American Panel AP40BC250-2-12, BCCP-1, BCIP, BCCP-2, AP40BC250-12 manual Installation

Page 8
Manual background

INSTALLATION

B.2.2. Install Fan Assembly Frame

1.Insert the fan assembly frame into the door hinge side of the box with the fans facing the interior of the box (see DRAWING # 4). Push the assembly tight to the side wall leaving ¼” space at the front and rear panels.

Note the three holes on the stainless steel angle frame (at the top of the horizontal cross brace on the vertical surface at the back of the frame). Drill 1/8” pilot holes into the back panel of the box.

2. Secure the frame to the back of the box with self-tapping 8/32” stainless steel screws (see DRAWING # 3, page 5)

DRAWING # 4

6

Image 8
Contents E-mail service@americanpanel.com American Panel Corporation5800 S.E. 78th Street, Ocala, Florida Phone 352 245-7055 Fax 352 REV. C5800 S.E. 78 th Street, Ocala, Florida Phone 352 245-7055 Fax 352 “Our reputation rests on the steadfast pursuit of your satisfaction”INDEX IndexINTRODUCTION A. IntroductionCONTROLLER INSTALLATION B. InstallationB.2. Single Unit Installation AP40BC250-12 And BCCP-1 INSTALLATION PHOTO #2 DRAWING # PHOTO #3 B.2.3. Electrical Connections COLOR CODE CHART PLUG/CONNECTORPLUG/CONNECTOR DESTINATION CABLE/WIREPHOTO #4 PHOTO #5 PHOTO #6 PHOTO #7 Door magnetic switch on the left Magnet on the right PHOTO #8ii AIR COOLED C. Refrigeration Unit Installationi CABINET electrical power supplies FIG # VERIFYING CORRECT INSTALLATION CONDENSATE DRAINAGE CONNECTIONPROGRAMMING D. Programming The Controller WARNINGSPREPARATION Automatic ModeD.3. Programming Modes a three button combination using , , , , . For example, press PROGRAMMING PROGRAMMING PROGRAMMING PROGRAMMING D.5.4. Parameter Programming For UV Cycle The Parameter Programming is now complete E. Printer Optional PROGRAMMING OPERATING F. Operating And Maintaining The UnitPanning LoadingThe food temperature screen air temperature screenthe food temperature screen air temperature screenOPERATING F.2.6. Error Messages And Troubleshooting MAINTENANCE Daily CleaningPreventive Maintenance As needed WarningsWARRANTY contractor. It is not covered by this WarrantyAPPENDIXES AppendixesAUTO MANUALAppendix 2 Electrical Schematic Appendix 3 Electrical Schematic Number PartDescription ƒ Click on Sales & Service ƒ Click on Dealer Locator Appendix 5 Ordering Printer Supplies Ribbon & Paper5800 S.E. 78th Street, Ocala, Florida Phone 352 245-7055 Fax 352 E-mail service@americanpanel.comAmerican Panel Corporation