321 Studios FH110D60E, FLF110D48E, FH110D48E warranty Correlation of Percent of CO2, O2 Reserve AIR

Page 21

TABLE 5

CORRELATION OF PERCENT OF CO2, O2

AND RESERVE AIR

Carbon

Oxygen

Reserve Air

Dioxide

(Approx.)

 

 

 

 

15.4

0.0

0.0

15.0

0.6

3.0

14.5

1.2

6.0

14.0

2.0

10.0

13.5

2.6

15.0

13.0

3.3

20.0

12.5

4.0

25.0

12.0

4.6

30.0

11.5

5.3

35.0

11.0

6.0

40.0

10.5

6.7

45.0

10.0

7.4

50.0

TABLE 6

NO. 2 FUEL OIL EFFICIENCY CHART (NET STACK TEMP. DEGREES F)

% O2

200

250

300

350

400

450

500

550

600

650

700

750

800

% O2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

89.6

88.4

87.3

86.2

85.1

84.0

82.9

81.7

80.6

79.5

78.4

77.3

76.2

14.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

89.4

88.2

87.0

85.9

84.7

83.6

82.4

81.2

80.1

78.9

77.7

76.6

75.4

14.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

89.2

87.9

86.7

85.5

84.3

83.1

81.9

80.7

79.4

78.2

77.0

75.8

74.6

13.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

88.9

87.7

86.4

85.1

83.8

82.6

81.3

80.0

78.7

77.5

76.2

74.9

73.6

12.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

88.7

87.3

86.0

84.6

83.3

82.0

80.6

79.3

77.9

76.6

75.3

73.9

72.6

11.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

88.4

87.0

85.5

84.1

82.7

81.3

79.9

78.5

77.0

75.6

74.2

72.8

71.4

11.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

88.0

86.5

85.0

83.5

82.0

80.5

79.0

77.5

76.0

74.5

73.0

71.5

70.0

10.3

TABLE 7

RECOMMENDED START-UP SETTINGS

 

 

Factory Installed

 

Field Installed Option

 

 

 

 

Air

Air

 

Air

Air

 

Air

Air

Furnace

Burner Style

1

Band

Shutter

1

Band

Shutter

1

Band

Shutter

Model No.

Part No.

Nozzle

Setting

Setting

Nozzle

Setting

Setting

Nozzle

Setting

Setting

FH085D36E

AFG/9020-026

.75

0

6

.65

0

5

.55

0

5

 

 

 

 

 

 

 

 

 

 

 

FH110D48E

AFG/9020-027

1.00

2

10

.85

0

8

NA

NA

NA

 

 

 

 

 

 

 

 

 

 

 

FH110D60E

AFG/9020-027

1.00

2

10

.85

0

8

NA

NA

NA

 

 

 

 

 

 

 

 

 

 

 

FLF085D36E

AFG/9020-026

.75

0

6

.65

0

5

.55

0

5

 

 

 

 

 

 

 

 

 

 

 

FLF110D48E

AFG/9020-027

1.00

2

10

.85

0

8

NA

NA

NA

FLF110D60E

 

 

 

 

 

 

 

 

 

 

FLR085D36E

AFG/9020-031

.75

0

6

.65

0

5

.55

0

5

 

 

 

 

 

 

 

 

 

 

 

FLR110D48E

AFG/9020-032

1.00

2

10

.85

0

8

NA

NA

NA

FLR110D60E

 

 

 

 

 

 

 

 

 

 

FLR140D60E

AFG/9020-033

1.25

0

8

1.10

0

6

NA

NA

NA

FC085D36E

AFG/9020-026

.75

0

6

.65

0

5

.55

0

5

 

 

 

 

 

 

 

 

 

 

 

j70 degree hollow cone spray pattern, 100 PSIG pump pressure

Manual 2100-422 Page 19

Image 21
Contents OIL Furnace Installation Instructions Contents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsEquipment Selection Locating the FurnaceMinimum Clearances Specification Sheet Supply Specification Sheet FC085 Model Dimensions Specification SheetInstalling a Cooling Unit Installing the FurnaceInstruments Required for Proper Setup of the Furnace InstallationFactory Wiring WiringField Wiring Electrical DataTypical Unit Setup FLF Unit Shown I m n e y Typical Single Inside Tank Installation OIL Line PipingBeckett AFG OIL Burner Beckett Cleancut OIL Pump Beckett Solid State IgniterBeckett R7184B Primary Control Beckett R7184B Primary Operational Guide Electronic Blower Control Cleaner ConnectionBurner Setup and Adjustment Procedures Furnace DataPreparation Steps Combustion Diagnosis Combustion Adjustment StepsFinal Checks Short Form Adjustment ProcedureCheck Draft Smoke TestTypical Smoke CO2 Chart with Adjustment Range High Air Settings Low Bacharach Smoke NumberPressure Gauge Connection to Bleed Port No Fuel OIL Efficiency Chart NET Stack TEMP. Degrees F Recommended START-UP SettingsCorrelation of Percent of CO2, O2 Reserve AIR Removing GUN Assembly GUN Assembly AdjustmentElectrode Adjustments Combustion AIR RequirementsCombination AIR Boot Assembly Combustion AIR Boot AssemblyAppliances Located in Confined Spaces Square Feet Required to Qualify AS Unconfined SpaceALL AIR from Inside Building Minimum Ventilation Openings ALL Ventilation AIR from OutdoorsAppliances Located in Confined Spaces ALL AIR from Outdoors MIS-1338 Venting Options Louvers and GrillesThermostat Vertical Venting200 Typical Installation of FR26 FR27 Filter Racks Typical Installation of FR25 Filter KITFilter Sizes for OIL Furnaces LO-BOY Models Filter Locations Filter Installation LO-BOY ModelsLubrication Service HintsInspect AIR Filter Final Inspection and TestRemoval of Burner only Combination Combustion CHAMBER/BURNER Mounting SystemTo Remove Burner only To Remove the Entire Combustion Chamber Mounting SystemRemoval of Entire Combustion Chamber Mounting System Cleaning of the Heat Exchanger Common Causes of TroubleCare of Finish Chart FH110D48E Data Chart FH085D36E DataChart FH110D60E Data Chart FLF/FLR085D36E DataChart FC085D36E Data Chart FLR140D60E DataUnit FH Series Wiring DiagramCond Cond Unit