A. Introduction

The Models AP40BC250-12, AP40BC250-2-12, BCCP-1, BCCP-2, and BCIP Blast Chillers are used to rapidly chill cooked foods to temperatures suitable for storage in a refrigerator. Blast chillers are sophisticated refrigeration machines capable of lowering the core temperature of most foods from 160°F to 38°F in less than two hours. Blast chilling operations employ high velocity cooled air flow to assure even cooling of the entire food product, and to quickly bring the food temperature through the danger zone in which bacteria multiply rapidly. This is done in accordance with HACCP, FDA and all state regulations. A dual temperature chilling cycle allows use of standard recipes without modification.

A.1. Controller Features

A solid state electronic controller, conveniently mounted on the front panel of the unit, is used to program and to operate the unit. Full controller instructions follow, covering:

initial set-up (done at time of installation)

programming of the cycles (done before operation and changed only if foods or conditions are changed)

operator selection from several available choices of operating mode

operation

The versatility of the controller allows the operator to choose from the following modes and cycles:

1.AUTOMATIC MODE, the preferred mode, in which all the food probes are active and take part in controlling the chilling process. The cycle will never proceed to its next step until all the probes have reached their set temperatures. The operator needs only to select the recipe number of the food to be controlled by each probe (up to 150 recipes can be programmed), then insert each probe into its food. When all the probes have reached their programmed temperatures, the unit will automatically switch into holding mode.

2.MANUAL MODE, in which operating time is manually set by the operator for a particular meal. Air temperature is controlled by the air probes. The food probes, if they have been inserted into the food, will provide temperature readouts only. Manual mode will also switch automatically into the holding mode at the end of the cycle.

3.DEFROST CYCLE, used to defrost the unit if there has been a build-up of ice.

4.UV CYCLE (OPTIONAL), for sanitizing the unit.

5.PRINTER (OPTIONAL), which may be programmed to print or not print during the chilling cycles. If the printer is selected, printing starts automatically at the beginning of each chill cycle. All the operating parameters (starts and stops of the chilling cycle, dates and times, air and food temperatures) are printed, and then repeated in accordance with the programmed printer cycle time. If the printer is not selected, the readings will be stored for printing at a later time (up to 250 events, corresponding to one week of normal usage, can be stored). Refer to the instructions in this manual, as well as in the printer’s manual, for more details.

NOTE: Be certain to complete and return the printer’s warranty card. Also retain the ribbon & paper order form for use when needed.

2

Image 4
Contents E-mail service@americanpanel.com American Panel Corporation5800 S.E. 78th Street, Ocala, Florida Phone 352 245-7055 Fax 352 REV. C5800 S.E. 78 th Street, Ocala, Florida Phone 352 245-7055 Fax 352 “Our reputation rests on the steadfast pursuit of your satisfaction”INDEX IndexINTRODUCTION A. IntroductionCONTROLLER INSTALLATION B. InstallationB.2. Single Unit Installation AP40BC250-12 And BCCP-1 INSTALLATION PHOTO #2 DRAWING # PHOTO #3 B.2.3. Electrical Connections COLOR CODE CHART PLUG/CONNECTORPLUG/CONNECTOR DESTINATION CABLE/WIREPHOTO #4 PHOTO #5 PHOTO #6 PHOTO #7 Door magnetic switch on the left Magnet on the right PHOTO #8i CABINET C. Refrigeration Unit Installationii AIR COOLED electrical power supplies FIG # VERIFYING CORRECT INSTALLATION CONDENSATE DRAINAGE CONNECTIONPROGRAMMING D. Programming The Controller WARNINGSPREPARATION Automatic ModeD.3. Programming Modes a three button combination using , , , , . For example, press PROGRAMMING PROGRAMMING PROGRAMMING PROGRAMMING D.5.4. Parameter Programming For UV Cycle The Parameter Programming is now complete E. Printer Optional PROGRAMMING OPERATING F. Operating And Maintaining The UnitPanning LoadingThe food temperature screen air temperature screenthe food temperature screen air temperature screenOPERATING F.2.6. Error Messages And Troubleshooting MAINTENANCE Daily CleaningPreventive Maintenance As needed WarningsWARRANTY contractor. It is not covered by this WarrantyAPPENDIXES AppendixesAUTO MANUALAppendix 2 Electrical Schematic Appendix 3 Electrical Schematic Description PartNumber ƒ Click on Sales & Service ƒ Click on Dealer Locator Appendix 5 Ordering Printer Supplies Ribbon & PaperAmerican Panel Corporation E-mail service@americanpanel.com5800 S.E. 78th Street, Ocala, Florida Phone 352 245-7055 Fax 352