Transition Networks RS-232-TO-100BASE-FX manual Compliance information, Compliances, Regulations

Page 80

Transition Networks

SDSFE31xx-100 Industrial Device Server

Compliance information

Compliances

CISPR22/EN5022 Class A + EN55024; EN60950 Class A; FCC Class A; CE Mark

FCC

 

This equipment has been tested and found to comply with the limits for a Class A

Regulations

digital device, pursuant to part 15 of the FCC rules. These limits are designed to

 

provide reasonable protection against harmful interference when the equipment is

 

operated in a commercial environment. This equipment generates, uses, and can

 

radiate radio frequency energy and, if not installed and used in accordance with the

 

instruction manual, may cause harmful interference to radio communications.

 

Operation of this equipment in a residential area is likely to cause harmful

 

interference, in which case the user will be required to correct the interference at the

 

user’s own expense.

Canadian

 

This digital apparatus does not exceed the Class A limits for radio noise for digital

Regulations

apparatus set out on the radio interference regulations of the Canadian Department of

 

Communications. Le présent appareil numérique n'émet pas de bruits

 

radioélectriques dépassant les limites applicables aux appareils numériques de la

 

Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le

 

ministère des Communications du Canada.

European Regulations

CUATION:

This is a Class A product. In a domestic environment, this product could cause radio interference in which case the user may be required to take adequate corrective measures.

Achtung !

Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich.

Attention !

Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.

Continued on next page

68

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

Image 80
Contents Page Page Table of Contents Transition Networks Iii Intentionally Blank May be required to take adequate preventative measures Trademark Copyright restrictions FCC warningCE Mark About this product and manual Box contents The box should include the following About this product and manualObserve this caution could result in EMI problems Equipment, or injury to personsDamage to the Device Server PerformanceSDSFE31xx-100 Industrial Device Server Transition Networks Intentionally Blank Section SDSFE31xx-100 Industrial Device Server This section These are the topicsTopic SeeOverview FeaturesGeneral description SDSFE31xx-100 Industrial part numbers StandardPhysical description PartsFunctions FunctionsPhysical description Device server parts and functionsIntentionally Blank Section Installation This sectionThese are the topics Topic SeeDevice Service mounting location DIN rail clip and DIN rail mounting Mounted DIN Rail ClipDIN rail clip and DIN rail mounting Step ActionGrounding the Device Server Device Server Grounding ScrewConnecting power to the Device Server Redundant Power ConnectionsConnecting power to the Device Server Turn the external power source OFFStrip the power wires as required Polarity. See FigureTerminal-block plug wiring Step Action Wired Terminal-Block Plug Inserted Into Device ServerConnecting an alarm fixture Alarm Relay ContactsIndications Connecting an alarm fixtureFault Connecting fiber cables Fiber Cable ConnectionsConnecting DB-9 cable InstallationSection for DB-9 cable pinouts DB-9 cableDIP Switches Dip Switch Settings and ExplanationsIntentionally Blank Section Operations Light emitting diodes LEDs LEDsDevice Server configuration Login Dialog BoxDevice Server configuration Web accessConfiguration software System RestartConfiguration software System information submenu Master information submenuConfiguration menu options Serial Port Transfer Configuration Submenu DisplaySerial port config submenu Submenu Item Description Serial Device Connection to a Host via Ethernet NetworkSerial Tunneling RS-232 Port Connection Status Submenu Display Submenu Item DescriptionSee Figure User configSubmenu Firmware Upgrade Submenu FW upgrade via Http Step Action Http Firmware File Name CapturedFW upgrade via Http Index Page System information DisplayFW upgrade via Tftp Step Action Configuration System Backup File Display Backup File Restore Display Snmp configuration menu Snmp communities submenu Snmp Communities DisplayDescribes the fields on the IP Trap Manager display IP Trap Parameters and DescriptionsIP trap manager submenu System restore System RestoreReset Will be erasedIntentionally Blank This are the topics Section Serial IP Redirector SoftwareSection Serial IP redirect software description What is Needed? Step ActionInstalling serial IP redirector software Installation Wizard Dialog BoxInstalling serial IP redirector software Software Destination Folder Dialog BoxSelect Features Dialog Box Ready to Install Application Dialog Box Step Action Software upgrades Upgrading serial IP redirector softwareCreating virtual COM ports Serial IP Control Panel Dialog BoxCreating virtual COM ports Select Ports Dialog BoxVirtual Port Configuration COM Port 7 Configuration Wizard Setting button will be active. See Figure If the wizardFails If the wizard isIf the wizard is successful Step Action Serial/IP Port MonitorIntroduction Section TroubleshootingTroubleshooting problem and corrective action table Troubleshooting problem and corrective action table Problem Potential Cause Potential SolutionSection Cable Specifications This section provides copper and fiber cable specificationsCopper DB-9 RS-232serial cable specifications What is RS-232Specifications PinoutsFiber Cable Specifications Fiber cable and optic specificationsParameterSpecification Intentionally Blank Section Contact Us, Warranty Conformity Information Contact us Conformity declaration Declaration of ConformityWarranty Warranty Compliance information CompliancesRegulations CanadianCompliance information Accordance with European Union Directive 2002/96/ECPortion of this document To the Public Telephone NETWORK. Failure to observe thisIntentionally Blank Parameter Description Appendix a Technical SpecificationSDSFES31xx-100 specifications, notices, and warnings SDSFES31xx-100 specifications, notices, and warnings Subchapter J applicable at the date of manufactureCould result in damage to equipment This warning could result in an eye injury or blindnessCOM Port Configuration IndexPacket Mode