321 Studios FH110D60E, FLF110D48E, FH110D48E, FLR140D60E warranty Typical Unit Setup FLF Unit Shown

Page 10

WARNING

ALL WIRING MUST

CONFORM TO THE ! NATIONAL ELECTRIC

CODE AND ALL LOCAL

CODES.

FIGURE 4

TYPICAL UNIT SETUP

FLF UNIT SHOWN

Left side high voltage (unit power) entrance

Left side low voltage (thermostat) entrance

Left side oil line entrance for opt. air boot

Left side oil line entrance

Oil line (see burner pump inst. for hookup info.)

Air Boot knockout (optional)

Control panel (junction box in FH units)

Right side high voltage

(unit power)

entranceRight side oil line

entrance

Inspection door

Right side low voltage (thermostat) entrance

To thermostat and optional A/C unit

To power source

Shut off switch (if not fused, power line must include fuse or circuit breaker)

Power Wires:

Black (HOT)

White (NEUTRAL)

Green (GROUND)

MIS-1836

Manual 2100-422

Page 8

Image 10
Contents OIL Furnace Installation Instructions Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersLocating the Furnace Equipment SelectionMinimum Clearances Specification Sheet Supply Specification Sheet Specification Sheet FC085 Model DimensionsInstruments Required for Proper Setup of the Furnace Installing the FurnaceInstalling a Cooling Unit InstallationField Wiring WiringFactory Wiring Electrical DataTypical Unit Setup FLF Unit Shown I m n e y OIL Line Piping Typical Single Inside Tank InstallationBeckett AFG OIL Burner Beckett Solid State Igniter Beckett Cleancut OIL PumpBeckett R7184B Primary Control Beckett R7184B Primary Operational Guide Cleaner Connection Electronic Blower ControlFurnace Data Burner Setup and Adjustment ProceduresPreparation Steps Combustion Adjustment Steps Combustion DiagnosisCheck Draft Short Form Adjustment ProcedureFinal Checks Smoke TestHigh Air Settings Low Bacharach Smoke Number Typical Smoke CO2 Chart with Adjustment RangePressure Gauge Connection to Bleed Port Recommended START-UP Settings No Fuel OIL Efficiency Chart NET Stack TEMP. Degrees FCorrelation of Percent of CO2, O2 Reserve AIR Electrode Adjustments GUN Assembly AdjustmentRemoving GUN Assembly Combustion AIR RequirementsCombustion AIR Boot Assembly Combination AIR Boot AssemblySquare Feet Required to Qualify AS Unconfined Space Appliances Located in Confined SpacesALL AIR from Inside Building ALL Ventilation AIR from Outdoors Minimum Ventilation OpeningsAppliances Located in Confined Spaces ALL AIR from Outdoors MIS-1338 Thermostat Louvers and GrillesVenting Options Vertical Venting200 Typical Installation of FR25 Filter KIT Typical Installation of FR26 FR27 Filter RacksFilter Sizes for OIL Furnaces Filter Installation LO-BOY Models LO-BOY Models Filter LocationsInspect AIR Filter Service HintsLubrication Final Inspection and TestCombination Combustion CHAMBER/BURNER Mounting System Removal of Burner onlyTo Remove the Entire Combustion Chamber Mounting System To Remove Burner onlyRemoval of Entire Combustion Chamber Mounting System Common Causes of Trouble Cleaning of the Heat ExchangerCare of Finish Chart FH110D60E Data Chart FH085D36E DataChart FH110D48E Data Chart FLF/FLR085D36E DataChart FLR140D60E Data Chart FC085D36E DataFH Series Wiring Diagram UnitCond Cond Unit