8. TROUBLESHOOTING
| PROBLEMS | SOLUTIONS |
|
|
| • Check breaker or fuse in main |
|
|
| distribution panel. |
|
|
| • Check there is 120V at the |
|
|
| electrical outlet. |
|
|
| • Make sure the unit main switch is |
|
| 1.Unit does not start at Normal | properly set in Normal or Boost |
|
| or Boost position. | position. |
|
|
| • If a wall control (C12 / CM or |
|
|
| C34 / CMR) is connected, |
|
|
| disconnect control wire from the |
|
|
| unit, then make sure the unit |
|
|
| main switch is properly set in |
|
|
| Normal or Boost position. |
|
|
| • If a wall control (C12 / CM or |
|
| 2. Unit does not run at Normal | C34 / CMR) is used, disconnect |
|
| speed, but runs at Boost. | control wire from the unit. Then, if |
|
|
| the unit runs at Normal speed, |
|
|
| chech control wiring and wall |
|
|
| control connections. |
|
| 3. Unit is not operating as per | • Check if the unit main switch is in |
|
| “Normal/Remote” position. |
| |
| the selected mode. |
| |
| • Check wall control wiring. |
| |
|
|
| |
| 4. Wall control indicators do not work | • Check wall control wiring. |
|
| properly or not at all. |
|
|
| 5. On C34 / CMR wall control only, 1 or | • Check if the unit main switch is in |
|
| 2 light indicators are flashing | “Normal/Remote” position. |
|
| every second. | • Check wall control wiring. |
|
|
|
|
|
If the problem is still not solved, call your installer or the nearest approved Service Center.