321 Studios FLF085D36E, FLF110D48E, FH110D48E warranty Chart FLR140D60E Data, Chart FC085D36E Data

Page 36

CHART 7

FLR140D60E DATA

Blower Speed

 

Blower Static

 

Low

.05

.14

.17

.24

Medium Low

.08

.17

.22

.30

 

 

 

 

 

Medium High

.11

.20

.27

.35

 

 

 

 

 

High

.20

.30

.40

.50

 

 

 

 

 

CHART 8

FC085D36E DATA

Blower Speed

 

Blower Static

 

Low

.08

.14

.20

.26

 

 

 

 

 

Medium

.16

.24

.36

.42

 

 

 

 

 

High

.20

.30

.40

.50

 

 

 

 

 

Manual 2100-422

Page 34

Image 36
Contents OIL Furnace Installation Instructions Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersEquipment Selection Locating the FurnaceMinimum Clearances Specification Sheet Supply Specification Sheet Specification Sheet FC085 Model DimensionsInstalling the Furnace Installing a Cooling UnitInstruments Required for Proper Setup of the Furnace InstallationWiring Factory WiringField Wiring Electrical DataTypical Unit Setup FLF Unit Shown I m n e y Typical Single Inside Tank Installation OIL Line PipingBeckett AFG OIL Burner Beckett Cleancut OIL Pump Beckett Solid State IgniterBeckett R7184B Primary Control Beckett R7184B Primary Operational Guide Cleaner Connection Electronic Blower ControlBurner Setup and Adjustment Procedures Furnace DataPreparation Steps Combustion Adjustment Steps Combustion DiagnosisShort Form Adjustment Procedure Final ChecksCheck Draft Smoke TestHigh Air Settings Low Bacharach Smoke Number Typical Smoke CO2 Chart with Adjustment RangePressure Gauge Connection to Bleed Port No Fuel OIL Efficiency Chart NET Stack TEMP. Degrees F Recommended START-UP SettingsCorrelation of Percent of CO2, O2 Reserve AIR GUN Assembly Adjustment Removing GUN AssemblyElectrode Adjustments Combustion AIR RequirementsCombustion AIR Boot Assembly Combination AIR Boot AssemblyAppliances Located in Confined Spaces Square Feet Required to Qualify AS Unconfined SpaceALL AIR from Inside Building Minimum Ventilation Openings ALL Ventilation AIR from OutdoorsAppliances Located in Confined Spaces ALL AIR from Outdoors MIS-1338 Louvers and Grilles Venting OptionsThermostat Vertical Venting200 Typical Installation of FR26 FR27 Filter Racks Typical Installation of FR25 Filter KITFilter Sizes for OIL Furnaces Filter Installation LO-BOY Models LO-BOY Models Filter LocationsService Hints LubricationInspect AIR Filter Final Inspection and TestCombination Combustion CHAMBER/BURNER Mounting System Removal of Burner onlyTo Remove Burner only To Remove the Entire Combustion Chamber Mounting SystemRemoval of Entire Combustion Chamber Mounting System Cleaning of the Heat Exchanger Common Causes of TroubleCare of Finish Chart FH085D36E Data Chart FH110D48E DataChart FH110D60E Data Chart FLF/FLR085D36E DataChart FLR140D60E Data Chart FC085D36E DataFH Series Wiring Diagram UnitCond Cond Unit