4. INSTALL THE UNIT (CONT’D)

4.8CONNECTING THE DRAIN (HEPA 3000 AND HF 3.0 UNITS ONLY)

1

1

VO0025

1

2

3

VO0046

2

1.Remove the door by turning the switch knob to the OFF position (to unlock the door).Then, unlatch the door and open it. Slide out the core assembly to access the 2 drain fitting hole locations (1). Punch out the holes.

2.Hand tighten the 2 plastic drain fittings (1) using the gaskets (2) and nuts (3) as shown. Close the door.

27''

 

686 mm

 

 

7''

 

(178 mm)

VO0027

3

 

3.Cut 2 sections of plastic tubing; one 7’’ (178 mm) long and one 27’’ (686 mm) long, and attach them to each drain fitting as shown.

5. Make a water trap loop in the tube to prevent the unit from drawing unpleaseant odors from the drain source. Make sure this loop is situated BELOW the ‘’T’’ as shown. This will prevent water from being drawn back up into the unit in case of negative pressure. Run the tube to the floor drain or an alternative drain pipe or pail. Be sure there is a slight slope for the run-off.

VO0028

4

4.Join these 2 sections to the ‘’T’’ junction and main tube as shown.

Tie-wrap

 

VO0029 To drain

5

- 27 -

Image 27
Contents Installation Instructions About this Manual About These Units Table of Contents Table DES Matières Before Starting Typical InstallationsTypical Installations CONT’D Hepa 1000 and HF 1.0 Unit Installations CONT’D RETURN-RETURN Installation Connection to a Forced AIR System Hepa 4000 Restricted Area VH0051 Hepa 2000, HF 2.0, Hepa 3000, HF 3.0 and Hepa Hepa 2000, HF 2.0, Hepa 3000, HF 3.0 and Hepa 4000 Unit VH0043 Front View TOP View DimensionsDimensions CONT’D Install the Unit Install the Unit CONT’D HOW to Hang the Unit CONT’D Stale air exhaust ductwork Stale air ductwork Filtered air ductwork Return side connection cont’d Hepa 2000, HF2.0, Hepa 3000, HF 3.0 and Hepa 4000 Units only Pull back the insulation to expose the flexible duct 457 mm Xmas tree pin Connecting the Drain Hepa 3000 and HF 3.0 Units only NORMAL/REMOTE ControlsControls C12 / CM and C34 / CMR Controls CONT’DControls C12 / CM and C34 / CMR CONT’D VD0088 Is on Normal or Boost Using C34 / CMR Control Maintenance For Hepa 2000 and HF 2.0 only Maintenance CONT’DMaster Reset C12 / CM and C34 / CMR Controls Parts Ordering Chart Problems Solutions Troubleshooting