.

All the units should be hung to the joist, and installed either vertically or horizontally. NOTE: For more details, see Point 5.3 in Section 5 INSTALL THE UNIT.

In every case, bathroom fans and a range hood should be used to exhaust stale air. Also, for homes with more than one level, we recommend one exhaust register at the highest level.

There are 3 installation methods: Stand Alone, Central Draw Point and Return-to- Return Installation.

NOTE: An electrical outlet has to be available within 3 feet from the unit.

- 6 -

Image 6
Contents Installation Instructions About this Manual About These Units Table of Contents Table DES Matières Typical Installations Before StartingTypical Installations CONT’D Hepa 1000 and HF 1.0 Unit Installations CONT’D RETURN-RETURN Installation Connection to a Forced AIR System Hepa 4000 Restricted Area VH0051 Hepa 2000, HF 2.0, Hepa 3000, HF 3.0 and Hepa Hepa 2000, HF 2.0, Hepa 3000, HF 3.0 and Hepa 4000 Unit VH0043 Dimensions Front View TOP ViewDimensions CONT’D Install the Unit Install the Unit CONT’D HOW to Hang the Unit CONT’D Stale air exhaust ductwork Stale air ductwork Filtered air ductwork Return side connection cont’d Hepa 2000, HF2.0, Hepa 3000, HF 3.0 and Hepa 4000 Units only Pull back the insulation to expose the flexible duct 457 mm Xmas tree pin Connecting the Drain Hepa 3000 and HF 3.0 Units only Controls NORMAL/REMOTEControls CONT’D Controls C12 / CM and C34 / CMRControls C12 / CM and C34 / CMR CONT’D VD0088 Is on Normal or Boost Using C34 / CMR Control Maintenance Maintenance CONT’D For Hepa 2000 and HF 2.0 onlyMaster Reset C12 / CM and C34 / CMR Controls Parts Ordering Chart Troubleshooting Problems Solutions