FIGURE 11

COMBINATION AIR BOOT ASSEMBLY

COMBUSTION

AIR BOOT

ASSEMBLY

INTAKE AIR TUBE

USE THIS

KNOCKOUT

FOR OIL LINE

BURNER

ASSEMBLY

REMOVE PUMP TO

ASSEMBLE INNER

AIR BOOT

REMOVE KNOCKOUT

IN LEFT SIDE

INSERT OUTER AIR

BOOT AND SECURE

FLANGE TO UNIT

MAKE ALL SETTINGS

MIS-1833

ACCORDING TO MANUAL

FOR AIR BOOT.

Manual 2100-422 Page 21

Image 23
Contents OIL Furnace Installation Instructions Contents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsMinimum Clearances Equipment SelectionLocating the Furnace Specification Sheet Supply Specification Sheet FC085 Model Dimensions Specification SheetInstallation Installing the FurnaceInstalling a Cooling Unit Instruments Required for Proper Setup of the FurnaceElectrical Data WiringFactory Wiring Field WiringTypical Unit Setup FLF Unit Shown I m n e y Beckett AFG OIL Burner Typical Single Inside Tank InstallationOIL Line Piping Beckett R7184B Primary Control Beckett Cleancut OIL PumpBeckett Solid State Igniter Beckett R7184B Primary Operational Guide Electronic Blower Control Cleaner ConnectionPreparation Steps Burner Setup and Adjustment ProceduresFurnace Data Combustion Diagnosis Combustion Adjustment StepsSmoke Test Short Form Adjustment ProcedureFinal Checks Check DraftTypical Smoke CO2 Chart with Adjustment Range High Air Settings Low Bacharach Smoke NumberPressure Gauge Connection to Bleed Port Correlation of Percent of CO2, O2 Reserve AIR No Fuel OIL Efficiency Chart NET Stack TEMP. Degrees FRecommended START-UP Settings Combustion AIR Requirements GUN Assembly AdjustmentRemoving GUN Assembly Electrode AdjustmentsCombination AIR Boot Assembly Combustion AIR Boot AssemblyALL AIR from Inside Building Appliances Located in Confined SpacesSquare Feet Required to Qualify AS Unconfined Space Appliances Located in Confined Spaces ALL AIR from Outdoors Minimum Ventilation OpeningsALL Ventilation AIR from Outdoors MIS-1338 Vertical Venting Louvers and GrillesVenting Options Thermostat200 Filter Sizes for OIL Furnaces Typical Installation of FR26 FR27 Filter RacksTypical Installation of FR25 Filter KIT LO-BOY Models Filter Locations Filter Installation LO-BOY ModelsFinal Inspection and Test Service HintsLubrication Inspect AIR FilterRemoval of Burner only Combination Combustion CHAMBER/BURNER Mounting SystemRemoval of Entire Combustion Chamber Mounting System To Remove Burner onlyTo Remove the Entire Combustion Chamber Mounting System Care of Finish Cleaning of the Heat ExchangerCommon Causes of Trouble Chart FLF/FLR085D36E Data Chart FH085D36E DataChart FH110D48E Data Chart FH110D60E DataChart FC085D36E Data Chart FLR140D60E DataUnit FH Series Wiring DiagramCond Cond Unit