1. AUTOMATIC MODE - SOFT CHILL

a.With the display reading "OFF", press the 1. AUTOMATIC MODE - SOFT CHILL (“ON/OFF”) button.

OFF

b. To select the soft cycle, press the appropriate button

OPERATING MODE

 

. The LED for "SOFT" will be steady "ON".

CHOOSE

 

OPERATING CYCLE

 

 

 

 

c.The LED's for “AUTOMATIC” and “MANUAL” are

now blinking. To select an “AUTOMATIC” cycle,

SOFT CYCLE

press the button

. The LED for

CHOOSE MODE

AUTO / MAN

“AUTOMATIC” will now be steady "ON".

 

 

d.To choose your recipe, press Manual background or Manual background then

press Manual background.

RED FOOD PROBE

ENTER RECIPE NUMBER

1

CHICKEN

1 Blinks

e.To choose your recipe, press Manual background or Manual background then

press Manual background.

YELLOW FOOD PROBE ENTER RECIPE NUMBER 2

ROAST BEEF

2 Blinks

f.To choose your recipe, press Manual background or Manual background then

press Manual background.

BLUE FOOD PROBE

ENTER RECIPE NUMBER

1

CHICKEN

1 Blinks

g.To choose your recipe, press Manual background or Manual background then

press Manual background.

GREEN FOOD PROBE

ENTER RECIPE NUMBER

2

ROAST BEEF

2 Blinks

NOTE:

This screen is shown only if the RECIPE parameter is set to “ON” in the INITIAL PROGRAMMING. A 4 food probe configuration is shown.

The red food probe only will be active in the standard configuration.

To enter additional recipe names, refer to Page 25 "RECIPE NAME PROGRAMMING".

26

Image 27
Contents USER’S MANUAL American Panel CorporationREV. E E-mail service@americanpanel.comINSTALLATION AT THE SAME LEVEL CONTROLLER FEATURESINSTALLATION OF REMOTE UNITS REQUIREMENTS TO BE MET DURING INSTALLATION 8 STEPSCLEANING THE CONDENSER PREPARING AND USING THE OPTIONAL PRINTERMAINTENANCE MAINTENANCE AND CLEANINGCONTROLLER FEATURES INTRODUCTIONOPERATING MODES OPERATING CYCLES PRINTER OPTIONALPC CONNECTION OPTIONAL COMPRESSOR INSTALLATION OF REMOTE UNITSREQUIREMENTS TO BE MET DURING INSTALLATION 8 STEPS INSTALLATION AT THE SAME LEVELCONNECTION PIPING FOR REMOTE CONDENSING UNITS INSTALLATION AT DIFFERENT LEVELSWARNINGS INSTALLATIONINSTALLATION DIMENSIONSCONDENSATE DRAINAGE CONNECTION VERIFYING CORRECT INSTALLATIONELECTRICAL AND REFRIGERATION SPECIFICATIONS CONNECTION TO THE REMOTE UNITSPACES AROUND THE CABINET STARTING & TESTING THE UNITSOFT CHILL CYCLE USING THE HURRICHILL TECHNOLOGYBLAST CHILLING SHOCK FREEZINGPANNING AND LOADING PANNINGLOADING CONTROL PANEL FOR MODELS AP24 & AP40 BLAST CHILLERS / SHOCK FREEZERS PROGRAMMING KEYS KEYBOARD KEYSKEY COMBINATIONS ON/OFF & START/STOP1. INITIAL PROGRAMMING c. Enter the default password by pressing, in order, theIf the entered password is wrong the display will show PROGRAMMINGThe high air alarm temperature should be left at The low air alarm temperature should be left atThe high food alarm temperature should be left at NO for blast chillers AP24BC250-3, AP40BC350-3 and go to step r The low food alarm temperature should be left atThe P.C. baud rate should be left at YES for shock freezers AP24BCF300-3, AP40BCF450-32. PROGRAMMING THE CYCLES AUTOMATIC HARD CYCLE PARAMETERS PROGRAMMING AUTOMATIC SOFT CYCLE PARAMETERS PROGRAMMINGp. To change the temperature, press AUTOMATIC SHOCK CYCLE PARAMETERS PROGRAMMINGk. To change the temperature, press then pressUV LIGHT CYCLE PARAMETERS PROGRAMMING aa. Press DEFROST CYCLE PARAMETERS PROGRAMMINGHEATED PROBE CYCLE PARAMETERS PROGRAMMING The defrost type must be left AIR FLOWhh. To change the temperature, press MANUAL SOFT CYCLE PARAMETERS PROGRAMMINGgg. Press The LED for SOFT will be steadyMANUAL HARD CYCLE PARAMETERS PROGRAMMING MANUAL SHOCK CYCLE PARAMETERS PROGRAMMING 3. RECIPE NAME PROGRAMMING 1. AUTOMATIC MODE - SOFT CHILL OPERATION2. MANUAL MODE - SOFT CHILL alternating withalternating 3. HARD CHILL CYCLE a. To perform a UV cycle remove all food, then press 4. SHOCK FREEZE CYCLE5. UV STERILIZATION CYCLE 6. DEFROST CYCLEdefrost cycle 7. HEATED FOOD PROBEb. Open the door c. Press theOTE To stop any cycle before it has finished, press START/STOP 8. PREPARING AND USING THE OPTIONAL PRINTER9. TO CLEAR DATA d. Enter your password, then pressNOTE The optional printer is delivered fully installed PRINTEROPERATING THE PRINTER MAINTENANCELOADING A ROLL OF PAPER REMOVING A ROLL OF PAPERMAINTENANCE AND CLEANING CLEANING THE CONDENSERREPLACING THE RIBBON WITH PAPER IN THE PRINTER DO NOT USE ABRASIVES, SOLVENTS WIRING DIAGRAMSCLEANING COMPARTMENTAP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual COMPUTER CONNECTION PARTS LIST PART #DESCRIPTION BLAST CHILLERS / SHOCK FREEZERS ONLY STANDARD WARRANTYinstalling contractor. It is not covered by this Warranty AMERICAN PANEL CORPORDERING PRINTER SUPPLIES RIBBON & PAPER